Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function

BACKGROUND: Low back pain is the leading cause of disability worldwide. Subjective assessments are often used to assess extent of functional limitations and treatment response. However, these measures have poor sensitivity and are influenced by the patient’s perception of their condition. Currently,...

Descripción completa

Detalles Bibliográficos
Autores principales: Hani, Hamed, Souchereau, Reid, Kachlan, Anas, Harris, Halle, Dufour, Jonathan, Aurand, Alexander, Mageswaran, Prasath, Hyer, Madison, Marras, William
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9934370/
https://www.ncbi.nlm.nih.gov/pubmed/36816092
http://dx.doi.org/10.31031/acam.2022.07.000660
_version_ 1784889870075822080
author Hani, Hamed
Souchereau, Reid
Kachlan, Anas
Harris, Halle
Dufour, Jonathan
Aurand, Alexander
Mageswaran, Prasath
Hyer, Madison
Marras, William
author_facet Hani, Hamed
Souchereau, Reid
Kachlan, Anas
Harris, Halle
Dufour, Jonathan
Aurand, Alexander
Mageswaran, Prasath
Hyer, Madison
Marras, William
author_sort Hani, Hamed
collection PubMed
description BACKGROUND: Low back pain is the leading cause of disability worldwide. Subjective assessments are often used to assess extent of functional limitations and treatment response. However, these measures have poor sensitivity and are influenced by the patient’s perception of their condition. Currently, there are no objective tools to effectively assess the extent of an individual’s functional disability and inform clinical decision-making. OBJECTIVE: The purpose of this study was to evaluate the reliability of a wearable motion system based on Inertial Measurement Unit (IMU) sensors for use in quantifying low back function. METHODS: Low back motion assessments were conducted by 3 novice raters on 20 participants using an IMU-based motion system. These assessments were conducted over 3 days with 2 days of rest in between tests. A total of 37 kinematic parameters were extracted from the low back motion assessment in all three anatomical planes. Intra-rater and inter-rater reliability were assessed using Intraclass Correlation Coefficients (ICCs) calculated from repeated measures, mixed-effects regression models. RESULTS: Lumbar spine-specific kinematic parameters showed moderate to excellent reliability across all kinematic parameters. The ICC values ranged between 0.84–0.93 for intra-rater reliability and 0.66 – 0.83 for inter-rater reliability. In particular, velocity measures showed higher reliabilities than other kinematic variables. CONCLUSION: The IMU-based wearable motion system is a valid and reliable tool to objectively assess low back function. This study demonstrated that lumbar spine-specific kinematic metrics have the potential to provide good, repeatable metrics to assess clinical function over time.
format Online
Article
Text
id pubmed-9934370
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-99343702023-02-16 Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function Hani, Hamed Souchereau, Reid Kachlan, Anas Harris, Halle Dufour, Jonathan Aurand, Alexander Mageswaran, Prasath Hyer, Madison Marras, William Adv Complement Altern Med Article BACKGROUND: Low back pain is the leading cause of disability worldwide. Subjective assessments are often used to assess extent of functional limitations and treatment response. However, these measures have poor sensitivity and are influenced by the patient’s perception of their condition. Currently, there are no objective tools to effectively assess the extent of an individual’s functional disability and inform clinical decision-making. OBJECTIVE: The purpose of this study was to evaluate the reliability of a wearable motion system based on Inertial Measurement Unit (IMU) sensors for use in quantifying low back function. METHODS: Low back motion assessments were conducted by 3 novice raters on 20 participants using an IMU-based motion system. These assessments were conducted over 3 days with 2 days of rest in between tests. A total of 37 kinematic parameters were extracted from the low back motion assessment in all three anatomical planes. Intra-rater and inter-rater reliability were assessed using Intraclass Correlation Coefficients (ICCs) calculated from repeated measures, mixed-effects regression models. RESULTS: Lumbar spine-specific kinematic parameters showed moderate to excellent reliability across all kinematic parameters. The ICC values ranged between 0.84–0.93 for intra-rater reliability and 0.66 – 0.83 for inter-rater reliability. In particular, velocity measures showed higher reliabilities than other kinematic variables. CONCLUSION: The IMU-based wearable motion system is a valid and reliable tool to objectively assess low back function. This study demonstrated that lumbar spine-specific kinematic metrics have the potential to provide good, repeatable metrics to assess clinical function over time. 2022 2022-07-06 /pmc/articles/PMC9934370/ /pubmed/36816092 http://dx.doi.org/10.31031/acam.2022.07.000660 Text en https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 International License, which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Article
Hani, Hamed
Souchereau, Reid
Kachlan, Anas
Harris, Halle
Dufour, Jonathan
Aurand, Alexander
Mageswaran, Prasath
Hyer, Madison
Marras, William
Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function
title Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function
title_full Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function
title_fullStr Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function
title_full_unstemmed Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function
title_short Reliability of a Wearable Motion System for Clinical Evaluation of Dynamic Lumbar Spine Function
title_sort reliability of a wearable motion system for clinical evaluation of dynamic lumbar spine function
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9934370/
https://www.ncbi.nlm.nih.gov/pubmed/36816092
http://dx.doi.org/10.31031/acam.2022.07.000660
work_keys_str_mv AT hanihamed reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT souchereaureid reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT kachlananas reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT harrishalle reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT dufourjonathan reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT aurandalexander reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT mageswaranprasath reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT hyermadison reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction
AT marraswilliam reliabilityofawearablemotionsystemforclinicalevaluationofdynamiclumbarspinefunction