Cargando…
Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry
Laparoscopic surgery (LS) has been shown to provide great benefits to patients compared with open surgery. However, surgeons experience discomfort, low-efficiency, and even musculoskeletal disorders (MSDs) because of the poor ergonomic design of laparoscopic instruments. A methodology for the ergono...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9916209/ https://www.ncbi.nlm.nih.gov/pubmed/36767729 http://dx.doi.org/10.3390/ijerph20032361 |
_version_ | 1784886071135305728 |
---|---|
author | Du, Yujia Jiang, Rui Wang, Haining |
author_facet | Du, Yujia Jiang, Rui Wang, Haining |
author_sort | Du, Yujia |
collection | PubMed |
description | Laparoscopic surgery (LS) has been shown to provide great benefits to patients compared with open surgery. However, surgeons experience discomfort, low-efficiency, and even musculoskeletal disorders (MSDs) because of the poor ergonomic design of laparoscopic instruments. A methodology for the ergonomic design of laparoscopic dissector handles considering three-dimensional (3D) hand anthropometry and dynamic hand positions was addressed in this research. Two types of hand positions for grasping and stretching were scanned from 21 volunteers using a high-resolution 3D scanner. The 3D anthropometric data were extracted from these 3D hand pose models and used to design an improved handle (IH) that provides additional support for the thumb, a better fit to the purlicue, and a more flexible grasp for the index finger. Thirty subjects were invited to evaluate the IH in terms of muscular effort, goniometric study of motion, and efficiency and effectiveness during four trials of a laparoscopic training task. Questionnaires provided subjective parameters for ergonomic assessment. Positive results included less muscle load in the trapezius as well as significant but small angular differences in the upper limb. No significant reduction in the trial time and no increased percentage of the achievement were observed between the IH and the commercial handle (CH). Improved intuitiveness, comfort, precision, stability, and overall satisfaction were reported. IH provides significant ergonomic advantages in laparoscopic training tasks, demonstrating that the proposed methodology based on 3D anthropometry is a powerful tool for the handle design of laparoscopic dissectors and other surgical instruments. |
format | Online Article Text |
id | pubmed-9916209 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99162092023-02-11 Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry Du, Yujia Jiang, Rui Wang, Haining Int J Environ Res Public Health Article Laparoscopic surgery (LS) has been shown to provide great benefits to patients compared with open surgery. However, surgeons experience discomfort, low-efficiency, and even musculoskeletal disorders (MSDs) because of the poor ergonomic design of laparoscopic instruments. A methodology for the ergonomic design of laparoscopic dissector handles considering three-dimensional (3D) hand anthropometry and dynamic hand positions was addressed in this research. Two types of hand positions for grasping and stretching were scanned from 21 volunteers using a high-resolution 3D scanner. The 3D anthropometric data were extracted from these 3D hand pose models and used to design an improved handle (IH) that provides additional support for the thumb, a better fit to the purlicue, and a more flexible grasp for the index finger. Thirty subjects were invited to evaluate the IH in terms of muscular effort, goniometric study of motion, and efficiency and effectiveness during four trials of a laparoscopic training task. Questionnaires provided subjective parameters for ergonomic assessment. Positive results included less muscle load in the trapezius as well as significant but small angular differences in the upper limb. No significant reduction in the trial time and no increased percentage of the achievement were observed between the IH and the commercial handle (CH). Improved intuitiveness, comfort, precision, stability, and overall satisfaction were reported. IH provides significant ergonomic advantages in laparoscopic training tasks, demonstrating that the proposed methodology based on 3D anthropometry is a powerful tool for the handle design of laparoscopic dissectors and other surgical instruments. MDPI 2023-01-29 /pmc/articles/PMC9916209/ /pubmed/36767729 http://dx.doi.org/10.3390/ijerph20032361 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Du, Yujia Jiang, Rui Wang, Haining Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry |
title | Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry |
title_full | Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry |
title_fullStr | Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry |
title_full_unstemmed | Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry |
title_short | Ergonomic Design and Assessment of an Improved Handle for a Laparoscopic Dissector Based on 3D Anthropometry |
title_sort | ergonomic design and assessment of an improved handle for a laparoscopic dissector based on 3d anthropometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9916209/ https://www.ncbi.nlm.nih.gov/pubmed/36767729 http://dx.doi.org/10.3390/ijerph20032361 |
work_keys_str_mv | AT duyujia ergonomicdesignandassessmentofanimprovedhandleforalaparoscopicdissectorbasedon3danthropometry AT jiangrui ergonomicdesignandassessmentofanimprovedhandleforalaparoscopicdissectorbasedon3danthropometry AT wanghaining ergonomicdesignandassessmentofanimprovedhandleforalaparoscopicdissectorbasedon3danthropometry |