Cargando…

Real-Time Risk Assessment Detection for Weak People by Parallel Training Logical Execution of a Supervised Learning System Based on an IoT Wearable MEMS Accelerometer

Activity monitoring has become a necessary demand for weak people to guarantee their safety. The paper proposed a Parallel Training Logical Execution (PTLE) system using machine learning (ML) models on a microelectromechanical system (MEMS) accelerometer to detect coughs, falls, and other normal act...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoang, Minh Long, Nkembi, Armel Asongu, Pham, Phuong Ly
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919808/
https://www.ncbi.nlm.nih.gov/pubmed/36772556
http://dx.doi.org/10.3390/s23031516
Descripción
Sumario:Activity monitoring has become a necessary demand for weak people to guarantee their safety. The paper proposed a Parallel Training Logical Execution (PTLE) system using machine learning (ML) models on a microelectromechanical system (MEMS) accelerometer to detect coughs, falls, and other normal activities. When there are many categories, the ML prediction can be confused between these activities with each other. The PTLE system trains several models in parallel with more specific activity classes in each dataset. The shared tasks between parallel models relieve the complexity for a single one. There are six additional parameters for accelerometer characteristics, which were calculated from three axes accelerations as input features to improve the ML’s consciousness. Once all models were trained, the system was ready to receive the input accelerations and activated the logical flow to manage link operation between these ML models for output predictions. Random Forest (RF) had the highest potential among the ML classification algorithms after the validation. In the experiment, the comparison between the PTLE model and the regular ML model were carried out with real-time data from an M5stickC wearable device on the user’s chest to the trained models on PC. The result showed the advancement of the proposed method in term of precision, recall, F1-score with an overall accuracy of 98% in the real-time test. The accelerations from the wearable device were sent to ML models via Wi-Fi with Message Queue Telemetry Transport (MQTT) broker, and the activity predictions were transferred to the cloud for the family members or doctor care based on Internet of Things (IoT) communication.