Iatrogenic Injury to Profunda Femoris During a Dynamic Hip Screw Fixation for Intertrochanteric Fracture

We present a case of a profunda femoris artery injury during a dynamic hip screw fixation for an intertrochanteric fracture. This was identified clinically on the ward and confirmed with a CT angiogram. The bleeder was then treated by coil embolization, and laboratory results showed significant impr...

Descripción completa

Detalles Bibliográficos
Autores principales: Lal, Anuj, Jesudason, Edwin, Gwyn, Rhodri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9934907/
https://www.ncbi.nlm.nih.gov/pubmed/36819373
http://dx.doi.org/10.7759/cureus.33894