Cargando…

Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study

BACKGROUND: Wearable resistance (WR) training is a modality that allows athletes to perform loaded sport-specific movements to develop force and power outputs. The acute responses by which WR works is still relatively unknown, and the effects of WR load and location of the load has not yet been exam...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, M, Giroux, C, Lacome, M, Leduc, C, Hader, K, Buchheit, M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: South African Sports Medicine Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9924529/
https://www.ncbi.nlm.nih.gov/pubmed/36815932
http://dx.doi.org/10.17159/2078-516X/2022/v34i1a13102
_version_ 1784887892573683712
author Brown, M
Giroux, C
Lacome, M
Leduc, C
Hader, K
Buchheit, M
author_facet Brown, M
Giroux, C
Lacome, M
Leduc, C
Hader, K
Buchheit, M
author_sort Brown, M
collection PubMed
description BACKGROUND: Wearable resistance (WR) training is a modality that allows athletes to perform loaded sport-specific movements to develop force and power outputs. The acute responses by which WR works is still relatively unknown, and the effects of WR load and location of the load has not yet been examined. OBJECTIVES: To investigate the acute neuromuscular and stride characteristic responses to different wearable resistance (WR) loads and placements on the calf muscles during high-speed running. METHODS: Ten well-trained subjects completed a workout of ten sets of three 10s runs at 18km.h(−1) (20s of rest between runs and one min between sets). Five conditions were tested: (1) unloaded control, (2) bilateral 0.75 vs. 1.5% body mass (BM) loading on the distal posterior calf, (3) bilateral proximal vs. distal loading of 1.5% BM positioned posteriorly, (4) bilateral anterior vs. posterior loading of 1.5% BM positioned distally, (5) unilateral loading of 1.5% BM on the distal posterior calf. Data were collected using Electromyography (EMG) and back-mounted GPS-embedded accelerometers. Magnitude of differences of within athlete and between muscle comparisons were calculated using effect sizes (ES) ± 90% confidence limits (CL). RESULTS: No substantial differences in accelerometry data were observed between any of the loaded conditions and the control. EMG activity was lower for proximal loading compared to the control for the gluteus maximus (ES±90%CL; −0.72±0.41), vastus lateralis (−0.89±0.47) and vastus medialis (VM) (−0.97±0.46). Anterior loading induced substantially lower EMG activity for the semitendinosus (−0.70±0.48) and VM (−0.64±0.39) muscles compared with the control. EMG activity of the VM (−0.73±0.46) muscle was also substantially lower for posterior loading compared to the control. Unilateral loading induced no substantial differences in EMG activity between the loaded and unloaded legs. CONCLUSION: This preliminary study has provided a rationale for the performance of further investigations into the effects of WR lower limb loading on stride characteristics and EMG activity from a chronic standpoint using a larger population.
format Online
Article
Text
id pubmed-9924529
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher South African Sports Medicine Association
record_format MEDLINE/PubMed
spelling pubmed-99245292023-02-16 Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study Brown, M Giroux, C Lacome, M Leduc, C Hader, K Buchheit, M S Afr J Sports Med Original Research BACKGROUND: Wearable resistance (WR) training is a modality that allows athletes to perform loaded sport-specific movements to develop force and power outputs. The acute responses by which WR works is still relatively unknown, and the effects of WR load and location of the load has not yet been examined. OBJECTIVES: To investigate the acute neuromuscular and stride characteristic responses to different wearable resistance (WR) loads and placements on the calf muscles during high-speed running. METHODS: Ten well-trained subjects completed a workout of ten sets of three 10s runs at 18km.h(−1) (20s of rest between runs and one min between sets). Five conditions were tested: (1) unloaded control, (2) bilateral 0.75 vs. 1.5% body mass (BM) loading on the distal posterior calf, (3) bilateral proximal vs. distal loading of 1.5% BM positioned posteriorly, (4) bilateral anterior vs. posterior loading of 1.5% BM positioned distally, (5) unilateral loading of 1.5% BM on the distal posterior calf. Data were collected using Electromyography (EMG) and back-mounted GPS-embedded accelerometers. Magnitude of differences of within athlete and between muscle comparisons were calculated using effect sizes (ES) ± 90% confidence limits (CL). RESULTS: No substantial differences in accelerometry data were observed between any of the loaded conditions and the control. EMG activity was lower for proximal loading compared to the control for the gluteus maximus (ES±90%CL; −0.72±0.41), vastus lateralis (−0.89±0.47) and vastus medialis (VM) (−0.97±0.46). Anterior loading induced substantially lower EMG activity for the semitendinosus (−0.70±0.48) and VM (−0.64±0.39) muscles compared with the control. EMG activity of the VM (−0.73±0.46) muscle was also substantially lower for posterior loading compared to the control. Unilateral loading induced no substantial differences in EMG activity between the loaded and unloaded legs. CONCLUSION: This preliminary study has provided a rationale for the performance of further investigations into the effects of WR lower limb loading on stride characteristics and EMG activity from a chronic standpoint using a larger population. South African Sports Medicine Association 2022-01-01 /pmc/articles/PMC9924529/ /pubmed/36815932 http://dx.doi.org/10.17159/2078-516X/2022/v34i1a13102 Text en https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Brown, M
Giroux, C
Lacome, M
Leduc, C
Hader, K
Buchheit, M
Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study
title Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study
title_full Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study
title_fullStr Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study
title_full_unstemmed Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study
title_short Effects of wearable resistance load placement on neuromuscular activity and stride kinematics: A preliminary study
title_sort effects of wearable resistance load placement on neuromuscular activity and stride kinematics: a preliminary study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9924529/
https://www.ncbi.nlm.nih.gov/pubmed/36815932
http://dx.doi.org/10.17159/2078-516X/2022/v34i1a13102
work_keys_str_mv AT brownm effectsofwearableresistanceloadplacementonneuromuscularactivityandstridekinematicsapreliminarystudy
AT girouxc effectsofwearableresistanceloadplacementonneuromuscularactivityandstridekinematicsapreliminarystudy
AT lacomem effectsofwearableresistanceloadplacementonneuromuscularactivityandstridekinematicsapreliminarystudy
AT leducc effectsofwearableresistanceloadplacementonneuromuscularactivityandstridekinematicsapreliminarystudy
AT haderk effectsofwearableresistanceloadplacementonneuromuscularactivityandstridekinematicsapreliminarystudy
AT buchheitm effectsofwearableresistanceloadplacementonneuromuscularactivityandstridekinematicsapreliminarystudy