Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience

BACKGROUND: Cushing disease (CD) arises due to a pituitary corticotroph adenoma, which is the most common cause of Cushing syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) is a safe method for differentiating CD from ectopic adrenocorticotropic hormone (ACTH)-dependent CS. Enhanced...

Descripción completa

Detalles Bibliográficos
Autores principales: Mao, Jian-Nan, Yan, Hui-Ying, Chen, Jie-Yu, Yan, Chao-Long, Li, Ping, Jin, Wei, Hang, Chun-Hua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933337/
https://www.ncbi.nlm.nih.gov/pubmed/36793008
http://dx.doi.org/10.1186/s12902-023-01277-7
_version_ 1784889655350525952
author Mao, Jian-Nan
Yan, Hui-Ying
Chen, Jie-Yu
Yan, Chao-Long
Li, Ping
Jin, Wei
Hang, Chun-Hua
author_facet Mao, Jian-Nan
Yan, Hui-Ying
Chen, Jie-Yu
Yan, Chao-Long
Li, Ping
Jin, Wei
Hang, Chun-Hua
author_sort Mao, Jian-Nan
collection PubMed
description BACKGROUND: Cushing disease (CD) arises due to a pituitary corticotroph adenoma, which is the most common cause of Cushing syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) is a safe method for differentiating CD from ectopic adrenocorticotropic hormone (ACTH)-dependent CS. Enhanced high-resolution magnetic resonance imaging (MRI) can localize tiny pituitary lesions. The aim of this study was to compare the preoperative diagnostic accuracy of BIPSS versus MRI for CD in CS patients. We performed a retrospective study of patients who underwent BIPSS and MRI between 2017 and 2021. Low- and high-dose dexamethasone suppression tests were performed. Blood samples were collected simultaneously from the right and left catheter and femoral vein before and after desmopressin stimulation. MRI images were obtained, and endoscopic endonasal transsphenoidal surgery (EETS) was performed in confirmed CD patients. Dominant sides of ACTH secretion during BIPSS and MRI were compared with surgical findings. RESULTS: Twenty-nine patients underwent BIPSS and MRI. CD was diagnosed in 28 patients, 27 of whom received EETS. Localizations of microadenomas by MRI and BIPSS agreed with the EETS findings in 96% and 93% of the cases, respectively. BIPSS and EETS were successfully performed on all patients. CONCLUSION: BIPSS was the most accurate method (gold standard) for establishing a preoperative diagnosis of pituitary-dependent CD and was more sensitive than MRI in diagnosing microadenoma. High-resolution MRI with enhancement had an advantage over BIPSS in microadenoma lateralization diagnostics. The combined use of MRI and BIPSS could improve the preoperative diagnosis accuracy in ACTH-dependent CS patients.
format Online
Article
Text
id pubmed-9933337
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-99333372023-02-17 Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience Mao, Jian-Nan Yan, Hui-Ying Chen, Jie-Yu Yan, Chao-Long Li, Ping Jin, Wei Hang, Chun-Hua BMC Endocr Disord Research Article BACKGROUND: Cushing disease (CD) arises due to a pituitary corticotroph adenoma, which is the most common cause of Cushing syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) is a safe method for differentiating CD from ectopic adrenocorticotropic hormone (ACTH)-dependent CS. Enhanced high-resolution magnetic resonance imaging (MRI) can localize tiny pituitary lesions. The aim of this study was to compare the preoperative diagnostic accuracy of BIPSS versus MRI for CD in CS patients. We performed a retrospective study of patients who underwent BIPSS and MRI between 2017 and 2021. Low- and high-dose dexamethasone suppression tests were performed. Blood samples were collected simultaneously from the right and left catheter and femoral vein before and after desmopressin stimulation. MRI images were obtained, and endoscopic endonasal transsphenoidal surgery (EETS) was performed in confirmed CD patients. Dominant sides of ACTH secretion during BIPSS and MRI were compared with surgical findings. RESULTS: Twenty-nine patients underwent BIPSS and MRI. CD was diagnosed in 28 patients, 27 of whom received EETS. Localizations of microadenomas by MRI and BIPSS agreed with the EETS findings in 96% and 93% of the cases, respectively. BIPSS and EETS were successfully performed on all patients. CONCLUSION: BIPSS was the most accurate method (gold standard) for establishing a preoperative diagnosis of pituitary-dependent CD and was more sensitive than MRI in diagnosing microadenoma. High-resolution MRI with enhancement had an advantage over BIPSS in microadenoma lateralization diagnostics. The combined use of MRI and BIPSS could improve the preoperative diagnosis accuracy in ACTH-dependent CS patients. BioMed Central 2023-02-16 /pmc/articles/PMC9933337/ /pubmed/36793008 http://dx.doi.org/10.1186/s12902-023-01277-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Mao, Jian-Nan
Yan, Hui-Ying
Chen, Jie-Yu
Yan, Chao-Long
Li, Ping
Jin, Wei
Hang, Chun-Hua
Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience
title Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience
title_full Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience
title_fullStr Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience
title_full_unstemmed Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience
title_short Comparison of the preoperative diagnostic accuracy of BIPSS versus MRI for Cushing disease: a single-centre experience
title_sort comparison of the preoperative diagnostic accuracy of bipss versus mri for cushing disease: a single-centre experience
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933337/
https://www.ncbi.nlm.nih.gov/pubmed/36793008
http://dx.doi.org/10.1186/s12902-023-01277-7
work_keys_str_mv AT maojiannan comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience
AT yanhuiying comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience
AT chenjieyu comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience
AT yanchaolong comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience
AT liping comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience
AT jinwei comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience
AT hangchunhua comparisonofthepreoperativediagnosticaccuracyofbipssversusmriforcushingdiseaseasinglecentreexperience