Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation

BACKGROUND: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their...

Descripción completa

Detalles Bibliográficos
Autores principales: Roca-Luque, Ivo, Zaraket, Fatima, Garre, Paz, Sanchez-Somonte, Paula, Quinto, Levio, Borras, Roger, Guasch, Eduard, Arbelo, Elena, Tolosana, José Maria, Brugada, Josep, Mont, Lluís
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931851/
https://www.ncbi.nlm.nih.gov/pubmed/35195814
http://dx.doi.org/10.1007/s10840-022-01148-6
_version_ 1784889324395823104
author Roca-Luque, Ivo
Zaraket, Fatima
Garre, Paz
Sanchez-Somonte, Paula
Quinto, Levio
Borras, Roger
Guasch, Eduard
Arbelo, Elena
Tolosana, José Maria
Brugada, Josep
Mont, Lluís
author_facet Roca-Luque, Ivo
Zaraket, Fatima
Garre, Paz
Sanchez-Somonte, Paula
Quinto, Levio
Borras, Roger
Guasch, Eduard
Arbelo, Elena
Tolosana, José Maria
Brugada, Josep
Mont, Lluís
author_sort Roca-Luque, Ivo
collection PubMed
description BACKGROUND: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their abolition is the most accepted ablation endpoint. In the current guidelines, bipolar voltage thresholds for BZ and core scar are 1.5 and 0.5 mV respectively. The performance of these values is controversial. The aim of the study is to analyze the diagnostic yield of current amplitude thresholds in voltage map to define VT substrate in terms of CCs of LPs. Predictors of usefulness of current thresholds will be analyzed. METHODS: All patients with structural heart disease who underwent VT ablation in Hospital Clinic in 2016–2017 were included. Maps with delineation of CCs based on LPs were created with contact force sensor catheter. Thresholds were adjusted for every patient based on CCs. Diagnostic yield and predictors of performance of conventional thresholds were analyzed. RESULTS: During study period, 57 consecutive patients were included (age: 60.4 ± 8.5; 50.2% ischemic cardiomyopathy, LVEF 39.8 ± 13.5%). Cutoff voltages that better identified the scar and BZ according to the LP channels were 0.32 (0.02–2 mV) and 1.84 (0.3–6 mV) respectively. Current voltage thresholds identified correctly core and BZ in 87.7% and 42.1% of the patients respectively. Accuracy was worse in non-ischemic cardiomyopathy (NICM) especially for BZ (28.6% vs 55.2%, p = 0.042). CONCLUSIONS: Accuracy of standard voltage thresholds for scar and BZ is poor in terms of LPs detection. Diagnostic yield is worse in NICM patients specially for border zone.
format Online
Article
Text
id pubmed-9931851
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-99318512023-02-17 Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation Roca-Luque, Ivo Zaraket, Fatima Garre, Paz Sanchez-Somonte, Paula Quinto, Levio Borras, Roger Guasch, Eduard Arbelo, Elena Tolosana, José Maria Brugada, Josep Mont, Lluís J Interv Card Electrophysiol Article BACKGROUND: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their abolition is the most accepted ablation endpoint. In the current guidelines, bipolar voltage thresholds for BZ and core scar are 1.5 and 0.5 mV respectively. The performance of these values is controversial. The aim of the study is to analyze the diagnostic yield of current amplitude thresholds in voltage map to define VT substrate in terms of CCs of LPs. Predictors of usefulness of current thresholds will be analyzed. METHODS: All patients with structural heart disease who underwent VT ablation in Hospital Clinic in 2016–2017 were included. Maps with delineation of CCs based on LPs were created with contact force sensor catheter. Thresholds were adjusted for every patient based on CCs. Diagnostic yield and predictors of performance of conventional thresholds were analyzed. RESULTS: During study period, 57 consecutive patients were included (age: 60.4 ± 8.5; 50.2% ischemic cardiomyopathy, LVEF 39.8 ± 13.5%). Cutoff voltages that better identified the scar and BZ according to the LP channels were 0.32 (0.02–2 mV) and 1.84 (0.3–6 mV) respectively. Current voltage thresholds identified correctly core and BZ in 87.7% and 42.1% of the patients respectively. Accuracy was worse in non-ischemic cardiomyopathy (NICM) especially for BZ (28.6% vs 55.2%, p = 0.042). CONCLUSIONS: Accuracy of standard voltage thresholds for scar and BZ is poor in terms of LPs detection. Diagnostic yield is worse in NICM patients specially for border zone. Springer US 2022-02-23 2023 /pmc/articles/PMC9931851/ /pubmed/35195814 http://dx.doi.org/10.1007/s10840-022-01148-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Roca-Luque, Ivo
Zaraket, Fatima
Garre, Paz
Sanchez-Somonte, Paula
Quinto, Levio
Borras, Roger
Guasch, Eduard
Arbelo, Elena
Tolosana, José Maria
Brugada, Josep
Mont, Lluís
Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
title Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
title_full Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
title_fullStr Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
title_full_unstemmed Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
title_short Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
title_sort accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931851/
https://www.ncbi.nlm.nih.gov/pubmed/35195814
http://dx.doi.org/10.1007/s10840-022-01148-6
work_keys_str_mv AT rocaluqueivo accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT zaraketfatima accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT garrepaz accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT sanchezsomontepaula accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT quintolevio accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT borrasroger accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT guascheduard accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT arbeloelena accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT tolosanajosemaria accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT brugadajosep accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation
AT montlluis accuracyofstandardbipolaramplitudevoltagethresholdstoidentifylatepotentialchannelsinventriculartachycardiaablation