Cargando…
Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position
BACKGROUND: The use of coring instrumentation for osteochondral allograft (OCA) transplantation of the femoral trochlea is challenging due to the complex topography of this anatomical area. PURPOSE: We sought to determine the effect of flat guides versus guides contoured to the surface of the trochl...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9929919/ https://www.ncbi.nlm.nih.gov/pubmed/36818603 http://dx.doi.org/10.1177/23259671221145208 |
_version_ | 1784888952694505472 |
---|---|
author | Delman, Connor M. Haffner, Max Rinaldi, Peter Lum, Zach C. Jamali, Amir A. Wilson, Machelle Lee, Cassandra A. |
author_facet | Delman, Connor M. Haffner, Max Rinaldi, Peter Lum, Zach C. Jamali, Amir A. Wilson, Machelle Lee, Cassandra A. |
author_sort | Delman, Connor M. |
collection | PubMed |
description | BACKGROUND: The use of coring instrumentation for osteochondral allograft (OCA) transplantation of the femoral trochlea is challenging due to the complex topography of this anatomical area. PURPOSE: We sought to determine the effect of flat guides versus guides contoured to the surface of the trochlea on graft step-off in trochlear OCAs performed on a foam bone model. We also determined the effect of surgeon experience level and graft size on step-off. STUDY DESIGN: Controlled laboratory study. METHODS: Allograft harvesters were produced in 3 different sequential sizes with either a flat or a contoured undersurface. The guides matched one another in all aspects of shape and size except for the undersurface contour. The contoured undersurface generally matched the surface of the bone model trochlea but was not customized to that surface. A total of 72 foam femora were obtained. Identical trochlear stellate lesions of 3 different sizes (small, medium, and large) were created using 3-dimensional printed surface templates. A total of 6 surgeons (3 attending and 3 resident surgeons) performed OCAs of each trochlear lesion. Each surgeon performed 1 graft for each size and each guide type (n = 6 per surgeon). A specialized digital caliper was prepared that allowed the measurement of graft step-off to within 0.01 mm at a distance of 5 mm between the 2 sensors. The measurements were performed at 8 positions around the clockface of the grafts. RESULTS: Grafts performed with the contoured guides had a mean step-off of 0.43 ± 0.37 mm. Grafts performed with the flat guides had a mean step-off of 0.74 ± 0.78 mm (P < .0001). Experience level did not have a significant effect on graft step-off (P = .81). There was no identifiable pattern indicating higher step-off at any one position on the clockface. CONCLUSION: In this study, contoured grafts had significantly lower step-offs compared with flat guides. Experience level, clockface position, and graft size did not affect step-off. |
format | Online Article Text |
id | pubmed-9929919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-99299192023-02-16 Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position Delman, Connor M. Haffner, Max Rinaldi, Peter Lum, Zach C. Jamali, Amir A. Wilson, Machelle Lee, Cassandra A. Orthop J Sports Med Article BACKGROUND: The use of coring instrumentation for osteochondral allograft (OCA) transplantation of the femoral trochlea is challenging due to the complex topography of this anatomical area. PURPOSE: We sought to determine the effect of flat guides versus guides contoured to the surface of the trochlea on graft step-off in trochlear OCAs performed on a foam bone model. We also determined the effect of surgeon experience level and graft size on step-off. STUDY DESIGN: Controlled laboratory study. METHODS: Allograft harvesters were produced in 3 different sequential sizes with either a flat or a contoured undersurface. The guides matched one another in all aspects of shape and size except for the undersurface contour. The contoured undersurface generally matched the surface of the bone model trochlea but was not customized to that surface. A total of 72 foam femora were obtained. Identical trochlear stellate lesions of 3 different sizes (small, medium, and large) were created using 3-dimensional printed surface templates. A total of 6 surgeons (3 attending and 3 resident surgeons) performed OCAs of each trochlear lesion. Each surgeon performed 1 graft for each size and each guide type (n = 6 per surgeon). A specialized digital caliper was prepared that allowed the measurement of graft step-off to within 0.01 mm at a distance of 5 mm between the 2 sensors. The measurements were performed at 8 positions around the clockface of the grafts. RESULTS: Grafts performed with the contoured guides had a mean step-off of 0.43 ± 0.37 mm. Grafts performed with the flat guides had a mean step-off of 0.74 ± 0.78 mm (P < .0001). Experience level did not have a significant effect on graft step-off (P = .81). There was no identifiable pattern indicating higher step-off at any one position on the clockface. CONCLUSION: In this study, contoured grafts had significantly lower step-offs compared with flat guides. Experience level, clockface position, and graft size did not affect step-off. SAGE Publications 2023-02-13 /pmc/articles/PMC9929919/ /pubmed/36818603 http://dx.doi.org/10.1177/23259671221145208 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Article Delman, Connor M. Haffner, Max Rinaldi, Peter Lum, Zach C. Jamali, Amir A. Wilson, Machelle Lee, Cassandra A. Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position |
title | Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position |
title_full | Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position |
title_fullStr | Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position |
title_full_unstemmed | Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position |
title_short | Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position |
title_sort | improving technical outcome in osteochondral allograft transplantation of the femoral trochlea: the role of contoured guides, experience level, graft size, and graft position |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9929919/ https://www.ncbi.nlm.nih.gov/pubmed/36818603 http://dx.doi.org/10.1177/23259671221145208 |
work_keys_str_mv | AT delmanconnorm improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition AT haffnermax improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition AT rinaldipeter improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition AT lumzachc improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition AT jamaliamira improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition AT wilsonmachelle improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition AT leecassandraa improvingtechnicaloutcomeinosteochondralallografttransplantationofthefemoraltrochleatheroleofcontouredguidesexperiencelevelgraftsizeandgraftposition |