Cargando…

Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal

[Image: see text] Low-cost air quality (LCAQ) sensors are increasingly being used for community air quality monitoring. However, data collected by low-cost sensors contain significant noise, and proper calibration of these sensors remains a widely discussed, but not yet fully addressed, area of conc...

Descripción completa

Detalles Bibliográficos
Autores principales: Hasan, Md Hasibul, Yu, Haofei, Ivey, Cesunica, Pillarisetti, Ajay, Yuan, Ziyang, Do, Khanh, Li, Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933490/
https://www.ncbi.nlm.nih.gov/pubmed/36816698
http://dx.doi.org/10.1021/acsomega.2c07734
_version_ 1784889689606455296
author Hasan, Md Hasibul
Yu, Haofei
Ivey, Cesunica
Pillarisetti, Ajay
Yuan, Ziyang
Do, Khanh
Li, Yi
author_facet Hasan, Md Hasibul
Yu, Haofei
Ivey, Cesunica
Pillarisetti, Ajay
Yuan, Ziyang
Do, Khanh
Li, Yi
author_sort Hasan, Md Hasibul
collection PubMed
description [Image: see text] Low-cost air quality (LCAQ) sensors are increasingly being used for community air quality monitoring. However, data collected by low-cost sensors contain significant noise, and proper calibration of these sensors remains a widely discussed, but not yet fully addressed, area of concern. In this study, several LCAQ sensors measuring nitrogen dioxide (NO(2)) and ozone (O(3)) were deployed in six cities in the United States (Atlanta, GA; New York City, NY; Sacramento, CA; Riverside, CA; Portland, OR; Phoenix, AZ) to evaluate the impacts of different climatic and geographical conditions on their performance and calibration. Three calibration methods were applied, including regression via linear and polynomial models and random forest methods. When signals from carbon monoxide (CO) sensors were included in the calibration models for NO(2) and O(3) sensors, model performance generally increased, with pronounced improvements in selected cities such as Riverside and New York City. Such improvements may be due to (1) temporal co-variation between concentrations of CO and NO(2) and/or between CO and O(3); (2) different performance levels of low-cost CO, NO(2), and O(3) sensors; and (3) different impacts of environmental conditions on sensor performance. The results showed an innovative approach for improving the calibration of NO(2) and O(3) sensors by including CO sensor signals into the calibration models. Community users of LCAQ sensors may be able to apply these findings further to enhance the data quality of their deployed NO(2) and O(3) monitors.
format Online
Article
Text
id pubmed-9933490
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-99334902023-02-17 Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal Hasan, Md Hasibul Yu, Haofei Ivey, Cesunica Pillarisetti, Ajay Yuan, Ziyang Do, Khanh Li, Yi ACS Omega [Image: see text] Low-cost air quality (LCAQ) sensors are increasingly being used for community air quality monitoring. However, data collected by low-cost sensors contain significant noise, and proper calibration of these sensors remains a widely discussed, but not yet fully addressed, area of concern. In this study, several LCAQ sensors measuring nitrogen dioxide (NO(2)) and ozone (O(3)) were deployed in six cities in the United States (Atlanta, GA; New York City, NY; Sacramento, CA; Riverside, CA; Portland, OR; Phoenix, AZ) to evaluate the impacts of different climatic and geographical conditions on their performance and calibration. Three calibration methods were applied, including regression via linear and polynomial models and random forest methods. When signals from carbon monoxide (CO) sensors were included in the calibration models for NO(2) and O(3) sensors, model performance generally increased, with pronounced improvements in selected cities such as Riverside and New York City. Such improvements may be due to (1) temporal co-variation between concentrations of CO and NO(2) and/or between CO and O(3); (2) different performance levels of low-cost CO, NO(2), and O(3) sensors; and (3) different impacts of environmental conditions on sensor performance. The results showed an innovative approach for improving the calibration of NO(2) and O(3) sensors by including CO sensor signals into the calibration models. Community users of LCAQ sensors may be able to apply these findings further to enhance the data quality of their deployed NO(2) and O(3) monitors. American Chemical Society 2023-01-31 /pmc/articles/PMC9933490/ /pubmed/36816698 http://dx.doi.org/10.1021/acsomega.2c07734 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Hasan, Md Hasibul
Yu, Haofei
Ivey, Cesunica
Pillarisetti, Ajay
Yuan, Ziyang
Do, Khanh
Li, Yi
Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
title Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
title_full Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
title_fullStr Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
title_full_unstemmed Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
title_short Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
title_sort unexpected performance improvements of nitrogen dioxide and ozone sensors by including carbon monoxide sensor signal
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933490/
https://www.ncbi.nlm.nih.gov/pubmed/36816698
http://dx.doi.org/10.1021/acsomega.2c07734
work_keys_str_mv AT hasanmdhasibul unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal
AT yuhaofei unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal
AT iveycesunica unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal
AT pillarisettiajay unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal
AT yuanziyang unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal
AT dokhanh unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal
AT liyi unexpectedperformanceimprovementsofnitrogendioxideandozonesensorsbyincludingcarbonmonoxidesensorsignal