Cargando…

Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room

To describe the clinical features and risk factors of device‐related pressure injuries (DRPIs) in the operating room. The clinical features of the DRPIs in patients undergoing elective surgery in a tertiary hospital in 2020 were investigated through prospective data collection. A DRPI‐related questi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Ling‐Yu, Chen, Hong‐Lin, Gu, Hai‐Yan, Hua, Li, Gao, Xiao‐Mei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9927895/
https://www.ncbi.nlm.nih.gov/pubmed/36787265
http://dx.doi.org/10.1111/iwj.13912
_version_ 1784888537845334016
author Ma, Ling‐Yu
Chen, Hong‐Lin
Gu, Hai‐Yan
Hua, Li
Gao, Xiao‐Mei
author_facet Ma, Ling‐Yu
Chen, Hong‐Lin
Gu, Hai‐Yan
Hua, Li
Gao, Xiao‐Mei
author_sort Ma, Ling‐Yu
collection PubMed
description To describe the clinical features and risk factors of device‐related pressure injuries (DRPIs) in the operating room. The clinical features of the DRPIs in patients undergoing elective surgery in a tertiary hospital in 2020 were investigated through prospective data collection. A DRPI‐related questionnaire was designed for the patients, and those who did not experience any DRPI were selected according to a ratio of 1:2. Logistic regression analysis was performed in terms of the independent risk factors of operating‐room DRPIs. A P‐value of <.05 indicated a statistically significant difference. The incidence of operating‐room DRPIs was 0.56%, and the proportion of stage I injuries was 73.53%. The injury‐related devices included vital monitoring devices (31.62%), auxiliary therapy devices (27.94%), therapy devices (19.12%), and dressings (3.67%). Non‐bone protuberances, such as the upper arms and thighs, were common injury sites. The patients' body mass index, mean arterial pressure, and instrument action time were independent risk factors for the operating‐room DRPIs. To reduce the incidence of operating‐room DRPIs, it is of great clinical significance to focus on the characteristics of the surgical patients and the types of surgery‐related devices used and to take personalised preventive measures based on the relevant risk factors.
format Online
Article
Text
id pubmed-9927895
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-99278952023-02-16 Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room Ma, Ling‐Yu Chen, Hong‐Lin Gu, Hai‐Yan Hua, Li Gao, Xiao‐Mei Int Wound J Original Articles To describe the clinical features and risk factors of device‐related pressure injuries (DRPIs) in the operating room. The clinical features of the DRPIs in patients undergoing elective surgery in a tertiary hospital in 2020 were investigated through prospective data collection. A DRPI‐related questionnaire was designed for the patients, and those who did not experience any DRPI were selected according to a ratio of 1:2. Logistic regression analysis was performed in terms of the independent risk factors of operating‐room DRPIs. A P‐value of <.05 indicated a statistically significant difference. The incidence of operating‐room DRPIs was 0.56%, and the proportion of stage I injuries was 73.53%. The injury‐related devices included vital monitoring devices (31.62%), auxiliary therapy devices (27.94%), therapy devices (19.12%), and dressings (3.67%). Non‐bone protuberances, such as the upper arms and thighs, were common injury sites. The patients' body mass index, mean arterial pressure, and instrument action time were independent risk factors for the operating‐room DRPIs. To reduce the incidence of operating‐room DRPIs, it is of great clinical significance to focus on the characteristics of the surgical patients and the types of surgery‐related devices used and to take personalised preventive measures based on the relevant risk factors. Blackwell Publishing Ltd 2022-08-19 /pmc/articles/PMC9927895/ /pubmed/36787265 http://dx.doi.org/10.1111/iwj.13912 Text en © 2022 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Ma, Ling‐Yu
Chen, Hong‐Lin
Gu, Hai‐Yan
Hua, Li
Gao, Xiao‐Mei
Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
title Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
title_full Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
title_fullStr Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
title_full_unstemmed Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
title_short Analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
title_sort analysis of the clinical features and risk factors of device‐related pressure injuries in the operating room
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9927895/
https://www.ncbi.nlm.nih.gov/pubmed/36787265
http://dx.doi.org/10.1111/iwj.13912
work_keys_str_mv AT malingyu analysisoftheclinicalfeaturesandriskfactorsofdevicerelatedpressureinjuriesintheoperatingroom
AT chenhonglin analysisoftheclinicalfeaturesandriskfactorsofdevicerelatedpressureinjuriesintheoperatingroom
AT guhaiyan analysisoftheclinicalfeaturesandriskfactorsofdevicerelatedpressureinjuriesintheoperatingroom
AT huali analysisoftheclinicalfeaturesandriskfactorsofdevicerelatedpressureinjuriesintheoperatingroom
AT gaoxiaomei analysisoftheclinicalfeaturesandriskfactorsofdevicerelatedpressureinjuriesintheoperatingroom