Cargando…

Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction

Significant lead-induced tricuspid regurgitation after cardiovascular implantable electronic devices is not uncommon. Absolute or relative contraindications to place the lead in the right ventricle after tricuspid valve (TV) surgery still remains a challenge. We report about successful lead extracti...

Descripción completa

Detalles Bibliográficos
Autores principales: Gruszczynski, M., Müller-Burri, A., Häussler, A., Breitenstein, A., Rodriguez Cetina Biefer, H., Dzemali, O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931479/
https://www.ncbi.nlm.nih.gov/pubmed/36819941
http://dx.doi.org/10.1155/2023/6646224
_version_ 1784889259393548288
author Gruszczynski, M.
Müller-Burri, A.
Häussler, A.
Breitenstein, A.
Rodriguez Cetina Biefer, H.
Dzemali, O.
author_facet Gruszczynski, M.
Müller-Burri, A.
Häussler, A.
Breitenstein, A.
Rodriguez Cetina Biefer, H.
Dzemali, O.
author_sort Gruszczynski, M.
collection PubMed
description Significant lead-induced tricuspid regurgitation after cardiovascular implantable electronic devices is not uncommon. Absolute or relative contraindications to place the lead in the right ventricle after tricuspid valve (TV) surgery still remains a challenge. We report about successful lead extraction followed by transvenous implantable cardioverter defibrillator lead placement in the side branches of coronary sinus after TV reconstruction. Furthermore, we discuss therapeutic options to deliver concomitant anti-bradycardia therapy, technical pitfalls, and surgical approaches.
format Online
Article
Text
id pubmed-9931479
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-99314792023-02-16 Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction Gruszczynski, M. Müller-Burri, A. Häussler, A. Breitenstein, A. Rodriguez Cetina Biefer, H. Dzemali, O. Case Rep Cardiol Case Report Significant lead-induced tricuspid regurgitation after cardiovascular implantable electronic devices is not uncommon. Absolute or relative contraindications to place the lead in the right ventricle after tricuspid valve (TV) surgery still remains a challenge. We report about successful lead extraction followed by transvenous implantable cardioverter defibrillator lead placement in the side branches of coronary sinus after TV reconstruction. Furthermore, we discuss therapeutic options to deliver concomitant anti-bradycardia therapy, technical pitfalls, and surgical approaches. Hindawi 2023-02-08 /pmc/articles/PMC9931479/ /pubmed/36819941 http://dx.doi.org/10.1155/2023/6646224 Text en Copyright © 2023 M. Gruszczynski et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Gruszczynski, M.
Müller-Burri, A.
Häussler, A.
Breitenstein, A.
Rodriguez Cetina Biefer, H.
Dzemali, O.
Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction
title Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction
title_full Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction
title_fullStr Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction
title_full_unstemmed Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction
title_short Transvenous ICD Implantation into a Coronary Sinus Branch: A Safe and Feasible Alternative to Deliver ICD after Tricuspid Valve Reconstruction
title_sort transvenous icd implantation into a coronary sinus branch: a safe and feasible alternative to deliver icd after tricuspid valve reconstruction
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931479/
https://www.ncbi.nlm.nih.gov/pubmed/36819941
http://dx.doi.org/10.1155/2023/6646224
work_keys_str_mv AT gruszczynskim transvenousicdimplantationintoacoronarysinusbranchasafeandfeasiblealternativetodelivericdaftertricuspidvalvereconstruction
AT mullerburria transvenousicdimplantationintoacoronarysinusbranchasafeandfeasiblealternativetodelivericdaftertricuspidvalvereconstruction
AT hausslera transvenousicdimplantationintoacoronarysinusbranchasafeandfeasiblealternativetodelivericdaftertricuspidvalvereconstruction
AT breitensteina transvenousicdimplantationintoacoronarysinusbranchasafeandfeasiblealternativetodelivericdaftertricuspidvalvereconstruction
AT rodriguezcetinabieferh transvenousicdimplantationintoacoronarysinusbranchasafeandfeasiblealternativetodelivericdaftertricuspidvalvereconstruction
AT dzemalio transvenousicdimplantationintoacoronarysinusbranchasafeandfeasiblealternativetodelivericdaftertricuspidvalvereconstruction