Cargando…

Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography

The Inverse Method is a widely used technique for the determination of adsorption isotherms in liquid chromatography. In this method, isotherm is determined from the overloaded peak profile of the component by the iterative solution of the mass balance equation of liquid chromatography. Successful u...

Descripción completa

Detalles Bibliográficos
Autores principales: Horváth, Szabolcs, Lukács, Diána, Farsang, Evelin, Horváth, Krisztián
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919363/
https://www.ncbi.nlm.nih.gov/pubmed/36770697
http://dx.doi.org/10.3390/molecules28031031
_version_ 1784886806181838848
author Horváth, Szabolcs
Lukács, Diána
Farsang, Evelin
Horváth, Krisztián
author_facet Horváth, Szabolcs
Lukács, Diána
Farsang, Evelin
Horváth, Krisztián
author_sort Horváth, Szabolcs
collection PubMed
description The Inverse Method is a widely used technique for the determination of adsorption isotherms in liquid chromatography. In this method, isotherm is determined from the overloaded peak profile of the component by the iterative solution of the mass balance equation of liquid chromatography. Successful use of this method requires a prior assumption of equation of isotherm (Langmuir, BET etc.). In this work, we have developed an inverse method that gives results of similar accuracy to the frontal analysis without assuming the equation of the isotherm. The oversaturated peaks were calculated using a spline fitted to data points instead of the derivative of the isotherm. The distribution of the isotherm points were optimized for minimizing the difference between the measured and calculated overloaded peaks. The accuracy of the developed method was verified with synthetic benchmark peaks and by the determination of isotherm of buthyl-benzoate under real conditions. The results confirmed that the accuracy of the developed method is similar to that of Frontal Analysis.
format Online
Article
Text
id pubmed-9919363
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99193632023-02-12 Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography Horváth, Szabolcs Lukács, Diána Farsang, Evelin Horváth, Krisztián Molecules Article The Inverse Method is a widely used technique for the determination of adsorption isotherms in liquid chromatography. In this method, isotherm is determined from the overloaded peak profile of the component by the iterative solution of the mass balance equation of liquid chromatography. Successful use of this method requires a prior assumption of equation of isotherm (Langmuir, BET etc.). In this work, we have developed an inverse method that gives results of similar accuracy to the frontal analysis without assuming the equation of the isotherm. The oversaturated peaks were calculated using a spline fitted to data points instead of the derivative of the isotherm. The distribution of the isotherm points were optimized for minimizing the difference between the measured and calculated overloaded peaks. The accuracy of the developed method was verified with synthetic benchmark peaks and by the determination of isotherm of buthyl-benzoate under real conditions. The results confirmed that the accuracy of the developed method is similar to that of Frontal Analysis. MDPI 2023-01-19 /pmc/articles/PMC9919363/ /pubmed/36770697 http://dx.doi.org/10.3390/molecules28031031 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Horváth, Szabolcs
Lukács, Diána
Farsang, Evelin
Horváth, Krisztián
Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography
title Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography
title_full Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography
title_fullStr Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography
title_full_unstemmed Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography
title_short Unbiased Determination of Adsorption Isotherms by Inverse Method in Liquid Chromatography
title_sort unbiased determination of adsorption isotherms by inverse method in liquid chromatography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919363/
https://www.ncbi.nlm.nih.gov/pubmed/36770697
http://dx.doi.org/10.3390/molecules28031031
work_keys_str_mv AT horvathszabolcs unbiaseddeterminationofadsorptionisothermsbyinversemethodinliquidchromatography
AT lukacsdiana unbiaseddeterminationofadsorptionisothermsbyinversemethodinliquidchromatography
AT farsangevelin unbiaseddeterminationofadsorptionisothermsbyinversemethodinliquidchromatography
AT horvathkrisztian unbiaseddeterminationofadsorptionisothermsbyinversemethodinliquidchromatography