Cargando…

Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration

OBJECTIVE: To investigate the confounding effect of nonexudative age-related macular degeneration (AMD), specifically drusen and outer retinal atrophy, on the architecture and automated segmentation of the inner retinal layers as measured with OCT. DESIGN: Observational cross-sectional study. SUBJEC...

Descripción completa

Detalles Bibliográficos
Autores principales: Chew, Leila, Mohammadzadeh, Vahid, Mohammadi, Massood, Toriz, Veronica, Rosa, Nancy, Gorin, Michael B., Amini, Navid, Nouri-Mahdavi, Kouros
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9937646/
https://www.ncbi.nlm.nih.gov/pubmed/35750324
http://dx.doi.org/10.1016/j.ogla.2022.06.006
_version_ 1784890468197203968
author Chew, Leila
Mohammadzadeh, Vahid
Mohammadi, Massood
Toriz, Veronica
Rosa, Nancy
Gorin, Michael B.
Amini, Navid
Nouri-Mahdavi, Kouros
author_facet Chew, Leila
Mohammadzadeh, Vahid
Mohammadi, Massood
Toriz, Veronica
Rosa, Nancy
Gorin, Michael B.
Amini, Navid
Nouri-Mahdavi, Kouros
author_sort Chew, Leila
collection PubMed
description OBJECTIVE: To investigate the confounding effect of nonexudative age-related macular degeneration (AMD), specifically drusen and outer retinal atrophy, on the architecture and automated segmentation of the inner retinal layers as measured with OCT. DESIGN: Observational cross-sectional study. SUBJECTS: Two hundred sixty-three consecutive eyes with nonexudative AMD were identified through a retrospective chart review. Exclusion criteria were a diagnosis of glaucoma or glaucoma suspect, other retinal pathology affecting the macula, axial length > 26.5 mm or spherical equivalent less than −6 diopters, any other optic nerve or neurologic disorders, or poor image quality. METHODS: Drusen were automatically segmented on macular OCT B-scans with a publicly available and validated deep learning approach. Automated segmentation of the inner plexiform layer (IPL)/inner nuclear layer (INL) boundary was carried out with the device’s proprietary software. MAIN OUTCOME MEASURES: Quality of segmentation of the IPL/INL boundary as a function of drusen size and presence of inner retinal layer displacement in the area of macular pathology (drusen or atrophy). RESULTS: One hundred twenty-five eyes (65 patients) met the inclusion criteria. Drusen size varied between 16 and 272 μm (mean, 118 μm). Automated segmentation had a 22% chance of failure if the drusen height was between 145 and 185 μm and was most likely to fail with drusen heights above 185 μm. When drusen height was normalized by total retinal thickness, segmentation failed 36% of the time when the drusen to total retinal thickness ratio was 0.45 or above. Images were likely to show displacement of inner retinal layers with drusen heights above 176 μm and a normalized drusen height ratio of 0.5 or higher. Eighty-seven percent of images with outer retinal atrophy displayed incorrect segmentation. CONCLUSIONS: Outer retinal diseases can alter the retinal topography and affect the segmentation accuracy of the inner retinal layers. Large drusen may cause segmentation error and compression of the inner macular layers. Geographic atrophy confounds automated segmentation in a high proportion of eyes. Clinicians should be cognizant of the effects of outer retinal disease on the inner retinal layer measurements when interpreting the results of macular OCT imaging in patients with glaucoma.
format Online
Article
Text
id pubmed-9937646
institution National Center for Biotechnology Information
language English
publishDate 2023
record_format MEDLINE/PubMed
spelling pubmed-99376462023-02-17 Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration Chew, Leila Mohammadzadeh, Vahid Mohammadi, Massood Toriz, Veronica Rosa, Nancy Gorin, Michael B. Amini, Navid Nouri-Mahdavi, Kouros Ophthalmol Glaucoma Article OBJECTIVE: To investigate the confounding effect of nonexudative age-related macular degeneration (AMD), specifically drusen and outer retinal atrophy, on the architecture and automated segmentation of the inner retinal layers as measured with OCT. DESIGN: Observational cross-sectional study. SUBJECTS: Two hundred sixty-three consecutive eyes with nonexudative AMD were identified through a retrospective chart review. Exclusion criteria were a diagnosis of glaucoma or glaucoma suspect, other retinal pathology affecting the macula, axial length > 26.5 mm or spherical equivalent less than −6 diopters, any other optic nerve or neurologic disorders, or poor image quality. METHODS: Drusen were automatically segmented on macular OCT B-scans with a publicly available and validated deep learning approach. Automated segmentation of the inner plexiform layer (IPL)/inner nuclear layer (INL) boundary was carried out with the device’s proprietary software. MAIN OUTCOME MEASURES: Quality of segmentation of the IPL/INL boundary as a function of drusen size and presence of inner retinal layer displacement in the area of macular pathology (drusen or atrophy). RESULTS: One hundred twenty-five eyes (65 patients) met the inclusion criteria. Drusen size varied between 16 and 272 μm (mean, 118 μm). Automated segmentation had a 22% chance of failure if the drusen height was between 145 and 185 μm and was most likely to fail with drusen heights above 185 μm. When drusen height was normalized by total retinal thickness, segmentation failed 36% of the time when the drusen to total retinal thickness ratio was 0.45 or above. Images were likely to show displacement of inner retinal layers with drusen heights above 176 μm and a normalized drusen height ratio of 0.5 or higher. Eighty-seven percent of images with outer retinal atrophy displayed incorrect segmentation. CONCLUSIONS: Outer retinal diseases can alter the retinal topography and affect the segmentation accuracy of the inner retinal layers. Large drusen may cause segmentation error and compression of the inner macular layers. Geographic atrophy confounds automated segmentation in a high proportion of eyes. Clinicians should be cognizant of the effects of outer retinal disease on the inner retinal layer measurements when interpreting the results of macular OCT imaging in patients with glaucoma. 2023 2022-06-21 /pmc/articles/PMC9937646/ /pubmed/35750324 http://dx.doi.org/10.1016/j.ogla.2022.06.006 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Chew, Leila
Mohammadzadeh, Vahid
Mohammadi, Massood
Toriz, Veronica
Rosa, Nancy
Gorin, Michael B.
Amini, Navid
Nouri-Mahdavi, Kouros
Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration
title Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration
title_full Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration
title_fullStr Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration
title_full_unstemmed Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration
title_short Measurement of the Inner Macular Layers for Monitoring of Glaucoma: Confounding Effects of Age-Related Macular Degeneration
title_sort measurement of the inner macular layers for monitoring of glaucoma: confounding effects of age-related macular degeneration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9937646/
https://www.ncbi.nlm.nih.gov/pubmed/35750324
http://dx.doi.org/10.1016/j.ogla.2022.06.006
work_keys_str_mv AT chewleila measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT mohammadzadehvahid measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT mohammadimassood measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT torizveronica measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT rosanancy measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT gorinmichaelb measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT amininavid measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration
AT nourimahdavikouros measurementoftheinnermacularlayersformonitoringofglaucomaconfoundingeffectsofagerelatedmaculardegeneration