Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)

Research has shown that pulse transit time (PTT), which is the time delay between the electrocardiogram (ECG) signal and the signal from a photoplethysmogram (PPG) sensor, can be used to estimate systolic blood pressure (SBP) and diastolic blood pressure (DBP) without the need for a cuff. However, t...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jingyu, Kang, Younghwan, Park, Jaesoon, Joung, Yeunho, Koo, Chiwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920508/
https://www.ncbi.nlm.nih.gov/pubmed/36772724
http://dx.doi.org/10.3390/s23031684
_version_ 1784887087402582016
author Choi, Jingyu
Kang, Younghwan
Park, Jaesoon
Joung, Yeunho
Koo, Chiwan
author_facet Choi, Jingyu
Kang, Younghwan
Park, Jaesoon
Joung, Yeunho
Koo, Chiwan
author_sort Choi, Jingyu
collection PubMed
description Research has shown that pulse transit time (PTT), which is the time delay between the electrocardiogram (ECG) signal and the signal from a photoplethysmogram (PPG) sensor, can be used to estimate systolic blood pressure (SBP) and diastolic blood pressure (DBP) without the need for a cuff. However, the LED of the PPG sensor requires the precise adjustment of both light intensity and light absorption rates according to the contact status of the light-receiving element. This results in the need for regular calibration. In this study, we propose a cuffless blood pressure monitor that measures real-time blood pressure using a microphone instead of a PPG sensor. The blood pulse wave is measured in the radial artery of the wrist using a microphone that can directly measure the sound generated by a body rather than sending energy inside the body and receiving a returning signal. Our blood pressure monitor uses the PTT between the R-peak of the ECG signal and two feature points of the blood pulse wave in the radial artery of the wrist. ECG electrodes and circuits were fabricated, and a commercial microelectromechanical system (MEMS) microphone was used as the microphone to measure blood pulses. The peak points of the blood pulse from the microphone were clear, so the estimated SBP and DBP could be obtained from each ECG pulse in real time, and the resulting estimations were similar to those made by a commercial cuff blood pressure monitor. Since neither the ECG electrodes nor the microphone requires calibration over time, the real-time cuffless blood pressure monitor does not require calibration. Using the developed device, blood pressure was measured three times daily for five days, and the mean absolute error (MAE) and standard deviation (SD) of the SBP and DBP were found to be 2.72 ± 3.42 mmHg and 2.29 ± 3.53 mmHg, respectively. As a preliminary study for proof-of-concept, these results were obtained from one subject. The next step will be a pilot study on a large number of subjects.
format Online
Article
Text
id pubmed-9920508
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99205082023-02-12 Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT) Choi, Jingyu Kang, Younghwan Park, Jaesoon Joung, Yeunho Koo, Chiwan Sensors (Basel) Article Research has shown that pulse transit time (PTT), which is the time delay between the electrocardiogram (ECG) signal and the signal from a photoplethysmogram (PPG) sensor, can be used to estimate systolic blood pressure (SBP) and diastolic blood pressure (DBP) without the need for a cuff. However, the LED of the PPG sensor requires the precise adjustment of both light intensity and light absorption rates according to the contact status of the light-receiving element. This results in the need for regular calibration. In this study, we propose a cuffless blood pressure monitor that measures real-time blood pressure using a microphone instead of a PPG sensor. The blood pulse wave is measured in the radial artery of the wrist using a microphone that can directly measure the sound generated by a body rather than sending energy inside the body and receiving a returning signal. Our blood pressure monitor uses the PTT between the R-peak of the ECG signal and two feature points of the blood pulse wave in the radial artery of the wrist. ECG electrodes and circuits were fabricated, and a commercial microelectromechanical system (MEMS) microphone was used as the microphone to measure blood pulses. The peak points of the blood pulse from the microphone were clear, so the estimated SBP and DBP could be obtained from each ECG pulse in real time, and the resulting estimations were similar to those made by a commercial cuff blood pressure monitor. Since neither the ECG electrodes nor the microphone requires calibration over time, the real-time cuffless blood pressure monitor does not require calibration. Using the developed device, blood pressure was measured three times daily for five days, and the mean absolute error (MAE) and standard deviation (SD) of the SBP and DBP were found to be 2.72 ± 3.42 mmHg and 2.29 ± 3.53 mmHg, respectively. As a preliminary study for proof-of-concept, these results were obtained from one subject. The next step will be a pilot study on a large number of subjects. MDPI 2023-02-03 /pmc/articles/PMC9920508/ /pubmed/36772724 http://dx.doi.org/10.3390/s23031684 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Choi, Jingyu
Kang, Younghwan
Park, Jaesoon
Joung, Yeunho
Koo, Chiwan
Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
title Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
title_full Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
title_fullStr Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
title_full_unstemmed Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
title_short Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
title_sort development of real-time cuffless blood pressure measurement systems with ecg electrodes and a microphone using pulse transit time (ptt)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920508/
https://www.ncbi.nlm.nih.gov/pubmed/36772724
http://dx.doi.org/10.3390/s23031684
work_keys_str_mv AT choijingyu developmentofrealtimecufflessbloodpressuremeasurementsystemswithecgelectrodesandamicrophoneusingpulsetransittimeptt
AT kangyounghwan developmentofrealtimecufflessbloodpressuremeasurementsystemswithecgelectrodesandamicrophoneusingpulsetransittimeptt
AT parkjaesoon developmentofrealtimecufflessbloodpressuremeasurementsystemswithecgelectrodesandamicrophoneusingpulsetransittimeptt
AT joungyeunho developmentofrealtimecufflessbloodpressuremeasurementsystemswithecgelectrodesandamicrophoneusingpulsetransittimeptt
AT koochiwan developmentofrealtimecufflessbloodpressuremeasurementsystemswithecgelectrodesandamicrophoneusingpulsetransittimeptt