Cargando…

8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla

The quality of cervical spinal cord images can be improved by the use of tailored radiofrequency coil solutions for ultra-high field imaging; however, very few commercial and research 7 Tesla radiofrequency coils currently exist for the spinal cord, and in particular those with parallel transmit cap...

Descripción completa

Detalles Bibliográficos
Autores principales: Rios, Nibardo Lopez, Gilbert, Kyle M., Papp, Daniel, Cereza, Gaspard, Foias, Alexandru, Rangaprakash, D., May, Markus W., Guerin, Bastien, Wald, Lawrence L., Keil, Boris, Stockmann, Jason P., Barry, Robert L., Cohen-Adad, Julien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cold Spring Harbor Laboratory 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9934596/
https://www.ncbi.nlm.nih.gov/pubmed/36798276
http://dx.doi.org/10.1101/2023.02.08.527664
_version_ 1784889916601139200
author Rios, Nibardo Lopez
Gilbert, Kyle M.
Papp, Daniel
Cereza, Gaspard
Foias, Alexandru
Rangaprakash, D.
May, Markus W.
Guerin, Bastien
Wald, Lawrence L.
Keil, Boris
Stockmann, Jason P.
Barry, Robert L.
Cohen-Adad, Julien
author_facet Rios, Nibardo Lopez
Gilbert, Kyle M.
Papp, Daniel
Cereza, Gaspard
Foias, Alexandru
Rangaprakash, D.
May, Markus W.
Guerin, Bastien
Wald, Lawrence L.
Keil, Boris
Stockmann, Jason P.
Barry, Robert L.
Cohen-Adad, Julien
author_sort Rios, Nibardo Lopez
collection PubMed
description The quality of cervical spinal cord images can be improved by the use of tailored radiofrequency coil solutions for ultra-high field imaging; however, very few commercial and research 7 Tesla radiofrequency coils currently exist for the spinal cord, and in particular those with parallel transmit capabilities. This work presents the design, testing and validation of a pTx/Rx coil for the human neck and cervical/upper-thoracic spinal cord. The pTx portion is composed of 8 dipoles to ensure high homogeneity over this large region of the spinal cord. The Rx portion is made of 20 semi-adaptable overlapping loops to produce high Signal-to-noise ratio (SNR) across the patient population. The coil housing is designed to facilitate patient positioning and comfort, while being tight fitting to ensure high sensitivity. We demonstrate RF shimming capabilities to optimize B(1)(+) uniformity, power efficiency and/or specific absorption rate (SAR) efficiency. B(1)(+) homogeneity, SNR and g-factor was evaluated in adult volunteers and demonstrated excellent performance from the occipital lobe down to the T4-T5 level. We compared the proposed coil with two state-of-the-art head and head/neck coils, confirming its superiority in the cervical and upper-thoracic regions of the spinal cord. This coil solution therefore provides a convincing platform for producing the high image quality necessary for clinical and research scanning of the upper spinal cord.
format Online
Article
Text
id pubmed-9934596
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cold Spring Harbor Laboratory
record_format MEDLINE/PubMed
spelling pubmed-99345962023-02-17 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla Rios, Nibardo Lopez Gilbert, Kyle M. Papp, Daniel Cereza, Gaspard Foias, Alexandru Rangaprakash, D. May, Markus W. Guerin, Bastien Wald, Lawrence L. Keil, Boris Stockmann, Jason P. Barry, Robert L. Cohen-Adad, Julien bioRxiv Article The quality of cervical spinal cord images can be improved by the use of tailored radiofrequency coil solutions for ultra-high field imaging; however, very few commercial and research 7 Tesla radiofrequency coils currently exist for the spinal cord, and in particular those with parallel transmit capabilities. This work presents the design, testing and validation of a pTx/Rx coil for the human neck and cervical/upper-thoracic spinal cord. The pTx portion is composed of 8 dipoles to ensure high homogeneity over this large region of the spinal cord. The Rx portion is made of 20 semi-adaptable overlapping loops to produce high Signal-to-noise ratio (SNR) across the patient population. The coil housing is designed to facilitate patient positioning and comfort, while being tight fitting to ensure high sensitivity. We demonstrate RF shimming capabilities to optimize B(1)(+) uniformity, power efficiency and/or specific absorption rate (SAR) efficiency. B(1)(+) homogeneity, SNR and g-factor was evaluated in adult volunteers and demonstrated excellent performance from the occipital lobe down to the T4-T5 level. We compared the proposed coil with two state-of-the-art head and head/neck coils, confirming its superiority in the cervical and upper-thoracic regions of the spinal cord. This coil solution therefore provides a convincing platform for producing the high image quality necessary for clinical and research scanning of the upper spinal cord. Cold Spring Harbor Laboratory 2023-02-09 /pmc/articles/PMC9934596/ /pubmed/36798276 http://dx.doi.org/10.1101/2023.02.08.527664 Text en https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/) , which allows reusers to distribute, remix, adapt, and build upon the material in any medium or format for noncommercial purposes only, and only so long as attribution is given to the creator.
spellingShingle Article
Rios, Nibardo Lopez
Gilbert, Kyle M.
Papp, Daniel
Cereza, Gaspard
Foias, Alexandru
Rangaprakash, D.
May, Markus W.
Guerin, Bastien
Wald, Lawrence L.
Keil, Boris
Stockmann, Jason P.
Barry, Robert L.
Cohen-Adad, Julien
8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
title 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
title_full 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
title_fullStr 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
title_full_unstemmed 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
title_short 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
title_sort 8-channel tx dipole and 20-channel rx loop coil array for mri of the cervical spinal cord at 7 tesla
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9934596/
https://www.ncbi.nlm.nih.gov/pubmed/36798276
http://dx.doi.org/10.1101/2023.02.08.527664
work_keys_str_mv AT riosnibardolopez 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT gilbertkylem 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT pappdaniel 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT cerezagaspard 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT foiasalexandru 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT rangaprakashd 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT maymarkusw 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT guerinbastien 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT waldlawrencel 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT keilboris 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT stockmannjasonp 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT barryrobertl 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla
AT cohenadadjulien 8channeltxdipoleand20channelrxloopcoilarrayformriofthecervicalspinalcordat7tesla