Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?

INTRODUCTION: Blood samples having inappropriate volume are a substantial part of preanalytical errors. Inadequate sample volume for glycated haemoglobin (HbA1c) test may be a common problem of patients with diabetes mellitus having vascular changes. In this study, we compared HbA1c concentrations o...

Descripción completa

Detalles Bibliográficos
Autores principales: Guven, Berrak, Benice, Ismail, Can, Murat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9927728/
https://www.ncbi.nlm.nih.gov/pubmed/36817854
http://dx.doi.org/10.11613/BM.2023.010901
_version_ 1784888512485523456
author Guven, Berrak
Benice, Ismail
Can, Murat
author_facet Guven, Berrak
Benice, Ismail
Can, Murat
author_sort Guven, Berrak
collection PubMed
description INTRODUCTION: Blood samples having inappropriate volume are a substantial part of preanalytical errors. Inadequate sample volume for glycated haemoglobin (HbA1c) test may be a common problem of patients with diabetes mellitus having vascular changes. In this study, we compared HbA1c concentrations of underfilled and appropriately filled blood collection tubes. MATERIALS AND METHODS: To compare HbA1c concentrations, blood samples were collected into 2 mL tubes containing K3-EDTA from 109 subjects. Two blood samples (underfilled and appropriately filled) were drawn from a patient by the same personnel and materials. HbA1c measurements were assayed on a Cobas 6000 analyser module c 501 (Roche Diagnostics, Mannheim, Germany). The HbA1c% results were compared by t-test and Wilcoxon’s signed-rank statistical methods (SPSS Inc., Chicago, USA). Bias analysis was performed using Microsoft Excel 4.0. RESULTS: Underfilled samples were classified three groups (group 1, N = 44; group 2, N = 36; and group 3, N = 29) according to the filling ratio of the samples; 0.5 mL and below (< 25%), 0.5-1.0 mL (25-50%), and 1.0-2.0 mL (> 50%), respectively. When we compared underfilled tubes with pairing filled tubes, there was a statistically significant difference only with tubes filled less than 25% (P = 0.030). Furthermore, we have done bias analysis between paired tubes according to the diagnostic cut-off value of 6.5%. The bias was more prominent in up to 50% underfilled blood tubes (1.1%), when HbA1c concentrations were below the diagnostic cut-off of 6.5%. CONCLUSIONS: We suggest that the blood tubes with EDTA for HbA1c measurement should be filled with at least 50% to avoid clinical variations.
format Online
Article
Text
id pubmed-9927728
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-99277282023-02-16 Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay? Guven, Berrak Benice, Ismail Can, Murat Biochem Med (Zagreb) Short Communications INTRODUCTION: Blood samples having inappropriate volume are a substantial part of preanalytical errors. Inadequate sample volume for glycated haemoglobin (HbA1c) test may be a common problem of patients with diabetes mellitus having vascular changes. In this study, we compared HbA1c concentrations of underfilled and appropriately filled blood collection tubes. MATERIALS AND METHODS: To compare HbA1c concentrations, blood samples were collected into 2 mL tubes containing K3-EDTA from 109 subjects. Two blood samples (underfilled and appropriately filled) were drawn from a patient by the same personnel and materials. HbA1c measurements were assayed on a Cobas 6000 analyser module c 501 (Roche Diagnostics, Mannheim, Germany). The HbA1c% results were compared by t-test and Wilcoxon’s signed-rank statistical methods (SPSS Inc., Chicago, USA). Bias analysis was performed using Microsoft Excel 4.0. RESULTS: Underfilled samples were classified three groups (group 1, N = 44; group 2, N = 36; and group 3, N = 29) according to the filling ratio of the samples; 0.5 mL and below (< 25%), 0.5-1.0 mL (25-50%), and 1.0-2.0 mL (> 50%), respectively. When we compared underfilled tubes with pairing filled tubes, there was a statistically significant difference only with tubes filled less than 25% (P = 0.030). Furthermore, we have done bias analysis between paired tubes according to the diagnostic cut-off value of 6.5%. The bias was more prominent in up to 50% underfilled blood tubes (1.1%), when HbA1c concentrations were below the diagnostic cut-off of 6.5%. CONCLUSIONS: We suggest that the blood tubes with EDTA for HbA1c measurement should be filled with at least 50% to avoid clinical variations. Croatian Society of Medical Biochemistry and Laboratory Medicine 2023-02-15 2023-02-15 /pmc/articles/PMC9927728/ /pubmed/36817854 http://dx.doi.org/10.11613/BM.2023.010901 Text en Croatian Society of Medical Biochemistry and Laboratory Medicine. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communications
Guven, Berrak
Benice, Ismail
Can, Murat
Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
title Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
title_full Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
title_fullStr Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
title_full_unstemmed Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
title_short Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
title_sort undefilled blood tube containing edta: is it an inappropriate sample for hba1c assay?
topic Short Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9927728/
https://www.ncbi.nlm.nih.gov/pubmed/36817854
http://dx.doi.org/10.11613/BM.2023.010901
work_keys_str_mv AT guvenberrak undefilledbloodtubecontainingedtaisitaninappropriatesampleforhba1cassay
AT beniceismail undefilledbloodtubecontainingedtaisitaninappropriatesampleforhba1cassay
AT canmurat undefilledbloodtubecontainingedtaisitaninappropriatesampleforhba1cassay