Cargando…

Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method

The aim of this study was to investigate leachable components (monomers) in high and low viscosity dental bulk-fill resin composites and conventional resin composite materials after polymerization. Six bulk-fill and six conventional dental resin composite materials were used in this study. The sampl...

Descripción completa

Detalles Bibliográficos
Autores principales: Barišić, Matea Lapaš, Sarajlija, Hrvoje, Klarić, Eva, Knežević, Alena, Sabol, Ivan, Pandurić, Vlatko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921113/
https://www.ncbi.nlm.nih.gov/pubmed/36771928
http://dx.doi.org/10.3390/polym15030627
_version_ 1784887234169667584
author Barišić, Matea Lapaš
Sarajlija, Hrvoje
Klarić, Eva
Knežević, Alena
Sabol, Ivan
Pandurić, Vlatko
author_facet Barišić, Matea Lapaš
Sarajlija, Hrvoje
Klarić, Eva
Knežević, Alena
Sabol, Ivan
Pandurić, Vlatko
author_sort Barišić, Matea Lapaš
collection PubMed
description The aim of this study was to investigate leachable components (monomers) in high and low viscosity dental bulk-fill resin composites and conventional resin composite materials after polymerization. Six bulk-fill and six conventional dental resin composite materials were used in this study. The samples of each material (three sets of triplicates) were cured for 20 s with irradiance of 1200 mW/cm(2) with a LED curing unit and immersed in a 75% ethanol solution at 37 °C. The eluates from each triplicate set were analyzed after 24 h, 7 days or 28 days using liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS). Detectable amounts of 2-Hydroxyethyl methacrylate (HEMA) were found in both Gradia materials and the amount observed across different time points was statistically different (p ˂ 0.05), with the amount in solution increasing for Gradia and decreasing for Gradia Direct flo. Bisphenol A diglycidildimethacrylate (BIS GMA) was found in Filtek and Tetric materials. Triethylene glycol dimethacrylate (TEGDMA) was detected in all materials. On the other hand, there were no statistically significant differences in the amounts of TEGDMA detected across different time points in either of the tested materials. Monomers HEMA, TEGDMA, 4-dimethylaminobenzoic acid ethyl ester (DMA BEE) and BIS GMA in bulk-fill and conventional composites (high and low viscosity) can be eluted after polymerization. The good selection of composite material and proper handling, the following of the manufacturer’s instructions for polymerization and the use of finishing and polishing procedures may reduce the elution of the unpolymerized monomers> responsible for the possible allergic and genotoxic potential of dental resin composites.
format Online
Article
Text
id pubmed-9921113
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99211132023-02-12 Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method Barišić, Matea Lapaš Sarajlija, Hrvoje Klarić, Eva Knežević, Alena Sabol, Ivan Pandurić, Vlatko Polymers (Basel) Article The aim of this study was to investigate leachable components (monomers) in high and low viscosity dental bulk-fill resin composites and conventional resin composite materials after polymerization. Six bulk-fill and six conventional dental resin composite materials were used in this study. The samples of each material (three sets of triplicates) were cured for 20 s with irradiance of 1200 mW/cm(2) with a LED curing unit and immersed in a 75% ethanol solution at 37 °C. The eluates from each triplicate set were analyzed after 24 h, 7 days or 28 days using liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS). Detectable amounts of 2-Hydroxyethyl methacrylate (HEMA) were found in both Gradia materials and the amount observed across different time points was statistically different (p ˂ 0.05), with the amount in solution increasing for Gradia and decreasing for Gradia Direct flo. Bisphenol A diglycidildimethacrylate (BIS GMA) was found in Filtek and Tetric materials. Triethylene glycol dimethacrylate (TEGDMA) was detected in all materials. On the other hand, there were no statistically significant differences in the amounts of TEGDMA detected across different time points in either of the tested materials. Monomers HEMA, TEGDMA, 4-dimethylaminobenzoic acid ethyl ester (DMA BEE) and BIS GMA in bulk-fill and conventional composites (high and low viscosity) can be eluted after polymerization. The good selection of composite material and proper handling, the following of the manufacturer’s instructions for polymerization and the use of finishing and polishing procedures may reduce the elution of the unpolymerized monomers> responsible for the possible allergic and genotoxic potential of dental resin composites. MDPI 2023-01-25 /pmc/articles/PMC9921113/ /pubmed/36771928 http://dx.doi.org/10.3390/polym15030627 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Barišić, Matea Lapaš
Sarajlija, Hrvoje
Klarić, Eva
Knežević, Alena
Sabol, Ivan
Pandurić, Vlatko
Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method
title Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method
title_full Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method
title_fullStr Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method
title_full_unstemmed Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method
title_short Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method
title_sort detection of leachable components from conventional and dental bulk-fill resin composites (high and low viscosity) using liquid chromatography-tandem mass spectrometry (lc-ms/ms) method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921113/
https://www.ncbi.nlm.nih.gov/pubmed/36771928
http://dx.doi.org/10.3390/polym15030627
work_keys_str_mv AT barisicmatealapas detectionofleachablecomponentsfromconventionalanddentalbulkfillresincompositeshighandlowviscosityusingliquidchromatographytandemmassspectrometrylcmsmsmethod
AT sarajlijahrvoje detectionofleachablecomponentsfromconventionalanddentalbulkfillresincompositeshighandlowviscosityusingliquidchromatographytandemmassspectrometrylcmsmsmethod
AT klariceva detectionofleachablecomponentsfromconventionalanddentalbulkfillresincompositeshighandlowviscosityusingliquidchromatographytandemmassspectrometrylcmsmsmethod
AT knezevicalena detectionofleachablecomponentsfromconventionalanddentalbulkfillresincompositeshighandlowviscosityusingliquidchromatographytandemmassspectrometrylcmsmsmethod
AT sabolivan detectionofleachablecomponentsfromconventionalanddentalbulkfillresincompositeshighandlowviscosityusingliquidchromatographytandemmassspectrometrylcmsmsmethod
AT panduricvlatko detectionofleachablecomponentsfromconventionalanddentalbulkfillresincompositeshighandlowviscosityusingliquidchromatographytandemmassspectrometrylcmsmsmethod