Cargando…
Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up
BACKGROUND: There is currently no consensus regarding the preferred surgical procedure for the reconstruction of anterior cruciate ligament (ACL). The interference screw technique is widely used, but has been associated with a risk of graft damage. The Press-Fit-Hybrid®-technique is one of the alter...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9925573/ https://www.ncbi.nlm.nih.gov/pubmed/35290503 http://dx.doi.org/10.1007/s00402-022-04368-7 |
_version_ | 1784888093524885504 |
---|---|
author | Volz, Richard Borchert, Gudrun H. |
author_facet | Volz, Richard Borchert, Gudrun H. |
author_sort | Volz, Richard |
collection | PubMed |
description | BACKGROUND: There is currently no consensus regarding the preferred surgical procedure for the reconstruction of anterior cruciate ligament (ACL). The interference screw technique is widely used, but has been associated with a risk of graft damage. The Press-Fit-Hybrid®-technique is one of the alternatives for biological ACL-reconstruction with minimal implant requirements. The hypothesis of this retrospective analysis is, that the Press-Fit-Hybrid®-technique leads to better results with respect to re-rupture rate and secondary meniscal lesion than the interference-screw-technique. METHODS: To compare the re-rupture rate of the interference-screw-technique (IF) used until 2015 with the currently used Press-Fit-Hybrid®-technique (PFH), the last 100 patients of the IF-group and the first 100 patients of the PFH-group were retrospectively analyzed. Primary outcomes were re-rupture rate, complications and secondary meniscal injury. Additionally, laxity, Lachman and Pivot-shift and range of motion were evaluated. RESULTS: A mean follow-up of 4.2 and 5.3 years revealed 4% and 9% re-rupture rates and 1% and 2% complication rates in the PFH- and IF-group, respectively. In the PFH-group there were no re-ruptures in patients older than 23 years. Secondary meniscal injury post-surgery was 6% and 9% for the PFH and IF-group, respectively. Knee stability was similar in both groups. Range of motion was significantly better in the PFH-group, with 136° of flexion, 6 months after surgery. CONCLUSION: For ACL-reconstruction the Press-Fit-Hybrid®-technique is an alternative new method. Low level of secondary meniscal lesions after surgery and high stability, is known to prevent later arthrosis of the knee. The encouraging observed trend of the reduction of the re-rupture rate in revision surgery and in young patients using the Press-Fit-Hybrid®-technique in comparison to the interference-screw-technique must be confirmed with further studies. LEVEL OF EVIDENCE: Therapeutic Level III, retrospective cohort study. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00402-022-04368-7. |
format | Online Article Text |
id | pubmed-9925573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-99255732023-02-15 Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up Volz, Richard Borchert, Gudrun H. Arch Orthop Trauma Surg Arthroscopy and Sports Medicine BACKGROUND: There is currently no consensus regarding the preferred surgical procedure for the reconstruction of anterior cruciate ligament (ACL). The interference screw technique is widely used, but has been associated with a risk of graft damage. The Press-Fit-Hybrid®-technique is one of the alternatives for biological ACL-reconstruction with minimal implant requirements. The hypothesis of this retrospective analysis is, that the Press-Fit-Hybrid®-technique leads to better results with respect to re-rupture rate and secondary meniscal lesion than the interference-screw-technique. METHODS: To compare the re-rupture rate of the interference-screw-technique (IF) used until 2015 with the currently used Press-Fit-Hybrid®-technique (PFH), the last 100 patients of the IF-group and the first 100 patients of the PFH-group were retrospectively analyzed. Primary outcomes were re-rupture rate, complications and secondary meniscal injury. Additionally, laxity, Lachman and Pivot-shift and range of motion were evaluated. RESULTS: A mean follow-up of 4.2 and 5.3 years revealed 4% and 9% re-rupture rates and 1% and 2% complication rates in the PFH- and IF-group, respectively. In the PFH-group there were no re-ruptures in patients older than 23 years. Secondary meniscal injury post-surgery was 6% and 9% for the PFH and IF-group, respectively. Knee stability was similar in both groups. Range of motion was significantly better in the PFH-group, with 136° of flexion, 6 months after surgery. CONCLUSION: For ACL-reconstruction the Press-Fit-Hybrid®-technique is an alternative new method. Low level of secondary meniscal lesions after surgery and high stability, is known to prevent later arthrosis of the knee. The encouraging observed trend of the reduction of the re-rupture rate in revision surgery and in young patients using the Press-Fit-Hybrid®-technique in comparison to the interference-screw-technique must be confirmed with further studies. LEVEL OF EVIDENCE: Therapeutic Level III, retrospective cohort study. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00402-022-04368-7. Springer Berlin Heidelberg 2022-03-15 2023 /pmc/articles/PMC9925573/ /pubmed/35290503 http://dx.doi.org/10.1007/s00402-022-04368-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Arthroscopy and Sports Medicine Volz, Richard Borchert, Gudrun H. Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
title | Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
title_full | Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
title_fullStr | Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
title_full_unstemmed | Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
title_short | Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
title_sort | re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the press-fit-hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up |
topic | Arthroscopy and Sports Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9925573/ https://www.ncbi.nlm.nih.gov/pubmed/35290503 http://dx.doi.org/10.1007/s00402-022-04368-7 |
work_keys_str_mv | AT volzrichard rerupturerateandthepostsurgicalmeniscalinjuryafteranteriorcruciateligamentreconstructionwiththepressfithybridtechniqueincomparisontotheinterferencescrewtechniquearetrospectiveanalysisof200patientswithatleast3yearsfollowup AT borchertgudrunh rerupturerateandthepostsurgicalmeniscalinjuryafteranteriorcruciateligamentreconstructionwiththepressfithybridtechniqueincomparisontotheinterferencescrewtechniquearetrospectiveanalysisof200patientswithatleast3yearsfollowup |