Cargando…
Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo
BACKGROUND: Although MRI is a radiation-free imaging modality, it has historically been limited in lung imaging due to inherent technical restrictions. The aim of this study is to explore the performance of lung MRI in detecting solid and subsolid pulmonary nodules using T1 gradient-echo (GRE) (VIBE...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933280/ https://www.ncbi.nlm.nih.gov/pubmed/36793094 http://dx.doi.org/10.1186/s40644-023-00531-4 |
_version_ | 1784889640238448640 |
---|---|
author | Sanchez, Felipe Tyrrell, Pascal N. Cheung, Patrick Heyn, Chinthaka Graham, Simon Poon, Ian Ung, Yee Louie, Alexander Tsao, May Oikonomou, Anastasia |
author_facet | Sanchez, Felipe Tyrrell, Pascal N. Cheung, Patrick Heyn, Chinthaka Graham, Simon Poon, Ian Ung, Yee Louie, Alexander Tsao, May Oikonomou, Anastasia |
author_sort | Sanchez, Felipe |
collection | PubMed |
description | BACKGROUND: Although MRI is a radiation-free imaging modality, it has historically been limited in lung imaging due to inherent technical restrictions. The aim of this study is to explore the performance of lung MRI in detecting solid and subsolid pulmonary nodules using T1 gradient-echo (GRE) (VIBE, Volumetric interpolated breath-hold examination), ultrashort time echo (UTE) and T2 Fast Spin Echo (HASTE, Half fourier Single-shot Turbo spin-Echo). METHODS: Patients underwent a lung MRI in a 3 T scanner as part of a prospective research project. A baseline Chest CT was obtained as part of their standard of care. Nodules were identified and measured on the baseline CT and categorized according to their density (solid and subsolid) and size (> 4 mm/ ≤ 4 mm). Nodules seen on the baseline CT were classified as present or absent on the different MRI sequences by two thoracic radiologists independently. Interobserver agreement was determined using the simple Kappa coefficient. Paired differences were compared using nonparametric Mann-Whitney U tests. The McNemar test was used to evaluate paired differences in nodule detection between MRI sequences. RESULTS: Thirty-six patients were prospectively enrolled. One hundred forty-nine nodules (100 solid/49 subsolid) with mean size 10.8 mm (SD = 9.4) were included in the analysis. There was substantial interobserver agreement (k = 0.7, p = 0.05). Detection for all nodules, solid and subsolid nodules was respectively; UTE: 71.8%/71.0%/73.5%; VIBE: 61.6%/65%/55.1%; HASTE 72.4%/72.2%/72.7%. Detection rate was higher for nodules > 4 mm in all groups: UTE 90.2%/93.4%/85.4%, VIBE 78.4%/88.5%/63.4%, HASTE 89.4%/93.8%/83.8%. Detection of lesions ≤4 mm was low for all sequences. UTE and HASTE performed significantly better than VIBE for detection of all nodules and subsolid nodules (diff = 18.4 and 17.6%, p = < 0.01 and p = 0.03, respectively). There was no significant difference between UTE and HASTE. There were no significant differences amongst MRI sequences for solid nodules. CONCLUSIONS: Lung MRI shows adequate performance for the detection of solid and subsolid pulmonary nodules larger than 4 mm and can serve as a promising radiation-free alternative to CT. |
format | Online Article Text |
id | pubmed-9933280 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99332802023-02-17 Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo Sanchez, Felipe Tyrrell, Pascal N. Cheung, Patrick Heyn, Chinthaka Graham, Simon Poon, Ian Ung, Yee Louie, Alexander Tsao, May Oikonomou, Anastasia Cancer Imaging Research Article BACKGROUND: Although MRI is a radiation-free imaging modality, it has historically been limited in lung imaging due to inherent technical restrictions. The aim of this study is to explore the performance of lung MRI in detecting solid and subsolid pulmonary nodules using T1 gradient-echo (GRE) (VIBE, Volumetric interpolated breath-hold examination), ultrashort time echo (UTE) and T2 Fast Spin Echo (HASTE, Half fourier Single-shot Turbo spin-Echo). METHODS: Patients underwent a lung MRI in a 3 T scanner as part of a prospective research project. A baseline Chest CT was obtained as part of their standard of care. Nodules were identified and measured on the baseline CT and categorized according to their density (solid and subsolid) and size (> 4 mm/ ≤ 4 mm). Nodules seen on the baseline CT were classified as present or absent on the different MRI sequences by two thoracic radiologists independently. Interobserver agreement was determined using the simple Kappa coefficient. Paired differences were compared using nonparametric Mann-Whitney U tests. The McNemar test was used to evaluate paired differences in nodule detection between MRI sequences. RESULTS: Thirty-six patients were prospectively enrolled. One hundred forty-nine nodules (100 solid/49 subsolid) with mean size 10.8 mm (SD = 9.4) were included in the analysis. There was substantial interobserver agreement (k = 0.7, p = 0.05). Detection for all nodules, solid and subsolid nodules was respectively; UTE: 71.8%/71.0%/73.5%; VIBE: 61.6%/65%/55.1%; HASTE 72.4%/72.2%/72.7%. Detection rate was higher for nodules > 4 mm in all groups: UTE 90.2%/93.4%/85.4%, VIBE 78.4%/88.5%/63.4%, HASTE 89.4%/93.8%/83.8%. Detection of lesions ≤4 mm was low for all sequences. UTE and HASTE performed significantly better than VIBE for detection of all nodules and subsolid nodules (diff = 18.4 and 17.6%, p = < 0.01 and p = 0.03, respectively). There was no significant difference between UTE and HASTE. There were no significant differences amongst MRI sequences for solid nodules. CONCLUSIONS: Lung MRI shows adequate performance for the detection of solid and subsolid pulmonary nodules larger than 4 mm and can serve as a promising radiation-free alternative to CT. BioMed Central 2023-02-16 /pmc/articles/PMC9933280/ /pubmed/36793094 http://dx.doi.org/10.1186/s40644-023-00531-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Sanchez, Felipe Tyrrell, Pascal N. Cheung, Patrick Heyn, Chinthaka Graham, Simon Poon, Ian Ung, Yee Louie, Alexander Tsao, May Oikonomou, Anastasia Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo |
title | Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo |
title_full | Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo |
title_fullStr | Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo |
title_full_unstemmed | Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo |
title_short | Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo |
title_sort | detection of solid and subsolid pulmonary nodules with lung mri: performance of ute, t1 gradient-echo, and single-shot t2 fast spin echo |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933280/ https://www.ncbi.nlm.nih.gov/pubmed/36793094 http://dx.doi.org/10.1186/s40644-023-00531-4 |
work_keys_str_mv | AT sanchezfelipe detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT tyrrellpascaln detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT cheungpatrick detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT heynchinthaka detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT grahamsimon detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT poonian detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT ungyee detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT louiealexander detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT tsaomay detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho AT oikonomouanastasia detectionofsolidandsubsolidpulmonarynoduleswithlungmriperformanceofutet1gradientechoandsingleshott2fastspinecho |