Cargando…

Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis

Improvements in the diagnosis and treatment of cardiovascular diseases facilitate a better understanding of the ongoing process. The study of biomedical fluid dynamics using non-intrusive visualizing methods on a micro-scale has become possible using a proper 3D printing process. The computed tomogr...

Descripción completa

Detalles Bibliográficos
Autores principales: Antonowicz, Arkadiusz, Wojtas, Krzysztof, Makowski, Łukasz, Orciuch, Wojciech, Kozłowski, Michał
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920660/
https://www.ncbi.nlm.nih.gov/pubmed/36770062
http://dx.doi.org/10.3390/ma16031055
_version_ 1784887124573552640
author Antonowicz, Arkadiusz
Wojtas, Krzysztof
Makowski, Łukasz
Orciuch, Wojciech
Kozłowski, Michał
author_facet Antonowicz, Arkadiusz
Wojtas, Krzysztof
Makowski, Łukasz
Orciuch, Wojciech
Kozłowski, Michał
author_sort Antonowicz, Arkadiusz
collection PubMed
description Improvements in the diagnosis and treatment of cardiovascular diseases facilitate a better understanding of the ongoing process. The study of biomedical fluid dynamics using non-intrusive visualizing methods on a micro-scale has become possible using a proper 3D printing process. The computed tomography scan of a patient with atherosclerosis was processed, and a 3D-printed artery with an inlet diameter of 4.2 mm was developed and measured using three different constant flow rates. To mimic blood, a solution of glycerin and water was used. The procedure to obtain a proper 3D-printed model using low-force stereolithography technology with high-quality optical access usable for PIV was described and discussed. The paper presents the results of PIV as multi-stitched, color-coded vector maps from the axis cross section along the whole 3D-printed model. The obtained data allowed a resolution of 100 × 100 µm per single vector to be achieved. Furthermore, the results of the stitched 16 base images of the artery and the 3D-printed model prepared were included. The results of this study show that 3D prints allow for the creation of the desired geometry and can be used to investigate severe pathologies of the human circulatory system. The strengths and weaknesses of this methodology were discussed and compared to other techniques used to obtain transparent objects.
format Online
Article
Text
id pubmed-9920660
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99206602023-02-12 Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis Antonowicz, Arkadiusz Wojtas, Krzysztof Makowski, Łukasz Orciuch, Wojciech Kozłowski, Michał Materials (Basel) Article Improvements in the diagnosis and treatment of cardiovascular diseases facilitate a better understanding of the ongoing process. The study of biomedical fluid dynamics using non-intrusive visualizing methods on a micro-scale has become possible using a proper 3D printing process. The computed tomography scan of a patient with atherosclerosis was processed, and a 3D-printed artery with an inlet diameter of 4.2 mm was developed and measured using three different constant flow rates. To mimic blood, a solution of glycerin and water was used. The procedure to obtain a proper 3D-printed model using low-force stereolithography technology with high-quality optical access usable for PIV was described and discussed. The paper presents the results of PIV as multi-stitched, color-coded vector maps from the axis cross section along the whole 3D-printed model. The obtained data allowed a resolution of 100 × 100 µm per single vector to be achieved. Furthermore, the results of the stitched 16 base images of the artery and the 3D-printed model prepared were included. The results of this study show that 3D prints allow for the creation of the desired geometry and can be used to investigate severe pathologies of the human circulatory system. The strengths and weaknesses of this methodology were discussed and compared to other techniques used to obtain transparent objects. MDPI 2023-01-25 /pmc/articles/PMC9920660/ /pubmed/36770062 http://dx.doi.org/10.3390/ma16031055 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Antonowicz, Arkadiusz
Wojtas, Krzysztof
Makowski, Łukasz
Orciuch, Wojciech
Kozłowski, Michał
Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis
title Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis
title_full Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis
title_fullStr Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis
title_full_unstemmed Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis
title_short Particle Image Velocimetry of 3D-Printed Anatomical Blood Vascular Models Affected by Atherosclerosis
title_sort particle image velocimetry of 3d-printed anatomical blood vascular models affected by atherosclerosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9920660/
https://www.ncbi.nlm.nih.gov/pubmed/36770062
http://dx.doi.org/10.3390/ma16031055
work_keys_str_mv AT antonowiczarkadiusz particleimagevelocimetryof3dprintedanatomicalbloodvascularmodelsaffectedbyatherosclerosis
AT wojtaskrzysztof particleimagevelocimetryof3dprintedanatomicalbloodvascularmodelsaffectedbyatherosclerosis
AT makowskiłukasz particleimagevelocimetryof3dprintedanatomicalbloodvascularmodelsaffectedbyatherosclerosis
AT orciuchwojciech particleimagevelocimetryof3dprintedanatomicalbloodvascularmodelsaffectedbyatherosclerosis
AT kozłowskimichał particleimagevelocimetryof3dprintedanatomicalbloodvascularmodelsaffectedbyatherosclerosis