Cargando…

SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †

The on-board communication standard adopted in current generation space missions of the European Space Agency, and many other agencies as well, is SpaceWire (SpW). In a SpW network, data are exchanged as well-formed packets, whose structure offers low packet overhead and allows developers to tailor...

Descripción completa

Detalles Bibliográficos
Autores principales: Ciardi, Roberto, Vagaggini, Simone, Marino, Antonino, Nannipieri, Pietro, Fanucci, Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921598/
https://www.ncbi.nlm.nih.gov/pubmed/36772620
http://dx.doi.org/10.3390/s23031580
_version_ 1784887350229204992
author Ciardi, Roberto
Vagaggini, Simone
Marino, Antonino
Nannipieri, Pietro
Fanucci, Luca
author_facet Ciardi, Roberto
Vagaggini, Simone
Marino, Antonino
Nannipieri, Pietro
Fanucci, Luca
author_sort Ciardi, Roberto
collection PubMed
description The on-board communication standard adopted in current generation space missions of the European Space Agency, and many other agencies as well, is SpaceWire (SpW). In a SpW network, data are exchanged as well-formed packets, whose structure offers low packet overhead and allows developers to tailor their implementation for SpW applications. The development of SpW-compliant devices requires a specific set of test instruments, namely Electrical Ground Support Equipment (EGSE), to verify the correct functionality of SpW units under test. An example of a SpW EGSE is the SpaceART EGSE Emulator, an EGSE for generation and processing of SpW packets for a time-constrained use-case scenario. This EGSE has been developed to address a mission-related SpW communication between a device and an Instrument Control Unit (ICU). It has allowed the generation and processing of specific SpW packets, which cannot be provided by the mostly used general-purpose SpW EGSEs. In this scope, the SpaceART SpW Sniffer, a SpW link analyser for unobtrusive monitoring of SpW link, has been employed to run a comprehensive set of tests and provide further information on the considered scenario. The SpaceART EGSE Emulator-ICU communication has been thoroughly tested through the SpaceART SpW Sniffer, unobtrusively analysing the exchanged data and allowing to assess the compliance with the defined time constraints from an external point of view. The use of the Sniffer has been crucial for testing the on-board communication, providing important support for the success of the mission employing the tested ICU.
format Online
Article
Text
id pubmed-9921598
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99215982023-02-12 SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario † Ciardi, Roberto Vagaggini, Simone Marino, Antonino Nannipieri, Pietro Fanucci, Luca Sensors (Basel) Article The on-board communication standard adopted in current generation space missions of the European Space Agency, and many other agencies as well, is SpaceWire (SpW). In a SpW network, data are exchanged as well-formed packets, whose structure offers low packet overhead and allows developers to tailor their implementation for SpW applications. The development of SpW-compliant devices requires a specific set of test instruments, namely Electrical Ground Support Equipment (EGSE), to verify the correct functionality of SpW units under test. An example of a SpW EGSE is the SpaceART EGSE Emulator, an EGSE for generation and processing of SpW packets for a time-constrained use-case scenario. This EGSE has been developed to address a mission-related SpW communication between a device and an Instrument Control Unit (ICU). It has allowed the generation and processing of specific SpW packets, which cannot be provided by the mostly used general-purpose SpW EGSEs. In this scope, the SpaceART SpW Sniffer, a SpW link analyser for unobtrusive monitoring of SpW link, has been employed to run a comprehensive set of tests and provide further information on the considered scenario. The SpaceART EGSE Emulator-ICU communication has been thoroughly tested through the SpaceART SpW Sniffer, unobtrusively analysing the exchanged data and allowing to assess the compliance with the defined time constraints from an external point of view. The use of the Sniffer has been crucial for testing the on-board communication, providing important support for the success of the mission employing the tested ICU. MDPI 2023-02-01 /pmc/articles/PMC9921598/ /pubmed/36772620 http://dx.doi.org/10.3390/s23031580 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ciardi, Roberto
Vagaggini, Simone
Marino, Antonino
Nannipieri, Pietro
Fanucci, Luca
SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †
title SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †
title_full SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †
title_fullStr SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †
title_full_unstemmed SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †
title_short SpaceART SpaceWire Sniffer for Link Monitoring: A Complete Communication Analysis in a Time-Constrained Test Scenario †
title_sort spaceart spacewire sniffer for link monitoring: a complete communication analysis in a time-constrained test scenario †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921598/
https://www.ncbi.nlm.nih.gov/pubmed/36772620
http://dx.doi.org/10.3390/s23031580
work_keys_str_mv AT ciardiroberto spaceartspacewiresnifferforlinkmonitoringacompletecommunicationanalysisinatimeconstrainedtestscenario
AT vagagginisimone spaceartspacewiresnifferforlinkmonitoringacompletecommunicationanalysisinatimeconstrainedtestscenario
AT marinoantonino spaceartspacewiresnifferforlinkmonitoringacompletecommunicationanalysisinatimeconstrainedtestscenario
AT nannipieripietro spaceartspacewiresnifferforlinkmonitoringacompletecommunicationanalysisinatimeconstrainedtestscenario
AT fanucciluca spaceartspacewiresnifferforlinkmonitoringacompletecommunicationanalysisinatimeconstrainedtestscenario