Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures

BACKGROUND: The purpose of this study was to investigate the mechanical stability of the posterior acetabular column plate and different posterior acetabular wall prostheses used in treating posterior acetabular fractures with or without comminution. METHODS: The unilateral normal ilium was reconstr...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Guixiong, Wan, Yizhou, Chen, Kaifang, Yin, Zhenchun, Song, Qinghua, Xu, Yi, Guo, Xiaodong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9922446/
https://www.ncbi.nlm.nih.gov/pubmed/36774499
http://dx.doi.org/10.1186/s13018-023-03535-9
_version_ 1784887537470275584
author Huang, Guixiong
Wan, Yizhou
Chen, Kaifang
Yin, Zhenchun
Song, Qinghua
Xu, Yi
Guo, Xiaodong
author_facet Huang, Guixiong
Wan, Yizhou
Chen, Kaifang
Yin, Zhenchun
Song, Qinghua
Xu, Yi
Guo, Xiaodong
author_sort Huang, Guixiong
collection PubMed
description BACKGROUND: The purpose of this study was to investigate the mechanical stability of the posterior acetabular column plate and different posterior acetabular wall prostheses used in treating posterior acetabular fractures with or without comminution. METHODS: The unilateral normal ilium was reconstructed, and a model of posterior acetabular wall fracture was established on this basis. The fracture fragment accounted for approximately 40% of the posterior acetabular wall. The posterior acetabular column plate and different posterior acetabular wall prostheses were also designed. Using static and dynamic analysis methods, we observed and compared the changes in the stress and displacement values of different models at different hip joint flexion angles under external forces. RESULTS: At different hip flexion angles, the stress of each model mainly fluctuated between 37.98 MPa and 1129.00 MPa, and the displacement mainly fluctuated between 0.076 and 6.955 mm. In the dynamic analysis, the nodal stress‒time curves of the models were nonlinear, and the stress changed sharply during the action time. Most of the nodal displacement‒time curves of the models were relatively smooth, with no dramatic changes in displacement during the action time; additionally, most of the curves were relatively consistent in shape. CONCLUSIONS: For simple posterior acetabular wall fractures, we recommend using a posterior acetabular column plate. In the case of comminuted posterior acetabular fractures, we recommend the use of a nonflanked posterior acetabular prosthesis or a biflanked posterior acetabular prosthesis. Regarding the method of acetabular prosthesis design, we propose the concept of “Break up to Make up” as a guide.
format Online
Article
Text
id pubmed-9922446
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-99224462023-02-13 Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures Huang, Guixiong Wan, Yizhou Chen, Kaifang Yin, Zhenchun Song, Qinghua Xu, Yi Guo, Xiaodong J Orthop Surg Res Research Article BACKGROUND: The purpose of this study was to investigate the mechanical stability of the posterior acetabular column plate and different posterior acetabular wall prostheses used in treating posterior acetabular fractures with or without comminution. METHODS: The unilateral normal ilium was reconstructed, and a model of posterior acetabular wall fracture was established on this basis. The fracture fragment accounted for approximately 40% of the posterior acetabular wall. The posterior acetabular column plate and different posterior acetabular wall prostheses were also designed. Using static and dynamic analysis methods, we observed and compared the changes in the stress and displacement values of different models at different hip joint flexion angles under external forces. RESULTS: At different hip flexion angles, the stress of each model mainly fluctuated between 37.98 MPa and 1129.00 MPa, and the displacement mainly fluctuated between 0.076 and 6.955 mm. In the dynamic analysis, the nodal stress‒time curves of the models were nonlinear, and the stress changed sharply during the action time. Most of the nodal displacement‒time curves of the models were relatively smooth, with no dramatic changes in displacement during the action time; additionally, most of the curves were relatively consistent in shape. CONCLUSIONS: For simple posterior acetabular wall fractures, we recommend using a posterior acetabular column plate. In the case of comminuted posterior acetabular fractures, we recommend the use of a nonflanked posterior acetabular prosthesis or a biflanked posterior acetabular prosthesis. Regarding the method of acetabular prosthesis design, we propose the concept of “Break up to Make up” as a guide. BioMed Central 2023-02-11 /pmc/articles/PMC9922446/ /pubmed/36774499 http://dx.doi.org/10.1186/s13018-023-03535-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Huang, Guixiong
Wan, Yizhou
Chen, Kaifang
Yin, Zhenchun
Song, Qinghua
Xu, Yi
Guo, Xiaodong
Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
title Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
title_full Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
title_fullStr Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
title_full_unstemmed Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
title_short Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
title_sort finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9922446/
https://www.ncbi.nlm.nih.gov/pubmed/36774499
http://dx.doi.org/10.1186/s13018-023-03535-9
work_keys_str_mv AT huangguixiong finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures
AT wanyizhou finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures
AT chenkaifang finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures
AT yinzhenchun finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures
AT songqinghua finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures
AT xuyi finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures
AT guoxiaodong finiteelementanalysisofposterioracetabularcolumnplateandposterioracetabularwallprosthesesintreatingposterioracetabularfractures