Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method

Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate...

Descripción completa

Detalles Bibliográficos
Autores principales: Entezam, Amir, Fielding, Andrew, Bradley, David, Fontanarosa, Davide
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9928120/
https://www.ncbi.nlm.nih.gov/pubmed/36730280
http://dx.doi.org/10.1371/journal.pone.0280765
_version_ 1784888589741457408
author Entezam, Amir
Fielding, Andrew
Bradley, David
Fontanarosa, Davide
author_facet Entezam, Amir
Fielding, Andrew
Bradley, David
Fontanarosa, Davide
author_sort Entezam, Amir
collection PubMed
description Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of D(max). Absorbed dose to the tumour varies in the range 60%-100% of D(max). DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
format Online
Article
Text
id pubmed-9928120
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-99281202023-02-15 Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method Entezam, Amir Fielding, Andrew Bradley, David Fontanarosa, Davide PLoS One Research Article Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of D(max). Absorbed dose to the tumour varies in the range 60%-100% of D(max). DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research. Public Library of Science 2023-02-02 /pmc/articles/PMC9928120/ /pubmed/36730280 http://dx.doi.org/10.1371/journal.pone.0280765 Text en © 2023 Entezam et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Entezam, Amir
Fielding, Andrew
Bradley, David
Fontanarosa, Davide
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_full Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_fullStr Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_full_unstemmed Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_short Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_sort absorbed dose calculation for a realistic ct-derived mouse phantom irradiated with a standard cs-137 cell irradiator using a monte carlo method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9928120/
https://www.ncbi.nlm.nih.gov/pubmed/36730280
http://dx.doi.org/10.1371/journal.pone.0280765
work_keys_str_mv AT entezamamir absorbeddosecalculationforarealisticctderivedmousephantomirradiatedwithastandardcs137cellirradiatorusingamontecarlomethod
AT fieldingandrew absorbeddosecalculationforarealisticctderivedmousephantomirradiatedwithastandardcs137cellirradiatorusingamontecarlomethod
AT bradleydavid absorbeddosecalculationforarealisticctderivedmousephantomirradiatedwithastandardcs137cellirradiatorusingamontecarlomethod
AT fontanarosadavide absorbeddosecalculationforarealisticctderivedmousephantomirradiatedwithastandardcs137cellirradiatorusingamontecarlomethod