Cargando…

Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography

BACKGROUND: Premature ductus arteriosus constriction (DA Con) can result in right ventricular enlargement, right ventricular hypertrophy, and tricuspid regurgitation. METHOD: This study retrospectively analyzed 34 singleton fetuses that underwent fetal echocardiography with a diagnosis of DA Con (16...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Tianjing, Han, Jiancheng, Han, Yanli, Liu, Xiaowei, Gu, Xiaoyan, Zhang, Ye, Sun, Lin, Zhao, Ying, Gao, Shuang, Hao, Xiuxiu, He, Yihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9932508/
https://www.ncbi.nlm.nih.gov/pubmed/36816371
http://dx.doi.org/10.3389/fped.2023.1085352
_version_ 1784889467994112000
author Li, Tianjing
Han, Jiancheng
Han, Yanli
Liu, Xiaowei
Gu, Xiaoyan
Zhang, Ye
Sun, Lin
Zhao, Ying
Gao, Shuang
Hao, Xiuxiu
He, Yihua
author_facet Li, Tianjing
Han, Jiancheng
Han, Yanli
Liu, Xiaowei
Gu, Xiaoyan
Zhang, Ye
Sun, Lin
Zhao, Ying
Gao, Shuang
Hao, Xiuxiu
He, Yihua
author_sort Li, Tianjing
collection PubMed
description BACKGROUND: Premature ductus arteriosus constriction (DA Con) can result in right ventricular enlargement, right ventricular hypertrophy, and tricuspid regurgitation. METHOD: This study retrospectively analyzed 34 singleton fetuses that underwent fetal echocardiography with a diagnosis of DA Con (16 cases with mild to moderate, and 18 cases with moderate to severe) and 45 healthy fetuses. The morphology and function parameters of cardiac, as well as the 24-Segment of ventricles, were compared between the DA Con group and controls, and between the mild to moderate and moderate to severe groups, using the fetal heart quantification (FHQ) technology. RESULTS: There were no significant difference in left ventricular parameters in DA Con group when compared to controls. Moreover, fetal 4CV-GSI was significantly reduced, as well as the sphericity index (SI), fractional shortening (FS), global longitudinal strain (GS) and fractional area change (FAC) of right ventricle, especially in the basal-middle segments. Compared with the mild to moderate group, LV-FS increased and RV-FS decreased in moderate to severe group. CONCLUSION: The results showed that the fetal heart in the DA Con group was different from the controls in morphology and function. FHQ technology provides a comprehensive assessment for the evaluation of cardiac morphological and functional changes in DA Con fetuses.
format Online
Article
Text
id pubmed-9932508
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-99325082023-02-17 Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography Li, Tianjing Han, Jiancheng Han, Yanli Liu, Xiaowei Gu, Xiaoyan Zhang, Ye Sun, Lin Zhao, Ying Gao, Shuang Hao, Xiuxiu He, Yihua Front Pediatr Pediatrics BACKGROUND: Premature ductus arteriosus constriction (DA Con) can result in right ventricular enlargement, right ventricular hypertrophy, and tricuspid regurgitation. METHOD: This study retrospectively analyzed 34 singleton fetuses that underwent fetal echocardiography with a diagnosis of DA Con (16 cases with mild to moderate, and 18 cases with moderate to severe) and 45 healthy fetuses. The morphology and function parameters of cardiac, as well as the 24-Segment of ventricles, were compared between the DA Con group and controls, and between the mild to moderate and moderate to severe groups, using the fetal heart quantification (FHQ) technology. RESULTS: There were no significant difference in left ventricular parameters in DA Con group when compared to controls. Moreover, fetal 4CV-GSI was significantly reduced, as well as the sphericity index (SI), fractional shortening (FS), global longitudinal strain (GS) and fractional area change (FAC) of right ventricle, especially in the basal-middle segments. Compared with the mild to moderate group, LV-FS increased and RV-FS decreased in moderate to severe group. CONCLUSION: The results showed that the fetal heart in the DA Con group was different from the controls in morphology and function. FHQ technology provides a comprehensive assessment for the evaluation of cardiac morphological and functional changes in DA Con fetuses. Frontiers Media S.A. 2023-02-02 /pmc/articles/PMC9932508/ /pubmed/36816371 http://dx.doi.org/10.3389/fped.2023.1085352 Text en © 2023 Li, Han, Han, Liu, Gu, Zhang, Sun, Zhao, Gao, Hao and He. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Li, Tianjing
Han, Jiancheng
Han, Yanli
Liu, Xiaowei
Gu, Xiaoyan
Zhang, Ye
Sun, Lin
Zhao, Ying
Gao, Shuang
Hao, Xiuxiu
He, Yihua
Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography
title Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography
title_full Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography
title_fullStr Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography
title_full_unstemmed Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography
title_short Evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by Speckle-tracking echocardiography
title_sort evaluation of changes of cardiac morphology and function in fetuses with ductus arteriosus constriction by speckle-tracking echocardiography
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9932508/
https://www.ncbi.nlm.nih.gov/pubmed/36816371
http://dx.doi.org/10.3389/fped.2023.1085352
work_keys_str_mv AT litianjing evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT hanjiancheng evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT hanyanli evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT liuxiaowei evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT guxiaoyan evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT zhangye evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT sunlin evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT zhaoying evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT gaoshuang evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT haoxiuxiu evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography
AT heyihua evaluationofchangesofcardiacmorphologyandfunctioninfetuseswithductusarteriosusconstrictionbyspeckletrackingechocardiography