Cargando…
Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators
This work analyzes a built-in slider detection method for a charge-induction type electrostatic film actuator with a high surface-resistance slider. In the detection method, one stator electrode is detached from the parallel driving electrodes and is dedicated to sensing. When a slider with induced...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919605/ https://www.ncbi.nlm.nih.gov/pubmed/36772566 http://dx.doi.org/10.3390/s23031529 |
_version_ | 1784886863992979456 |
---|---|
author | Kojima, Motoki Yoshimoto, Shunsuke Yamamoto, Akio |
author_facet | Kojima, Motoki Yoshimoto, Shunsuke Yamamoto, Akio |
author_sort | Kojima, Motoki |
collection | PubMed |
description | This work analyzes a built-in slider detection method for a charge-induction type electrostatic film actuator with a high surface-resistance slider. In the detection method, one stator electrode is detached from the parallel driving electrodes and is dedicated to sensing. When a slider with induced charges moves over the sensing electrode, electrostatic induction occurs in the sensing electrode, which causes an electric current. The current is converted to a voltage through a detection resistance, which will be an output of the sensing circuit. This paper provides a framework to analyze the output signal waveform and shows that the waveform consists of two components. One component is caused by driving voltage and appears regardless of the existence of a slider. The other component corresponds to the movement of a slider, which appears only when a slider is moving over the sensing electrode. Therefore, the slider can be detected by monitoring the latter component. The two components generally overlap, which makes the detection of the latter component difficult in some cases. This paper proposes a method to decouple the two components by switching the detection resistance at an appropriate time. These methods are verified using a prototype actuator that has an electrode pitch of 0.6 mm. The actuator was driven with a set of pulse voltages with an amplitude of 1000 V. The experimental results show similar waveforms to the analytical results, verifying the proposed analytical framework. The performance of the sensing method as a proximity sensor was verified in the experiments, and it was confirmed that the slider can be detected when it approaches the sensing electrode within about 3 mm. |
format | Online Article Text |
id | pubmed-9919605 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99196052023-02-12 Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators Kojima, Motoki Yoshimoto, Shunsuke Yamamoto, Akio Sensors (Basel) Article This work analyzes a built-in slider detection method for a charge-induction type electrostatic film actuator with a high surface-resistance slider. In the detection method, one stator electrode is detached from the parallel driving electrodes and is dedicated to sensing. When a slider with induced charges moves over the sensing electrode, electrostatic induction occurs in the sensing electrode, which causes an electric current. The current is converted to a voltage through a detection resistance, which will be an output of the sensing circuit. This paper provides a framework to analyze the output signal waveform and shows that the waveform consists of two components. One component is caused by driving voltage and appears regardless of the existence of a slider. The other component corresponds to the movement of a slider, which appears only when a slider is moving over the sensing electrode. Therefore, the slider can be detected by monitoring the latter component. The two components generally overlap, which makes the detection of the latter component difficult in some cases. This paper proposes a method to decouple the two components by switching the detection resistance at an appropriate time. These methods are verified using a prototype actuator that has an electrode pitch of 0.6 mm. The actuator was driven with a set of pulse voltages with an amplitude of 1000 V. The experimental results show similar waveforms to the analytical results, verifying the proposed analytical framework. The performance of the sensing method as a proximity sensor was verified in the experiments, and it was confirmed that the slider can be detected when it approaches the sensing electrode within about 3 mm. MDPI 2023-01-30 /pmc/articles/PMC9919605/ /pubmed/36772566 http://dx.doi.org/10.3390/s23031529 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kojima, Motoki Yoshimoto, Shunsuke Yamamoto, Akio Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators |
title | Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators |
title_full | Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators |
title_fullStr | Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators |
title_full_unstemmed | Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators |
title_short | Slider Sheet Detection in Charge-Induction Electrostatic Film Actuators |
title_sort | slider sheet detection in charge-induction electrostatic film actuators |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919605/ https://www.ncbi.nlm.nih.gov/pubmed/36772566 http://dx.doi.org/10.3390/s23031529 |
work_keys_str_mv | AT kojimamotoki slidersheetdetectioninchargeinductionelectrostaticfilmactuators AT yoshimotoshunsuke slidersheetdetectioninchargeinductionelectrostaticfilmactuators AT yamamotoakio slidersheetdetectioninchargeinductionelectrostaticfilmactuators |