Cargando…
Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid()
BACKGROUND: Tranexamic acid (TXA) is widely used in hip and knee arthroplasty to reduce perioperative bleeding. Recently, its use has been expanded to arthroscopic surgery. The purpose of this study was to evaluate the efficacy of preoperative use of TXA in arthroscopic rotator cuff repair (RCR). ME...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Asia-Pacific Knee, Arthroscopy and Sports Medicine Society
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9937805/ https://www.ncbi.nlm.nih.gov/pubmed/36820053 http://dx.doi.org/10.1016/j.asmart.2023.01.001 |
_version_ | 1784890504352104448 |
---|---|
author | Kawaguchi, Shinji Fukuta, Shoji Kano, Masashi Sairyo, Koichi |
author_facet | Kawaguchi, Shinji Fukuta, Shoji Kano, Masashi Sairyo, Koichi |
author_sort | Kawaguchi, Shinji |
collection | PubMed |
description | BACKGROUND: Tranexamic acid (TXA) is widely used in hip and knee arthroplasty to reduce perioperative bleeding. Recently, its use has been expanded to arthroscopic surgery. The purpose of this study was to evaluate the efficacy of preoperative use of TXA in arthroscopic rotator cuff repair (RCR). METHODS: A cohort comprising 129 consecutive patients who underwent arthroscopic primary RCR at our institution was retrospectively investigated according to whether they received TXA (April 2018 to December 2020, TXA group, n = 64) or did not receive TXA (April 2016 to March 2018, non-TXA group, n = 65). TXA was administered at a dose of 1 g intravenously. Rotator cuff tears were repaired by the suture bridge technique. Videos of the arthroscopic procedures were reviewed and rated for visual clarity using a 10-point numeric rating scale. Arthroscopic procedures were divided into glenohumeral, resection of bursal tissue and acromioplasty, and RCR steps. Each step was rated separately. Age, sex, body mass index, hemoglobin level before and on days 1 and 7 after surgery, operating time, mean arterial pressure, tear size, and number of anchors used for cuff repair were compared between the two groups. RESULTS: There were no statistically significant differences in the patient demographic data. The operating time was significantly shorter in the TXA group than in non-TXA group (97.8 ± 21.8 min vs 116.2 ± 26.0 min). The clarity of the visual field was similar between the two groups during the glenohumeral phase but was significantly higher in the TXA group during the resection of bursal tissue and acromioplasty and RCR phases. Hemoglobin level was not significantly different between the groups on postoperative day 1 but was significantly higher in the TXA group on day 7. CONCLUSION: Administration of a single intravenous dose of TXA improved visual clarity in arthroscopic RCR, decreased the total operating time, and reduced hemoglobin loss on postoperative day 7. |
format | Online Article Text |
id | pubmed-9937805 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Asia-Pacific Knee, Arthroscopy and Sports Medicine Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-99378052023-02-19 Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() Kawaguchi, Shinji Fukuta, Shoji Kano, Masashi Sairyo, Koichi Asia Pac J Sports Med Arthrosc Rehabil Technol Original Article BACKGROUND: Tranexamic acid (TXA) is widely used in hip and knee arthroplasty to reduce perioperative bleeding. Recently, its use has been expanded to arthroscopic surgery. The purpose of this study was to evaluate the efficacy of preoperative use of TXA in arthroscopic rotator cuff repair (RCR). METHODS: A cohort comprising 129 consecutive patients who underwent arthroscopic primary RCR at our institution was retrospectively investigated according to whether they received TXA (April 2018 to December 2020, TXA group, n = 64) or did not receive TXA (April 2016 to March 2018, non-TXA group, n = 65). TXA was administered at a dose of 1 g intravenously. Rotator cuff tears were repaired by the suture bridge technique. Videos of the arthroscopic procedures were reviewed and rated for visual clarity using a 10-point numeric rating scale. Arthroscopic procedures were divided into glenohumeral, resection of bursal tissue and acromioplasty, and RCR steps. Each step was rated separately. Age, sex, body mass index, hemoglobin level before and on days 1 and 7 after surgery, operating time, mean arterial pressure, tear size, and number of anchors used for cuff repair were compared between the two groups. RESULTS: There were no statistically significant differences in the patient demographic data. The operating time was significantly shorter in the TXA group than in non-TXA group (97.8 ± 21.8 min vs 116.2 ± 26.0 min). The clarity of the visual field was similar between the two groups during the glenohumeral phase but was significantly higher in the TXA group during the resection of bursal tissue and acromioplasty and RCR phases. Hemoglobin level was not significantly different between the groups on postoperative day 1 but was significantly higher in the TXA group on day 7. CONCLUSION: Administration of a single intravenous dose of TXA improved visual clarity in arthroscopic RCR, decreased the total operating time, and reduced hemoglobin loss on postoperative day 7. Asia-Pacific Knee, Arthroscopy and Sports Medicine Society 2023-02-07 /pmc/articles/PMC9937805/ /pubmed/36820053 http://dx.doi.org/10.1016/j.asmart.2023.01.001 Text en © 2023 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier (Singapore) Pte Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Kawaguchi, Shinji Fukuta, Shoji Kano, Masashi Sairyo, Koichi Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
title | Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
title_full | Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
title_fullStr | Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
title_full_unstemmed | Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
title_short | Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
title_sort | reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid() |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9937805/ https://www.ncbi.nlm.nih.gov/pubmed/36820053 http://dx.doi.org/10.1016/j.asmart.2023.01.001 |
work_keys_str_mv | AT kawaguchishinji reductionofperioperativebloodlossandoperatingtimeforarthroscopicrotatorcuffrepairbyintravenousadministrationoftranexamicacid AT fukutashoji reductionofperioperativebloodlossandoperatingtimeforarthroscopicrotatorcuffrepairbyintravenousadministrationoftranexamicacid AT kanomasashi reductionofperioperativebloodlossandoperatingtimeforarthroscopicrotatorcuffrepairbyintravenousadministrationoftranexamicacid AT sairyokoichi reductionofperioperativebloodlossandoperatingtimeforarthroscopicrotatorcuffrepairbyintravenousadministrationoftranexamicacid |