Cargando…
The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study
BACKGROUND: The hospital environment, particularly the intensive care unit (ICU), contributes to the transmission of several nosocomial pathogens, which can survive in this setting for a longer period of time and, in turn, contaminate the surfaces or the medical tools. Thus, appropriate disinfection...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931129/ https://www.ncbi.nlm.nih.gov/pubmed/36791118 http://dx.doi.org/10.1371/journal.pone.0281802 |
_version_ | 1784889179645149184 |
---|---|
author | Li, Jing Zhang, Yanhua Zhang, Zhiyun Zhang, Haixia Wang, Xiaojuan Wang, Fuchuan Wang, Hongyu Chen, Meiling |
author_facet | Li, Jing Zhang, Yanhua Zhang, Zhiyun Zhang, Haixia Wang, Xiaojuan Wang, Fuchuan Wang, Hongyu Chen, Meiling |
author_sort | Li, Jing |
collection | PubMed |
description | BACKGROUND: The hospital environment, particularly the intensive care unit (ICU), contributes to the transmission of several nosocomial pathogens, which can survive in this setting for a longer period of time and, in turn, contaminate the surfaces or the medical tools. Thus, appropriate disinfection of these areas and devices are crucial for controlling and preventing further infection. In this study, we examined the effect of different concentrations of chlorine-containing disinfectants (500mg/L, 1000mg/L, and 2000mg/L) on the ICU environment. METHODS: This quasi-experimental study was based on a convenient sampling method. In this study, High-frequency objects were selected as subjects in ICU, with a total sample of 216.A hall including 6 beds was examined,selecting 4 high-frequency surfaces per bed unit:a bed gear, infusion system, bed end table, and monitor were disinfected with 500, 1000, and 2000 mg/L of chlorine (as Cl2), respectively.The surface dissection was performed at 21:00 o’clock daily, after which ATP fluorescence monitoring and bacterial count detection were performed. RESULTS: There was no significant difference in ATP bioluminescence (F = 2.03, P > 0.05) and bacterial counting (χ2 = 2.03, P > 0.05) when using different concentrations of chlorine-containing disinfectant in the ICU. Yet, compared with high concentration (2000mg/L), a low concentration disinfectant reduced the hospital cost. CONCLUSION: By reducing the concentration of ICU high-frequency contact table disinfectants, it is possible to reduce the risk of long-term contamination with chlorine-containing disinfectants and reduce the cost of using ICU chlorine-containing disinfectants. |
format | Online Article Text |
id | pubmed-9931129 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-99311292023-02-16 The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study Li, Jing Zhang, Yanhua Zhang, Zhiyun Zhang, Haixia Wang, Xiaojuan Wang, Fuchuan Wang, Hongyu Chen, Meiling PLoS One Research Article BACKGROUND: The hospital environment, particularly the intensive care unit (ICU), contributes to the transmission of several nosocomial pathogens, which can survive in this setting for a longer period of time and, in turn, contaminate the surfaces or the medical tools. Thus, appropriate disinfection of these areas and devices are crucial for controlling and preventing further infection. In this study, we examined the effect of different concentrations of chlorine-containing disinfectants (500mg/L, 1000mg/L, and 2000mg/L) on the ICU environment. METHODS: This quasi-experimental study was based on a convenient sampling method. In this study, High-frequency objects were selected as subjects in ICU, with a total sample of 216.A hall including 6 beds was examined,selecting 4 high-frequency surfaces per bed unit:a bed gear, infusion system, bed end table, and monitor were disinfected with 500, 1000, and 2000 mg/L of chlorine (as Cl2), respectively.The surface dissection was performed at 21:00 o’clock daily, after which ATP fluorescence monitoring and bacterial count detection were performed. RESULTS: There was no significant difference in ATP bioluminescence (F = 2.03, P > 0.05) and bacterial counting (χ2 = 2.03, P > 0.05) when using different concentrations of chlorine-containing disinfectant in the ICU. Yet, compared with high concentration (2000mg/L), a low concentration disinfectant reduced the hospital cost. CONCLUSION: By reducing the concentration of ICU high-frequency contact table disinfectants, it is possible to reduce the risk of long-term contamination with chlorine-containing disinfectants and reduce the cost of using ICU chlorine-containing disinfectants. Public Library of Science 2023-02-15 /pmc/articles/PMC9931129/ /pubmed/36791118 http://dx.doi.org/10.1371/journal.pone.0281802 Text en © 2023 Li et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Li, Jing Zhang, Yanhua Zhang, Zhiyun Zhang, Haixia Wang, Xiaojuan Wang, Fuchuan Wang, Hongyu Chen, Meiling The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study |
title | The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study |
title_full | The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study |
title_fullStr | The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study |
title_full_unstemmed | The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study |
title_short | The effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: A quasi-experimental study |
title_sort | effect of different concentrations of chlorine-containing disinfectants on high-frequency contact table in intensive care units: a quasi-experimental study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931129/ https://www.ncbi.nlm.nih.gov/pubmed/36791118 http://dx.doi.org/10.1371/journal.pone.0281802 |
work_keys_str_mv | AT lijing theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT zhangyanhua theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT zhangzhiyun theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT zhanghaixia theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT wangxiaojuan theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT wangfuchuan theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT wanghongyu theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT chenmeiling theeffectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT lijing effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT zhangyanhua effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT zhangzhiyun effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT zhanghaixia effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT wangxiaojuan effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT wangfuchuan effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT wanghongyu effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy AT chenmeiling effectofdifferentconcentrationsofchlorinecontainingdisinfectantsonhighfrequencycontacttableinintensivecareunitsaquasiexperimentalstudy |