Cargando…

Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study

PURPOSE: Osteoporosis-related proximal femur fractures continue to increase significantly due to demographic change. This study was designed to evaluate the biomechanical stability of two different fixation methods (cerclage vs. screw) for refixation of a trochanter minor fragment in the pertrochant...

Descripción completa

Detalles Bibliográficos
Autores principales: Linhart, Christoph, Kistler, Manuel, Woiczinski, Matthias, Neudeck, Rouven, Kassube, Matthias, Böcker, Wolfgang, Ehrnthaller, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9925468/
https://www.ncbi.nlm.nih.gov/pubmed/36167986
http://dx.doi.org/10.1007/s00068-022-02116-5
_version_ 1784888069349965824
author Linhart, Christoph
Kistler, Manuel
Woiczinski, Matthias
Neudeck, Rouven
Kassube, Matthias
Böcker, Wolfgang
Ehrnthaller, Christian
author_facet Linhart, Christoph
Kistler, Manuel
Woiczinski, Matthias
Neudeck, Rouven
Kassube, Matthias
Böcker, Wolfgang
Ehrnthaller, Christian
author_sort Linhart, Christoph
collection PubMed
description PURPOSE: Osteoporosis-related proximal femur fractures continue to increase significantly due to demographic change. This study was designed to evaluate the biomechanical stability of two different fixation methods (cerclage vs. screw) for refixation of a trochanter minor fragment in the pertrochanteric fractures in cadaveric bones. METHODS: Artificial bones (n = 14) and human bones (n = 16) were treated with a DHS and the trochanter minor fragment was reduced by cerclage wiring or direct screw fixation. After preloading the simulated iliopsoas with 10 N, a tensile test was performed, ending with either a 70% loss of strength or avulsion of the fragment. The mean values of the avulsion force and the surface strain were recorded. RESULTS: All tensile tests showed no significant differences between refixation using a direct screw or wire cerclage, for both artificial bones and human specimens. Absolute values showed higher avulsion forces after direct screw fixation than refixation with a wire cerclage. The surface tension of specimens treated with direct screw fixation was lower than that of specimens treated with wire cerclage. An opposite effect was seen in artificial bones. Both effects were not statistically significant. CONCLUSION: Based on the equal stability after lag screw placement compared to cerclage wiring, we promote the placement of a lag screw into the lesser trochanter fragment in pertrochanteric femur fractures when using a dynamic hip screw. LEVEL OF EVIDENCE: Level III.
format Online
Article
Text
id pubmed-9925468
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-99254682023-02-15 Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study Linhart, Christoph Kistler, Manuel Woiczinski, Matthias Neudeck, Rouven Kassube, Matthias Böcker, Wolfgang Ehrnthaller, Christian Eur J Trauma Emerg Surg Original Article PURPOSE: Osteoporosis-related proximal femur fractures continue to increase significantly due to demographic change. This study was designed to evaluate the biomechanical stability of two different fixation methods (cerclage vs. screw) for refixation of a trochanter minor fragment in the pertrochanteric fractures in cadaveric bones. METHODS: Artificial bones (n = 14) and human bones (n = 16) were treated with a DHS and the trochanter minor fragment was reduced by cerclage wiring or direct screw fixation. After preloading the simulated iliopsoas with 10 N, a tensile test was performed, ending with either a 70% loss of strength or avulsion of the fragment. The mean values of the avulsion force and the surface strain were recorded. RESULTS: All tensile tests showed no significant differences between refixation using a direct screw or wire cerclage, for both artificial bones and human specimens. Absolute values showed higher avulsion forces after direct screw fixation than refixation with a wire cerclage. The surface tension of specimens treated with direct screw fixation was lower than that of specimens treated with wire cerclage. An opposite effect was seen in artificial bones. Both effects were not statistically significant. CONCLUSION: Based on the equal stability after lag screw placement compared to cerclage wiring, we promote the placement of a lag screw into the lesser trochanter fragment in pertrochanteric femur fractures when using a dynamic hip screw. LEVEL OF EVIDENCE: Level III. Springer Berlin Heidelberg 2022-09-27 2023 /pmc/articles/PMC9925468/ /pubmed/36167986 http://dx.doi.org/10.1007/s00068-022-02116-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Linhart, Christoph
Kistler, Manuel
Woiczinski, Matthias
Neudeck, Rouven
Kassube, Matthias
Böcker, Wolfgang
Ehrnthaller, Christian
Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
title Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
title_full Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
title_fullStr Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
title_full_unstemmed Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
title_short Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
title_sort biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9925468/
https://www.ncbi.nlm.nih.gov/pubmed/36167986
http://dx.doi.org/10.1007/s00068-022-02116-5
work_keys_str_mv AT linhartchristoph biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy
AT kistlermanuel biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy
AT woiczinskimatthias biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy
AT neudeckrouven biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy
AT kassubematthias biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy
AT bockerwolfgang biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy
AT ehrnthallerchristian biomechanicalcomparisonofscrewvscerclagerefixationinorthogeriatriclessertrochantericfracturesacadavericstudy