Cargando…
Origins of Oil and Gas Sector Methane Emissions: On-Site Investigations of Aerial Measured Sources
[Image: see text] Success in reducing oil and gas sector methane emissions is contingent on understanding the sources driving emissions, associated options for mitigation, and the effectiveness of regulations in achieving intended outcomes. This study combines high-resolution, high-sensitivity aeria...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933527/ https://www.ncbi.nlm.nih.gov/pubmed/36716186 http://dx.doi.org/10.1021/acs.est.2c07318 |
_version_ | 1784889698808758272 |
---|---|
author | Johnson, Matthew R. Tyner, David R. Conrad, Bradley M. |
author_facet | Johnson, Matthew R. Tyner, David R. Conrad, Bradley M. |
author_sort | Johnson, Matthew R. |
collection | PubMed |
description | [Image: see text] Success in reducing oil and gas sector methane emissions is contingent on understanding the sources driving emissions, associated options for mitigation, and the effectiveness of regulations in achieving intended outcomes. This study combines high-resolution, high-sensitivity aerial survey data with subsequent on-site investigations of detected sources to examine these points. Measurements were performed in British Columbia, Canada, an active oil- and gas-producing province with modern methane regulations featuring mandatory three times per year leak detection and repair (LDAR) surveys at most facilities. Derived emission factors enabled by source attribution show that significant methane emissions persist under this regulatory framework, dominated by (i) combustion slip (compressor exhaust and also catalytic heaters, which are not covered in current regulations), (ii) intentional venting (uncontrolled tanks, vent stacks or intentionally unlit flares, and uncontrolled compressors), and (iii) unintentional venting (controlled tanks, unintentionally unlit/blown out flares, and abnormally operating pneumatics). Although the detailed analysis shows mitigation options exist for all sources, the importance of combustion slip and the persistently large methane contributions from controlled tanks and unlit flares demonstrate the limits of current LDAR programs and the critical need for additional monitoring and verification if regulations are to have the intended impacts, and reduction targets of 75% and greater are to be met. |
format | Online Article Text |
id | pubmed-9933527 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-99335272023-02-17 Origins of Oil and Gas Sector Methane Emissions: On-Site Investigations of Aerial Measured Sources Johnson, Matthew R. Tyner, David R. Conrad, Bradley M. Environ Sci Technol [Image: see text] Success in reducing oil and gas sector methane emissions is contingent on understanding the sources driving emissions, associated options for mitigation, and the effectiveness of regulations in achieving intended outcomes. This study combines high-resolution, high-sensitivity aerial survey data with subsequent on-site investigations of detected sources to examine these points. Measurements were performed in British Columbia, Canada, an active oil- and gas-producing province with modern methane regulations featuring mandatory three times per year leak detection and repair (LDAR) surveys at most facilities. Derived emission factors enabled by source attribution show that significant methane emissions persist under this regulatory framework, dominated by (i) combustion slip (compressor exhaust and also catalytic heaters, which are not covered in current regulations), (ii) intentional venting (uncontrolled tanks, vent stacks or intentionally unlit flares, and uncontrolled compressors), and (iii) unintentional venting (controlled tanks, unintentionally unlit/blown out flares, and abnormally operating pneumatics). Although the detailed analysis shows mitigation options exist for all sources, the importance of combustion slip and the persistently large methane contributions from controlled tanks and unlit flares demonstrate the limits of current LDAR programs and the critical need for additional monitoring and verification if regulations are to have the intended impacts, and reduction targets of 75% and greater are to be met. American Chemical Society 2023-01-30 /pmc/articles/PMC9933527/ /pubmed/36716186 http://dx.doi.org/10.1021/acs.est.2c07318 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Johnson, Matthew R. Tyner, David R. Conrad, Bradley M. Origins of Oil and Gas Sector Methane Emissions: On-Site Investigations of Aerial Measured Sources |
title | Origins
of Oil and Gas Sector Methane Emissions: On-Site
Investigations of Aerial Measured Sources |
title_full | Origins
of Oil and Gas Sector Methane Emissions: On-Site
Investigations of Aerial Measured Sources |
title_fullStr | Origins
of Oil and Gas Sector Methane Emissions: On-Site
Investigations of Aerial Measured Sources |
title_full_unstemmed | Origins
of Oil and Gas Sector Methane Emissions: On-Site
Investigations of Aerial Measured Sources |
title_short | Origins
of Oil and Gas Sector Methane Emissions: On-Site
Investigations of Aerial Measured Sources |
title_sort | origins
of oil and gas sector methane emissions: on-site
investigations of aerial measured sources |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933527/ https://www.ncbi.nlm.nih.gov/pubmed/36716186 http://dx.doi.org/10.1021/acs.est.2c07318 |
work_keys_str_mv | AT johnsonmatthewr originsofoilandgassectormethaneemissionsonsiteinvestigationsofaerialmeasuredsources AT tynerdavidr originsofoilandgassectormethaneemissionsonsiteinvestigationsofaerialmeasuredsources AT conradbradleym originsofoilandgassectormethaneemissionsonsiteinvestigationsofaerialmeasuredsources |