Cargando…
Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System
Conventional heating ventilation and air-conditioning (HVAC) controllers have been designed to mainly control the temperature of a confined compartment, such as a room or a cabin of a vehicle. Other important parameters related to the thermal comfort and indoor air quality (IAQ) of the confined comp...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921170/ https://www.ncbi.nlm.nih.gov/pubmed/36772432 http://dx.doi.org/10.3390/s23031395 |
_version_ | 1784887247887138816 |
---|---|
author | Rajeswari Subramaniam, Konguvel Cheng, Chi-Tsun Pang, Toh Yen |
author_facet | Rajeswari Subramaniam, Konguvel Cheng, Chi-Tsun Pang, Toh Yen |
author_sort | Rajeswari Subramaniam, Konguvel |
collection | PubMed |
description | Conventional heating ventilation and air-conditioning (HVAC) controllers have been designed to mainly control the temperature of a confined compartment, such as a room or a cabin of a vehicle. Other important parameters related to the thermal comfort and indoor air quality (IAQ) of the confined compartment have often been ignored. In this project, IAQ in the vehicle cabin was represented by its carbon dioxide (CO(2)) concentration, and the occupants’ thermal comfort levels were estimated with the predicted mean vote (PMV) index. A new fuzzy logic controller (FLC) was designed and developed using the MATLAB fuzzy logic toolbox and Simulink to provide a nonlinear mapping between the measured values, i.e., PMV, temperature, CO(2), and control parameters (recirculation flaps, blower’s speed, and refrigerant mass flow rate) of a vehicle HVAC system. The new FLC aimed to regulate both in-cabin PMV and CO(2) values without significantly increasing overall energy consumption. To evaluate the effectiveness of the proposed FLC, a cabin simulator was used to mimic the effects of different HVAC variables and indoor/outdoor environmental settings, which represented the in-cabin PMV and IAQ readings. Results demonstrated that the new FLC was effective in regulating the in-cabin PMV level and CO(2) concentration, at desirable levels, by adaptively controlling the opening and closing of the recirculation flap based on in-cabin temperature and CO(2) readings, while maintaining an average-to-good energy consumption level. The proposed FLC could be applied to a large variety of HVAC systems by utilizing low-cost sensors, without the need to significantly modify the internal design of the HVAC system. |
format | Online Article Text |
id | pubmed-9921170 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99211702023-02-12 Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System Rajeswari Subramaniam, Konguvel Cheng, Chi-Tsun Pang, Toh Yen Sensors (Basel) Article Conventional heating ventilation and air-conditioning (HVAC) controllers have been designed to mainly control the temperature of a confined compartment, such as a room or a cabin of a vehicle. Other important parameters related to the thermal comfort and indoor air quality (IAQ) of the confined compartment have often been ignored. In this project, IAQ in the vehicle cabin was represented by its carbon dioxide (CO(2)) concentration, and the occupants’ thermal comfort levels were estimated with the predicted mean vote (PMV) index. A new fuzzy logic controller (FLC) was designed and developed using the MATLAB fuzzy logic toolbox and Simulink to provide a nonlinear mapping between the measured values, i.e., PMV, temperature, CO(2), and control parameters (recirculation flaps, blower’s speed, and refrigerant mass flow rate) of a vehicle HVAC system. The new FLC aimed to regulate both in-cabin PMV and CO(2) values without significantly increasing overall energy consumption. To evaluate the effectiveness of the proposed FLC, a cabin simulator was used to mimic the effects of different HVAC variables and indoor/outdoor environmental settings, which represented the in-cabin PMV and IAQ readings. Results demonstrated that the new FLC was effective in regulating the in-cabin PMV level and CO(2) concentration, at desirable levels, by adaptively controlling the opening and closing of the recirculation flap based on in-cabin temperature and CO(2) readings, while maintaining an average-to-good energy consumption level. The proposed FLC could be applied to a large variety of HVAC systems by utilizing low-cost sensors, without the need to significantly modify the internal design of the HVAC system. MDPI 2023-01-26 /pmc/articles/PMC9921170/ /pubmed/36772432 http://dx.doi.org/10.3390/s23031395 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rajeswari Subramaniam, Konguvel Cheng, Chi-Tsun Pang, Toh Yen Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System |
title | Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System |
title_full | Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System |
title_fullStr | Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System |
title_full_unstemmed | Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System |
title_short | Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System |
title_sort | fuzzy logic controlled simulation in regulating thermal comfort and indoor air quality using a vehicle heating, ventilation, and air-conditioning system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921170/ https://www.ncbi.nlm.nih.gov/pubmed/36772432 http://dx.doi.org/10.3390/s23031395 |
work_keys_str_mv | AT rajeswarisubramaniamkonguvel fuzzylogiccontrolledsimulationinregulatingthermalcomfortandindoorairqualityusingavehicleheatingventilationandairconditioningsystem AT chengchitsun fuzzylogiccontrolledsimulationinregulatingthermalcomfortandindoorairqualityusingavehicleheatingventilationandairconditioningsystem AT pangtohyen fuzzylogiccontrolledsimulationinregulatingthermalcomfortandindoorairqualityusingavehicleheatingventilationandairconditioningsystem |