Cargando…

Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment

PURPOSE: The scotopic macular integrity assessment (S-MAIA) can perform scotopic assessment to detect localized changes to scotopic rod and cone function. This study is an exploratory investigation of the feasibility of using the S-MAIA in a rod–cone dystrophy population to identify the pattern of l...

Descripción completa

Detalles Bibliográficos
Autores principales: Jolly, Jasleen K., Nanda, Anika, Buckley, Thomas M. W., Pfau, Maximilian, Bridge, Holly, MacLaren, Robert E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919682/
https://www.ncbi.nlm.nih.gov/pubmed/36749581
http://dx.doi.org/10.1167/tvst.12.2.10
_version_ 1784886883582476288
author Jolly, Jasleen K.
Nanda, Anika
Buckley, Thomas M. W.
Pfau, Maximilian
Bridge, Holly
MacLaren, Robert E.
author_facet Jolly, Jasleen K.
Nanda, Anika
Buckley, Thomas M. W.
Pfau, Maximilian
Bridge, Holly
MacLaren, Robert E.
author_sort Jolly, Jasleen K.
collection PubMed
description PURPOSE: The scotopic macular integrity assessment (S-MAIA) can perform scotopic assessment to detect localized changes to scotopic rod and cone function. This study is an exploratory investigation of the feasibility of using the S-MAIA in a rod–cone dystrophy population to identify the pattern of loss in scotopic photoreceptor function. METHODS: Twenty patients diagnosed with a rod–cone dystrophy underwent visual acuity testing, full-field stimulus threshold assessment, and multiple S-MAIA tests after dark adaptation periods of 20 minutes and 45 minutes performed separately. Only right eyes were tested. Three tests were performed following a learning test. A Bland–Altman analysis was used to assess repeatability and agreement between tests after the two time periods. Spatial interpolation maps were created from the group plots to display the pattern of rod and cone loss. RESULTS: Learning effects took place between testing sessions 1 and 2 but not 2 and 3. Limits of agreement were larger in the patient eyes than control eyes, but within previously reported values. Using longer adaptation time of 45 minutes did not offer a significant advantage over 20 minutes. Patterns for the cyan and red sensitivities were different, indicating different patterns of loss for rods and cones. CONCLUSIONS: A dark adaptation time of 20 minutes before testing is sufficient for thresholding. The S-MAIA is suitable for use in patients with a logarithm of the minimum angle of resolution vision of at least 0.7 and provides a viable outcome measure for patients with rod–cone dystrophies and preserved central vision. The spatial information about scotopic function from the S-MAIA provides information about disease processes and progression. TRANSLATIONAL RELEVANCE: There is a need for scotopic measures for use in clinical trials. Scotopic microperimetry works well in patients with early disease, allowing the extension of recruitment criteria for novel therapies of rod–cone dystrophies.
format Online
Article
Text
id pubmed-9919682
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-99196822023-02-12 Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment Jolly, Jasleen K. Nanda, Anika Buckley, Thomas M. W. Pfau, Maximilian Bridge, Holly MacLaren, Robert E. Transl Vis Sci Technol Retina PURPOSE: The scotopic macular integrity assessment (S-MAIA) can perform scotopic assessment to detect localized changes to scotopic rod and cone function. This study is an exploratory investigation of the feasibility of using the S-MAIA in a rod–cone dystrophy population to identify the pattern of loss in scotopic photoreceptor function. METHODS: Twenty patients diagnosed with a rod–cone dystrophy underwent visual acuity testing, full-field stimulus threshold assessment, and multiple S-MAIA tests after dark adaptation periods of 20 minutes and 45 minutes performed separately. Only right eyes were tested. Three tests were performed following a learning test. A Bland–Altman analysis was used to assess repeatability and agreement between tests after the two time periods. Spatial interpolation maps were created from the group plots to display the pattern of rod and cone loss. RESULTS: Learning effects took place between testing sessions 1 and 2 but not 2 and 3. Limits of agreement were larger in the patient eyes than control eyes, but within previously reported values. Using longer adaptation time of 45 minutes did not offer a significant advantage over 20 minutes. Patterns for the cyan and red sensitivities were different, indicating different patterns of loss for rods and cones. CONCLUSIONS: A dark adaptation time of 20 minutes before testing is sufficient for thresholding. The S-MAIA is suitable for use in patients with a logarithm of the minimum angle of resolution vision of at least 0.7 and provides a viable outcome measure for patients with rod–cone dystrophies and preserved central vision. The spatial information about scotopic function from the S-MAIA provides information about disease processes and progression. TRANSLATIONAL RELEVANCE: There is a need for scotopic measures for use in clinical trials. Scotopic microperimetry works well in patients with early disease, allowing the extension of recruitment criteria for novel therapies of rod–cone dystrophies. The Association for Research in Vision and Ophthalmology 2023-02-07 /pmc/articles/PMC9919682/ /pubmed/36749581 http://dx.doi.org/10.1167/tvst.12.2.10 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Retina
Jolly, Jasleen K.
Nanda, Anika
Buckley, Thomas M. W.
Pfau, Maximilian
Bridge, Holly
MacLaren, Robert E.
Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment
title Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment
title_full Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment
title_fullStr Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment
title_full_unstemmed Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment
title_short Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment
title_sort assessment of scotopic function in rod–cone inherited retinal degeneration with the scotopic macular integrity assessment
topic Retina
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919682/
https://www.ncbi.nlm.nih.gov/pubmed/36749581
http://dx.doi.org/10.1167/tvst.12.2.10
work_keys_str_mv AT jollyjasleenk assessmentofscotopicfunctioninrodconeinheritedretinaldegenerationwiththescotopicmacularintegrityassessment
AT nandaanika assessmentofscotopicfunctioninrodconeinheritedretinaldegenerationwiththescotopicmacularintegrityassessment
AT buckleythomasmw assessmentofscotopicfunctioninrodconeinheritedretinaldegenerationwiththescotopicmacularintegrityassessment
AT pfaumaximilian assessmentofscotopicfunctioninrodconeinheritedretinaldegenerationwiththescotopicmacularintegrityassessment
AT bridgeholly assessmentofscotopicfunctioninrodconeinheritedretinaldegenerationwiththescotopicmacularintegrityassessment
AT maclarenroberte assessmentofscotopicfunctioninrodconeinheritedretinaldegenerationwiththescotopicmacularintegrityassessment