Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study

OBJECTIVES: Ultrasound (US) airway indexes were frequently compared with other scoring systems such as Mallampati score and Cormack − Lehane classification system, but to the best of our knowledge never with LEMON. Here, in this study, we evaluated the accuracy of some recommended airway US paramete...

Descripción completa

Detalles Bibliográficos
Autores principales: Sotoodehnia, Mehran, Abbasi, Najmeh, Bahri, Razman Arabzadeh, Abdollahi, Atefeh, Baratloo, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9930393/
https://www.ncbi.nlm.nih.gov/pubmed/36818949
http://dx.doi.org/10.4103/2452-2473.366484
_version_ 1784889039818588160
author Sotoodehnia, Mehran
Abbasi, Najmeh
Bahri, Razman Arabzadeh
Abdollahi, Atefeh
Baratloo, Alireza
author_facet Sotoodehnia, Mehran
Abbasi, Najmeh
Bahri, Razman Arabzadeh
Abdollahi, Atefeh
Baratloo, Alireza
author_sort Sotoodehnia, Mehran
collection PubMed
description OBJECTIVES: Ultrasound (US) airway indexes were frequently compared with other scoring systems such as Mallampati score and Cormack − Lehane classification system, but to the best of our knowledge never with LEMON. Here, in this study, we evaluated the accuracy of some recommended airway US parameters in terms of screening difficult airway using the LEMON criteria as a reference. METHODS: This was a cross-sectional diagnostic accuracy study in which people with at least 18 years old coming to the emergency departments for any reason who had consent for participation, were enrolled with the simple random sampling method. Hyo-mental distance (HMD), skin to epiglottis distance (EP), and peri-epiglottic space to epiglottis to vocal cord ratio (PEP/E. VC) were the US indexes that were calculated in all participants. Using a preprepared checklist, measured US parameters were recorded. For each participant, the LEMON score variables were also assessed and recorded, and the cutoff point for considering as a difficult airway case, based on LEMON score, was 2. Demographic characteristics of the participants were also registered. RESULTS: A total of 299 cases with a mean age of 41.1 years (95% confidence interval [CI]: 39.3–42.9), were participated. Based on LEMON score ≥2, 20 participants (6.7%) were categorized in difficult airway group. Comparison of the PEP/E. VC (P = 0.007) and EP distance (P = 0.049) of the participants based on LEMON score showed a statistically significant difference; but comparison of the means of HMD in the two groups was not statistically significant (P = 0.144). The median of EP of the participants was 7.70 mm (interquartile range [IQR]: 6.70–9.40). The best cutoff point of EP distance for evaluating a difficult airway was 12.27 mm and more with the sensitivity of 35% and the specificity of 86.96% (accuracy = 0.614; 95% CI: 0.492–0.736). The median of PEP/E. VC was 1.01(IQR: 0.79–1.23). The best cutoff point of PEP/E. VC for evaluating a difficult airway was 0.88 and less with the sensitivity of 70% and the specificity of 67.38% (accuracy = 0.701; 95% CI: 0.583–0.818). CONCLUSION: As per our results, PEP/E. VC and EP distance measured with sonography can be used in distinguishing the difficult airway, using the LEMON criteria as the reference. However, further studies are needed to use PEP/E. VC and EP distance as a part of reliable indexes.
format Online
Article
Text
id pubmed-9930393
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-99303932023-02-16 Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study Sotoodehnia, Mehran Abbasi, Najmeh Bahri, Razman Arabzadeh Abdollahi, Atefeh Baratloo, Alireza Turk J Emerg Med Original Article OBJECTIVES: Ultrasound (US) airway indexes were frequently compared with other scoring systems such as Mallampati score and Cormack − Lehane classification system, but to the best of our knowledge never with LEMON. Here, in this study, we evaluated the accuracy of some recommended airway US parameters in terms of screening difficult airway using the LEMON criteria as a reference. METHODS: This was a cross-sectional diagnostic accuracy study in which people with at least 18 years old coming to the emergency departments for any reason who had consent for participation, were enrolled with the simple random sampling method. Hyo-mental distance (HMD), skin to epiglottis distance (EP), and peri-epiglottic space to epiglottis to vocal cord ratio (PEP/E. VC) were the US indexes that were calculated in all participants. Using a preprepared checklist, measured US parameters were recorded. For each participant, the LEMON score variables were also assessed and recorded, and the cutoff point for considering as a difficult airway case, based on LEMON score, was 2. Demographic characteristics of the participants were also registered. RESULTS: A total of 299 cases with a mean age of 41.1 years (95% confidence interval [CI]: 39.3–42.9), were participated. Based on LEMON score ≥2, 20 participants (6.7%) were categorized in difficult airway group. Comparison of the PEP/E. VC (P = 0.007) and EP distance (P = 0.049) of the participants based on LEMON score showed a statistically significant difference; but comparison of the means of HMD in the two groups was not statistically significant (P = 0.144). The median of EP of the participants was 7.70 mm (interquartile range [IQR]: 6.70–9.40). The best cutoff point of EP distance for evaluating a difficult airway was 12.27 mm and more with the sensitivity of 35% and the specificity of 86.96% (accuracy = 0.614; 95% CI: 0.492–0.736). The median of PEP/E. VC was 1.01(IQR: 0.79–1.23). The best cutoff point of PEP/E. VC for evaluating a difficult airway was 0.88 and less with the sensitivity of 70% and the specificity of 67.38% (accuracy = 0.701; 95% CI: 0.583–0.818). CONCLUSION: As per our results, PEP/E. VC and EP distance measured with sonography can be used in distinguishing the difficult airway, using the LEMON criteria as the reference. However, further studies are needed to use PEP/E. VC and EP distance as a part of reliable indexes. Wolters Kluwer - Medknow 2023-01-02 /pmc/articles/PMC9930393/ /pubmed/36818949 http://dx.doi.org/10.4103/2452-2473.366484 Text en Copyright: © 2023 Turkish Journal of Emergency Medicine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sotoodehnia, Mehran
Abbasi, Najmeh
Bahri, Razman Arabzadeh
Abdollahi, Atefeh
Baratloo, Alireza
Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study
title Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study
title_full Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study
title_fullStr Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study
title_full_unstemmed Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study
title_short Accuracy of airway ultrasound parameters to predict difficult airway using the LEMON criteria as a reference: A cross-sectional diagnostic accuracy study
title_sort accuracy of airway ultrasound parameters to predict difficult airway using the lemon criteria as a reference: a cross-sectional diagnostic accuracy study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9930393/
https://www.ncbi.nlm.nih.gov/pubmed/36818949
http://dx.doi.org/10.4103/2452-2473.366484
work_keys_str_mv AT sotoodehniamehran accuracyofairwayultrasoundparameterstopredictdifficultairwayusingthelemoncriteriaasareferenceacrosssectionaldiagnosticaccuracystudy
AT abbasinajmeh accuracyofairwayultrasoundparameterstopredictdifficultairwayusingthelemoncriteriaasareferenceacrosssectionaldiagnosticaccuracystudy
AT bahrirazmanarabzadeh accuracyofairwayultrasoundparameterstopredictdifficultairwayusingthelemoncriteriaasareferenceacrosssectionaldiagnosticaccuracystudy
AT abdollahiatefeh accuracyofairwayultrasoundparameterstopredictdifficultairwayusingthelemoncriteriaasareferenceacrosssectionaldiagnosticaccuracystudy
AT baratlooalireza accuracyofairwayultrasoundparameterstopredictdifficultairwayusingthelemoncriteriaasareferenceacrosssectionaldiagnosticaccuracystudy