Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors

To compare the enlargement of the clear corneal incision from IOL implantation with 2 different intraocular lens (IOL) injectors: the AutonoMe preloaded with the Clareon IOL and the Multisert preloaded with the Vivinex IOL. SETTING: The David J. Apple Center for Vision Research, Department of Ophtha...

Descripción completa

Detalles Bibliográficos
Autores principales: Khoramnia, Ramin, Baur, Isabella D., Łabuz, Grzegorz, Chychko, Lizaveta, Köppe, Maximilian K., Hallak, Mustafa K., Auffarth, Gerd U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9930886/
https://www.ncbi.nlm.nih.gov/pubmed/36209736
http://dx.doi.org/10.1097/j.jcrs.0000000000001064
_version_ 1784889126112198656
author Khoramnia, Ramin
Baur, Isabella D.
Łabuz, Grzegorz
Chychko, Lizaveta
Köppe, Maximilian K.
Hallak, Mustafa K.
Auffarth, Gerd U.
author_facet Khoramnia, Ramin
Baur, Isabella D.
Łabuz, Grzegorz
Chychko, Lizaveta
Köppe, Maximilian K.
Hallak, Mustafa K.
Auffarth, Gerd U.
author_sort Khoramnia, Ramin
collection PubMed
description To compare the enlargement of the clear corneal incision from IOL implantation with 2 different intraocular lens (IOL) injectors: the AutonoMe preloaded with the Clareon IOL and the Multisert preloaded with the Vivinex IOL. SETTING: The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN: Prospective randomized clinical comparative study. METHODS: 96 eyes of 48 patients with cataract were intraindividually randomized to treatment with 1 of the 2 injectors. For Multisert eyes, the insert shield (IS) was used in the advanced position in 23 eyes. The initial incision was 2.2 mm, and intraoperative measurements of the incision size were made before and after IOL injection. 3 months postoperatively, keratometry and uncorrected (UDVA) and corrected (CDVA) distance visual acuities were assessed. RESULTS: Results are reported for 96 eyes of 48 patients. The mean incision enlargement was 0.213 ± 0.068 mm in the Multisert with the IS group, 0.265 ± 0.055 mm in the fellow eyes (AutonoMe) (P < .05), 0.272 ± 0.060 mm in Multisert eyes treated without the IS, and 0.296 ± 0.066 mm for the fellow eyes (AutonoMe) (P > .05). The mean absolute surgically induced astigmatism was 0.42 ± 0.23 diopters (D), 0.50 ± 0.25 D, and 0.44 ± 0.18 D in the Multisert with the IS, Multisert without the IS, and AutonoMe group, respectively (P > .05). The UDVA and CDVA were comparable in all groups. CONCLUSIONS: The Multisert was associated with less wound enlargement than the AutonoMe. All groups had comparable functional outcomes. Therefore, the observed difference in incision enlargement may be of limited clinical relevance.
format Online
Article
Text
id pubmed-9930886
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer
record_format MEDLINE/PubMed
spelling pubmed-99308862023-02-16 Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors Khoramnia, Ramin Baur, Isabella D. Łabuz, Grzegorz Chychko, Lizaveta Köppe, Maximilian K. Hallak, Mustafa K. Auffarth, Gerd U. J Cataract Refract Surg Article To compare the enlargement of the clear corneal incision from IOL implantation with 2 different intraocular lens (IOL) injectors: the AutonoMe preloaded with the Clareon IOL and the Multisert preloaded with the Vivinex IOL. SETTING: The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN: Prospective randomized clinical comparative study. METHODS: 96 eyes of 48 patients with cataract were intraindividually randomized to treatment with 1 of the 2 injectors. For Multisert eyes, the insert shield (IS) was used in the advanced position in 23 eyes. The initial incision was 2.2 mm, and intraoperative measurements of the incision size were made before and after IOL injection. 3 months postoperatively, keratometry and uncorrected (UDVA) and corrected (CDVA) distance visual acuities were assessed. RESULTS: Results are reported for 96 eyes of 48 patients. The mean incision enlargement was 0.213 ± 0.068 mm in the Multisert with the IS group, 0.265 ± 0.055 mm in the fellow eyes (AutonoMe) (P < .05), 0.272 ± 0.060 mm in Multisert eyes treated without the IS, and 0.296 ± 0.066 mm for the fellow eyes (AutonoMe) (P > .05). The mean absolute surgically induced astigmatism was 0.42 ± 0.23 diopters (D), 0.50 ± 0.25 D, and 0.44 ± 0.18 D in the Multisert with the IS, Multisert without the IS, and AutonoMe group, respectively (P > .05). The UDVA and CDVA were comparable in all groups. CONCLUSIONS: The Multisert was associated with less wound enlargement than the AutonoMe. All groups had comparable functional outcomes. Therefore, the observed difference in incision enlargement may be of limited clinical relevance. Wolters Kluwer 2023-02 2022-10-05 /pmc/articles/PMC9930886/ /pubmed/36209736 http://dx.doi.org/10.1097/j.jcrs.0000000000001064 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of ASCRS and ESCRS https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Article
Khoramnia, Ramin
Baur, Isabella D.
Łabuz, Grzegorz
Chychko, Lizaveta
Köppe, Maximilian K.
Hallak, Mustafa K.
Auffarth, Gerd U.
Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
title Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
title_full Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
title_fullStr Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
title_full_unstemmed Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
title_short Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
title_sort enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9930886/
https://www.ncbi.nlm.nih.gov/pubmed/36209736
http://dx.doi.org/10.1097/j.jcrs.0000000000001064
work_keys_str_mv AT khoramniaramin enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors
AT baurisabellad enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors
AT łabuzgrzegorz enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors
AT chychkolizaveta enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors
AT koppemaximiliank enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors
AT hallakmustafak enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors
AT auffarthgerdu enlargementofmaincornealincisionclinicalintraindividualcomparisonoftwopreloadedintraocularlensinjectors