Cargando…

Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology

In view of the shortage of structural defect monitoring methods for deep submersibles, numerical simulation and experimental research on underwater SAW propagation based on interdigital transducers are carried out in this paper. PVDF interdigital transducer (PVDF-IDT) has shown considerable potentia...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Zhongjun, Feng, Zhiliang, Li, Hongyu, Meng, Dejian, Zhang, Yi, Li, Dewei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920383/
https://www.ncbi.nlm.nih.gov/pubmed/36772224
http://dx.doi.org/10.3390/s23031184
_version_ 1784887056599613440
author Ding, Zhongjun
Feng, Zhiliang
Li, Hongyu
Meng, Dejian
Zhang, Yi
Li, Dewei
author_facet Ding, Zhongjun
Feng, Zhiliang
Li, Hongyu
Meng, Dejian
Zhang, Yi
Li, Dewei
author_sort Ding, Zhongjun
collection PubMed
description In view of the shortage of structural defect monitoring methods for deep submersibles, numerical simulation and experimental research on underwater SAW propagation based on interdigital transducers are carried out in this paper. PVDF interdigital transducer (PVDF-IDT) has shown considerable potential in the application of structural health monitoring because of its micro size, soft material characteristics, and the characteristics of long-term bonding on the surface of the tested structure. In order to realize the application of IDT on submersible or underwater structures, it is necessary to understand the influence of underwater environment on IDTs with different structures. The underwater attenuation of IDT with 2–5 mm wavelength and the underwater attenuation of Lamb (A0 mode) wave on a 4 mm thick titanium alloy plate is obtained through COMSOL software simulation. The experimental verification shows that the simulation results match with the actual situation, which proves that COMSOL software can accurately calculate the acoustic attenuation of surface waves at the solid–liquid interface. At the same time, the underwater attenuation of IDT with different structures is very different, providing important design parameters for the underwater interdigital transducer. In this paper, it is found that the Lamb wave has significant advantages over the Rayleigh wave in the health monitoring of underwater thin plate structures.
format Online
Article
Text
id pubmed-9920383
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99203832023-02-12 Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology Ding, Zhongjun Feng, Zhiliang Li, Hongyu Meng, Dejian Zhang, Yi Li, Dewei Sensors (Basel) Article In view of the shortage of structural defect monitoring methods for deep submersibles, numerical simulation and experimental research on underwater SAW propagation based on interdigital transducers are carried out in this paper. PVDF interdigital transducer (PVDF-IDT) has shown considerable potential in the application of structural health monitoring because of its micro size, soft material characteristics, and the characteristics of long-term bonding on the surface of the tested structure. In order to realize the application of IDT on submersible or underwater structures, it is necessary to understand the influence of underwater environment on IDTs with different structures. The underwater attenuation of IDT with 2–5 mm wavelength and the underwater attenuation of Lamb (A0 mode) wave on a 4 mm thick titanium alloy plate is obtained through COMSOL software simulation. The experimental verification shows that the simulation results match with the actual situation, which proves that COMSOL software can accurately calculate the acoustic attenuation of surface waves at the solid–liquid interface. At the same time, the underwater attenuation of IDT with different structures is very different, providing important design parameters for the underwater interdigital transducer. In this paper, it is found that the Lamb wave has significant advantages over the Rayleigh wave in the health monitoring of underwater thin plate structures. MDPI 2023-01-20 /pmc/articles/PMC9920383/ /pubmed/36772224 http://dx.doi.org/10.3390/s23031184 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ding, Zhongjun
Feng, Zhiliang
Li, Hongyu
Meng, Dejian
Zhang, Yi
Li, Dewei
Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology
title Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology
title_full Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology
title_fullStr Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology
title_full_unstemmed Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology
title_short Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology
title_sort experimental study of deep submersible structure defect monitoring based on flexible interdigital transducer surface acoustic wave technology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920383/
https://www.ncbi.nlm.nih.gov/pubmed/36772224
http://dx.doi.org/10.3390/s23031184
work_keys_str_mv AT dingzhongjun experimentalstudyofdeepsubmersiblestructuredefectmonitoringbasedonflexibleinterdigitaltransducersurfaceacousticwavetechnology
AT fengzhiliang experimentalstudyofdeepsubmersiblestructuredefectmonitoringbasedonflexibleinterdigitaltransducersurfaceacousticwavetechnology
AT lihongyu experimentalstudyofdeepsubmersiblestructuredefectmonitoringbasedonflexibleinterdigitaltransducersurfaceacousticwavetechnology
AT mengdejian experimentalstudyofdeepsubmersiblestructuredefectmonitoringbasedonflexibleinterdigitaltransducersurfaceacousticwavetechnology
AT zhangyi experimentalstudyofdeepsubmersiblestructuredefectmonitoringbasedonflexibleinterdigitaltransducersurfaceacousticwavetechnology
AT lidewei experimentalstudyofdeepsubmersiblestructuredefectmonitoringbasedonflexibleinterdigitaltransducersurfaceacousticwavetechnology