Cargando…

Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS

Fragrances are the most common chemicals in cosmetics to which people expose every day. However, the unwanted allergic reactions such as contact dermatitis caused by direct contact with fragrances may happen. In Directive 2003/15/EC of the EU, cosmetic product containing one or more of 26 fragrance...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Chia-Hui, Fang, Ming-Chih, Chen, Yu-Zi, Huang, Shou-Chieh, Wang, Der-Yuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taiwan Food and Drug Administration 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931019/
https://www.ncbi.nlm.nih.gov/pubmed/35649135
http://dx.doi.org/10.38212/2224-6614.3373
_version_ 1784889157216108544
author Lu, Chia-Hui
Fang, Ming-Chih
Chen, Yu-Zi
Huang, Shou-Chieh
Wang, Der-Yuan
author_facet Lu, Chia-Hui
Fang, Ming-Chih
Chen, Yu-Zi
Huang, Shou-Chieh
Wang, Der-Yuan
author_sort Lu, Chia-Hui
collection PubMed
description Fragrances are the most common chemicals in cosmetics to which people expose every day. However, the unwanted allergic reactions such as contact dermatitis caused by direct contact with fragrances may happen. In Directive 2003/15/EC of the EU, cosmetic product containing one or more of 26 fragrance allergens must be declared on the package label. In addition, commission regulation (EU) 2017/1410 amending Annexes II and III of cosmetic regulation 1223/2009 restricted fragrance chemical of methyl eugenol, and prohibited Lyral, atranol, chloroatranol to be used in cosmetic. In this study, an efficient and sensitive GC–MS method for 3 banned fragrances, 26 fragrance allergens along with restricted methyl eugenol in cosmetics was established. Sample preparation by liquid–liquid extraction was developed by testing various solvent systems to simplify traditional complex extraction methodologies. Validation of the proposed method showed good linearities in a wide concentration ranges of 0.1–10 μg/mL. The intra-day and inter-day recoveries were between 84.4 and 119% with coefficient of variation (CV) below 13.5%. The limit of quantifications (LOQs) of 27 fragrance allergens were in the range of 2–20 μg/g. A surveillance study consisted with 82 cosmetics was conducted, among which 31 products claimed fragrance-free. The results showed some fragrance-free claims were false. In the other hand, there were seven cosmetics labeled containing Lyral, but only four were detected. The top fragrance allergens detected in the samples were linalool, limonene, and geraniol. The analysis of fragrance allergens in cosmetics indicated that potential contact allergy related to these products should be considered, even though some fragrance allergens were from natural extracts, such as oak moss absolute.
format Online
Article
Text
id pubmed-9931019
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Taiwan Food and Drug Administration
record_format MEDLINE/PubMed
spelling pubmed-99310192023-02-16 Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS Lu, Chia-Hui Fang, Ming-Chih Chen, Yu-Zi Huang, Shou-Chieh Wang, Der-Yuan J Food Drug Anal Original Article Fragrances are the most common chemicals in cosmetics to which people expose every day. However, the unwanted allergic reactions such as contact dermatitis caused by direct contact with fragrances may happen. In Directive 2003/15/EC of the EU, cosmetic product containing one or more of 26 fragrance allergens must be declared on the package label. In addition, commission regulation (EU) 2017/1410 amending Annexes II and III of cosmetic regulation 1223/2009 restricted fragrance chemical of methyl eugenol, and prohibited Lyral, atranol, chloroatranol to be used in cosmetic. In this study, an efficient and sensitive GC–MS method for 3 banned fragrances, 26 fragrance allergens along with restricted methyl eugenol in cosmetics was established. Sample preparation by liquid–liquid extraction was developed by testing various solvent systems to simplify traditional complex extraction methodologies. Validation of the proposed method showed good linearities in a wide concentration ranges of 0.1–10 μg/mL. The intra-day and inter-day recoveries were between 84.4 and 119% with coefficient of variation (CV) below 13.5%. The limit of quantifications (LOQs) of 27 fragrance allergens were in the range of 2–20 μg/g. A surveillance study consisted with 82 cosmetics was conducted, among which 31 products claimed fragrance-free. The results showed some fragrance-free claims were false. In the other hand, there were seven cosmetics labeled containing Lyral, but only four were detected. The top fragrance allergens detected in the samples were linalool, limonene, and geraniol. The analysis of fragrance allergens in cosmetics indicated that potential contact allergy related to these products should be considered, even though some fragrance allergens were from natural extracts, such as oak moss absolute. Taiwan Food and Drug Administration 2021-12-15 /pmc/articles/PMC9931019/ /pubmed/35649135 http://dx.doi.org/10.38212/2224-6614.3373 Text en © 2021 Taiwan Food and Drug Administration https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Original Article
Lu, Chia-Hui
Fang, Ming-Chih
Chen, Yu-Zi
Huang, Shou-Chieh
Wang, Der-Yuan
Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS
title Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS
title_full Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS
title_fullStr Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS
title_full_unstemmed Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS
title_short Quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and GC–MS
title_sort quantitative analysis of fragrance allergens in various matrixes of cosmetics by liquid–liquid extraction and gc–ms
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931019/
https://www.ncbi.nlm.nih.gov/pubmed/35649135
http://dx.doi.org/10.38212/2224-6614.3373
work_keys_str_mv AT luchiahui quantitativeanalysisoffragranceallergensinvariousmatrixesofcosmeticsbyliquidliquidextractionandgcms
AT fangmingchih quantitativeanalysisoffragranceallergensinvariousmatrixesofcosmeticsbyliquidliquidextractionandgcms
AT chenyuzi quantitativeanalysisoffragranceallergensinvariousmatrixesofcosmeticsbyliquidliquidextractionandgcms
AT huangshouchieh quantitativeanalysisoffragranceallergensinvariousmatrixesofcosmeticsbyliquidliquidextractionandgcms
AT wangderyuan quantitativeanalysisoffragranceallergensinvariousmatrixesofcosmeticsbyliquidliquidextractionandgcms