Cargando…
Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study
BACKGROUND: To compare the 6-month changes in aberration and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for high astigmatism. METHODS: In this retrospective case control study, 47 eyes with high astigmatism (≥ 2.5 D, HA group) and 47 eyes with low astigmati...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9923895/ https://www.ncbi.nlm.nih.gov/pubmed/36782180 http://dx.doi.org/10.1186/s12886-023-02809-4 |
_version_ | 1784887798735568896 |
---|---|
author | Li, Na Chen, Tong Tian, Ge Lin, Yue Meng, Yuan Gao, Hua Liu, Mingna |
author_facet | Li, Na Chen, Tong Tian, Ge Lin, Yue Meng, Yuan Gao, Hua Liu, Mingna |
author_sort | Li, Na |
collection | PubMed |
description | BACKGROUND: To compare the 6-month changes in aberration and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for high astigmatism. METHODS: In this retrospective case control study, 47 eyes with high astigmatism (≥ 2.5 D, HA group) and 47 eyes with low astigmatism (≤ 1.0 D, LA group) underwent FS-LASIK. Preoperative and follow-up examinations included visual outcomes, higher order aberrations (HOAs) and biomechanics. Biomechanical parameters include a deformation amplitude ratio of 2 mm (DA ratio 2 mm), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), and ambrosio relational thickness through the horizontal meridian (ARTh). RESULTS: Six months postoperatively, there was no significant difference in the efficacy and safety index (both P > 0.05) between the two groups, but the cylinder was higher in the HA group. The HOAs increased significantly after surgery in both groups (all P < 0.05). Six months postoperatively, the changes in spherical aberration and HOAs were larger in the HA group (both P < 0.005), but there was no significant difference between the changes in coma (P > 0.05). Significant decreases in SP-A1 and ARTh and significant increases in the IIR and DA ratio of 2 mm (all P < 0.05) were observed after surgery in both groups. The changes in the DA ratio 2 mm, IIR, SP-A1, and ARTh were not significantly different between the groups. CONCLUSION: FS-LASIK had relative comparable efficacy and safety in correcting high and low myopic astigmatism, with higher astigmatic under-correction in eyes with high astigmatism. High astigmatism in eyes after FS-LASIK could introduce larger corneal aberrations, but the impact on corneal stiffness was the same as that in eyes with low astigmatism. |
format | Online Article Text |
id | pubmed-9923895 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99238952023-02-14 Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study Li, Na Chen, Tong Tian, Ge Lin, Yue Meng, Yuan Gao, Hua Liu, Mingna BMC Ophthalmol Research BACKGROUND: To compare the 6-month changes in aberration and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for high astigmatism. METHODS: In this retrospective case control study, 47 eyes with high astigmatism (≥ 2.5 D, HA group) and 47 eyes with low astigmatism (≤ 1.0 D, LA group) underwent FS-LASIK. Preoperative and follow-up examinations included visual outcomes, higher order aberrations (HOAs) and biomechanics. Biomechanical parameters include a deformation amplitude ratio of 2 mm (DA ratio 2 mm), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), and ambrosio relational thickness through the horizontal meridian (ARTh). RESULTS: Six months postoperatively, there was no significant difference in the efficacy and safety index (both P > 0.05) between the two groups, but the cylinder was higher in the HA group. The HOAs increased significantly after surgery in both groups (all P < 0.05). Six months postoperatively, the changes in spherical aberration and HOAs were larger in the HA group (both P < 0.005), but there was no significant difference between the changes in coma (P > 0.05). Significant decreases in SP-A1 and ARTh and significant increases in the IIR and DA ratio of 2 mm (all P < 0.05) were observed after surgery in both groups. The changes in the DA ratio 2 mm, IIR, SP-A1, and ARTh were not significantly different between the groups. CONCLUSION: FS-LASIK had relative comparable efficacy and safety in correcting high and low myopic astigmatism, with higher astigmatic under-correction in eyes with high astigmatism. High astigmatism in eyes after FS-LASIK could introduce larger corneal aberrations, but the impact on corneal stiffness was the same as that in eyes with low astigmatism. BioMed Central 2023-02-13 /pmc/articles/PMC9923895/ /pubmed/36782180 http://dx.doi.org/10.1186/s12886-023-02809-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Li, Na Chen, Tong Tian, Ge Lin, Yue Meng, Yuan Gao, Hua Liu, Mingna Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study |
title | Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study |
title_full | Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study |
title_fullStr | Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study |
title_full_unstemmed | Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study |
title_short | Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study |
title_sort | changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (fs-lasik) in eyes with high astigmatism: a retrospective case control study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9923895/ https://www.ncbi.nlm.nih.gov/pubmed/36782180 http://dx.doi.org/10.1186/s12886-023-02809-4 |
work_keys_str_mv | AT lina changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy AT chentong changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy AT tiange changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy AT linyue changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy AT mengyuan changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy AT gaohua changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy AT liumingna changesinaberrationsandbiomechanicsafterfemtosecondlaserassistedlaserinsitukeratomileusisfslasikineyeswithhighastigmatismaretrospectivecasecontrolstudy |