Cargando…

Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil

The plate load test (PLT) is the most reliable in situ testing for studying the load–settlement behaviour of footings on unsaturated collapsible soils. In these soils, the suction profile is not constant along the depth, and the scale effect between the prototype and footing leads to different sucti...

Descripción completa

Detalles Bibliográficos
Autores principales: Saab, Alfredo Lopes, Rodrigues, André Luís de Carvalho, Rocha, Breno Padovezi, Rodrigues, Roger Augusto, Giacheti, Heraldo Luiz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919912/
https://www.ncbi.nlm.nih.gov/pubmed/36772469
http://dx.doi.org/10.3390/s23031429
_version_ 1784886940763422720
author Saab, Alfredo Lopes
Rodrigues, André Luís de Carvalho
Rocha, Breno Padovezi
Rodrigues, Roger Augusto
Giacheti, Heraldo Luiz
author_facet Saab, Alfredo Lopes
Rodrigues, André Luís de Carvalho
Rocha, Breno Padovezi
Rodrigues, Roger Augusto
Giacheti, Heraldo Luiz
author_sort Saab, Alfredo Lopes
collection PubMed
description The plate load test (PLT) is the most reliable in situ testing for studying the load–settlement behaviour of footings on unsaturated collapsible soils. In these soils, the suction profile is not constant along the depth, and the scale effect between the prototype and footing leads to different suction averages and, consequently, different data. One method to eliminate the effect of soil suction on the test data is to fully saturate the soil prior to the test, which is also recommended at the design process for footing on collapsible soils. However, the inundation process on PLTs is expensive and time-consuming, which makes this procedure difficult to incorporate into engineering practice. This study presents a device that can be attached to flat dilatometer (DMT) to allow local inundation of the soil as part of the in situ test campaign and obtain the DMT-constrained modulus (M(DMT)) for both natural and inundated conditions. The M(DMT) presented an average reduction of 56% from natural to inundated condition. This parameter can be used in a model to predict load–settlement curves by DMT data considering the suction influence on this behaviour. The curves obtained from the prediction model were compared to curves determined by PLT conducted under the same in situ conditions. Good agreement was found between the curves predicted by DMT and those measured by PLT for both conditions. The proposed procedure, which uses a device attached to the DMT blade, provides an investigation method to obtain the load–settlement curve under different suction conditions, which can help in the selection and performance prediction of shallow foundations, taking into account suction and collapse phenomenon-related problems.
format Online
Article
Text
id pubmed-9919912
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99199122023-02-12 Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil Saab, Alfredo Lopes Rodrigues, André Luís de Carvalho Rocha, Breno Padovezi Rodrigues, Roger Augusto Giacheti, Heraldo Luiz Sensors (Basel) Article The plate load test (PLT) is the most reliable in situ testing for studying the load–settlement behaviour of footings on unsaturated collapsible soils. In these soils, the suction profile is not constant along the depth, and the scale effect between the prototype and footing leads to different suction averages and, consequently, different data. One method to eliminate the effect of soil suction on the test data is to fully saturate the soil prior to the test, which is also recommended at the design process for footing on collapsible soils. However, the inundation process on PLTs is expensive and time-consuming, which makes this procedure difficult to incorporate into engineering practice. This study presents a device that can be attached to flat dilatometer (DMT) to allow local inundation of the soil as part of the in situ test campaign and obtain the DMT-constrained modulus (M(DMT)) for both natural and inundated conditions. The M(DMT) presented an average reduction of 56% from natural to inundated condition. This parameter can be used in a model to predict load–settlement curves by DMT data considering the suction influence on this behaviour. The curves obtained from the prediction model were compared to curves determined by PLT conducted under the same in situ conditions. Good agreement was found between the curves predicted by DMT and those measured by PLT for both conditions. The proposed procedure, which uses a device attached to the DMT blade, provides an investigation method to obtain the load–settlement curve under different suction conditions, which can help in the selection and performance prediction of shallow foundations, taking into account suction and collapse phenomenon-related problems. MDPI 2023-01-27 /pmc/articles/PMC9919912/ /pubmed/36772469 http://dx.doi.org/10.3390/s23031429 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Saab, Alfredo Lopes
Rodrigues, André Luís de Carvalho
Rocha, Breno Padovezi
Rodrigues, Roger Augusto
Giacheti, Heraldo Luiz
Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil
title Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil
title_full Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil
title_fullStr Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil
title_full_unstemmed Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil
title_short Suction Influence on Load–Settlement Curves Predicted by DMT in a Collapsible Sandy Soil
title_sort suction influence on load–settlement curves predicted by dmt in a collapsible sandy soil
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9919912/
https://www.ncbi.nlm.nih.gov/pubmed/36772469
http://dx.doi.org/10.3390/s23031429
work_keys_str_mv AT saabalfredolopes suctioninfluenceonloadsettlementcurvespredictedbydmtinacollapsiblesandysoil
AT rodriguesandreluisdecarvalho suctioninfluenceonloadsettlementcurvespredictedbydmtinacollapsiblesandysoil
AT rochabrenopadovezi suctioninfluenceonloadsettlementcurvespredictedbydmtinacollapsiblesandysoil
AT rodriguesrogeraugusto suctioninfluenceonloadsettlementcurvespredictedbydmtinacollapsiblesandysoil
AT giachetiheraldoluiz suctioninfluenceonloadsettlementcurvespredictedbydmtinacollapsiblesandysoil