Cargando…
EANM practice guideline for quantitative SPECT-CT
PURPOSE: Quantitative SPECT-CT is a modality of growing importance with initial developments in post radionuclide therapy dosimetry, and more recent expansion into bone, cardiac and brain imaging together with the concept of theranostics more generally. The aim of this document is to provide guideli...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931838/ https://www.ncbi.nlm.nih.gov/pubmed/36469107 http://dx.doi.org/10.1007/s00259-022-06028-9 |
_version_ | 1784889321584590848 |
---|---|
author | Dickson, John C. Armstrong, Ian S. Gabiña, Pablo Minguez Denis-Bacelar, Ana M. Krizsan, Aron K. Gear, Jonathan M. Van den Wyngaert, Tim de Geus-Oei, Lioe-Fee Herrmann, Ken |
author_facet | Dickson, John C. Armstrong, Ian S. Gabiña, Pablo Minguez Denis-Bacelar, Ana M. Krizsan, Aron K. Gear, Jonathan M. Van den Wyngaert, Tim de Geus-Oei, Lioe-Fee Herrmann, Ken |
author_sort | Dickson, John C. |
collection | PubMed |
description | PURPOSE: Quantitative SPECT-CT is a modality of growing importance with initial developments in post radionuclide therapy dosimetry, and more recent expansion into bone, cardiac and brain imaging together with the concept of theranostics more generally. The aim of this document is to provide guidelines for nuclear medicine departments setting up and developing their quantitative SPECT-CT service with guidance on protocols, harmonisation and clinical use cases. METHODS: These practice guidelines were written by members of the European Association of Nuclear Medicine Physics, Dosimetry, Oncology and Bone committees representing the current major stakeholders in Quantitative SPECT-CT. The guidelines have also been reviewed and approved by all EANM committees and have been endorsed by the European Association of Nuclear Medicine. CONCLUSION: The present practice guidelines will help practitioners, scientists and researchers perform high-quality quantitative SPECT-CT and will provide a framework for the continuing development of quantitative SPECT-CT as an established modality. |
format | Online Article Text |
id | pubmed-9931838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-99318382023-02-17 EANM practice guideline for quantitative SPECT-CT Dickson, John C. Armstrong, Ian S. Gabiña, Pablo Minguez Denis-Bacelar, Ana M. Krizsan, Aron K. Gear, Jonathan M. Van den Wyngaert, Tim de Geus-Oei, Lioe-Fee Herrmann, Ken Eur J Nucl Med Mol Imaging Guidelines PURPOSE: Quantitative SPECT-CT is a modality of growing importance with initial developments in post radionuclide therapy dosimetry, and more recent expansion into bone, cardiac and brain imaging together with the concept of theranostics more generally. The aim of this document is to provide guidelines for nuclear medicine departments setting up and developing their quantitative SPECT-CT service with guidance on protocols, harmonisation and clinical use cases. METHODS: These practice guidelines were written by members of the European Association of Nuclear Medicine Physics, Dosimetry, Oncology and Bone committees representing the current major stakeholders in Quantitative SPECT-CT. The guidelines have also been reviewed and approved by all EANM committees and have been endorsed by the European Association of Nuclear Medicine. CONCLUSION: The present practice guidelines will help practitioners, scientists and researchers perform high-quality quantitative SPECT-CT and will provide a framework for the continuing development of quantitative SPECT-CT as an established modality. Springer Berlin Heidelberg 2022-12-05 2023 /pmc/articles/PMC9931838/ /pubmed/36469107 http://dx.doi.org/10.1007/s00259-022-06028-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Guidelines Dickson, John C. Armstrong, Ian S. Gabiña, Pablo Minguez Denis-Bacelar, Ana M. Krizsan, Aron K. Gear, Jonathan M. Van den Wyngaert, Tim de Geus-Oei, Lioe-Fee Herrmann, Ken EANM practice guideline for quantitative SPECT-CT |
title | EANM practice guideline for quantitative SPECT-CT |
title_full | EANM practice guideline for quantitative SPECT-CT |
title_fullStr | EANM practice guideline for quantitative SPECT-CT |
title_full_unstemmed | EANM practice guideline for quantitative SPECT-CT |
title_short | EANM practice guideline for quantitative SPECT-CT |
title_sort | eanm practice guideline for quantitative spect-ct |
topic | Guidelines |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931838/ https://www.ncbi.nlm.nih.gov/pubmed/36469107 http://dx.doi.org/10.1007/s00259-022-06028-9 |
work_keys_str_mv | AT dicksonjohnc eanmpracticeguidelineforquantitativespectct AT armstrongians eanmpracticeguidelineforquantitativespectct AT gabinapablominguez eanmpracticeguidelineforquantitativespectct AT denisbacelaranam eanmpracticeguidelineforquantitativespectct AT krizsanaronk eanmpracticeguidelineforquantitativespectct AT gearjonathanm eanmpracticeguidelineforquantitativespectct AT vandenwyngaerttim eanmpracticeguidelineforquantitativespectct AT degeusoeilioefee eanmpracticeguidelineforquantitativespectct AT herrmannken eanmpracticeguidelineforquantitativespectct |