Cargando…

Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe

Dental caries is a major oral health issue which compromises oral health, as it is the main cause of oral pain and tooth loss. Early caries detection is essential for effective clinical intervention. However, methods commonly employed for its diagnosis often fail to detect early caries lesions, whic...

Descripción completa

Detalles Bibliográficos
Autores principales: Berezhanska, Mariya, Godinho, Daniela M., Maló, Paulo, Conceição, Raquel C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920056/
https://www.ncbi.nlm.nih.gov/pubmed/36772655
http://dx.doi.org/10.3390/s23031617
_version_ 1784886976494698496
author Berezhanska, Mariya
Godinho, Daniela M.
Maló, Paulo
Conceição, Raquel C.
author_facet Berezhanska, Mariya
Godinho, Daniela M.
Maló, Paulo
Conceição, Raquel C.
author_sort Berezhanska, Mariya
collection PubMed
description Dental caries is a major oral health issue which compromises oral health, as it is the main cause of oral pain and tooth loss. Early caries detection is essential for effective clinical intervention. However, methods commonly employed for its diagnosis often fail to detect early caries lesions, which motivates the research for more effective diagnostic solutions. In this work, the relative permittivity of healthy permanent teeth, in caries-prone areas, was studied between 0.5 and 18 GHz. The reliability of such measurements is an important first step to, ultimately, evaluate the feasibility of a microwave device for caries detection. The open-ended coaxial probe technique was employed. Its performance showed to be compromised by the poor probe-tooth contact. We proposed a method based on applying coupling media to reduce this limitation. A decrease in the measured relative permittivity variability was observed when the space between the probe tip and tooth surface was filled by coupling media instead of air. The influence of the experimental conditions in the measurement result was found to be less than 5%. Measurements conducted in ex vivo teeth showed that the relative permittivity of the dental crown and root ranges between 10.0–11.0 and 8.0–9.5, respectively.
format Online
Article
Text
id pubmed-9920056
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99200562023-02-12 Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe Berezhanska, Mariya Godinho, Daniela M. Maló, Paulo Conceição, Raquel C. Sensors (Basel) Article Dental caries is a major oral health issue which compromises oral health, as it is the main cause of oral pain and tooth loss. Early caries detection is essential for effective clinical intervention. However, methods commonly employed for its diagnosis often fail to detect early caries lesions, which motivates the research for more effective diagnostic solutions. In this work, the relative permittivity of healthy permanent teeth, in caries-prone areas, was studied between 0.5 and 18 GHz. The reliability of such measurements is an important first step to, ultimately, evaluate the feasibility of a microwave device for caries detection. The open-ended coaxial probe technique was employed. Its performance showed to be compromised by the poor probe-tooth contact. We proposed a method based on applying coupling media to reduce this limitation. A decrease in the measured relative permittivity variability was observed when the space between the probe tip and tooth surface was filled by coupling media instead of air. The influence of the experimental conditions in the measurement result was found to be less than 5%. Measurements conducted in ex vivo teeth showed that the relative permittivity of the dental crown and root ranges between 10.0–11.0 and 8.0–9.5, respectively. MDPI 2023-02-02 /pmc/articles/PMC9920056/ /pubmed/36772655 http://dx.doi.org/10.3390/s23031617 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Berezhanska, Mariya
Godinho, Daniela M.
Maló, Paulo
Conceição, Raquel C.
Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe
title Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe
title_full Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe
title_fullStr Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe
title_full_unstemmed Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe
title_short Dielectric Characterization of Healthy Human Teeth from 0.5 to 18 GHz with an Open-Ended Coaxial Probe
title_sort dielectric characterization of healthy human teeth from 0.5 to 18 ghz with an open-ended coaxial probe
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920056/
https://www.ncbi.nlm.nih.gov/pubmed/36772655
http://dx.doi.org/10.3390/s23031617
work_keys_str_mv AT berezhanskamariya dielectriccharacterizationofhealthyhumanteethfrom05to18ghzwithanopenendedcoaxialprobe
AT godinhodanielam dielectriccharacterizationofhealthyhumanteethfrom05to18ghzwithanopenendedcoaxialprobe
AT malopaulo dielectriccharacterizationofhealthyhumanteethfrom05to18ghzwithanopenendedcoaxialprobe
AT conceicaoraquelc dielectriccharacterizationofhealthyhumanteethfrom05to18ghzwithanopenendedcoaxialprobe