Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology

AIM OF THE STUDY: Although defibrillation using automated external defibrillator (AED) by bystander prior to emergency medical system (EMS) arrival was associated with favorable outcomes in out-of-hospital cardiac arrest (OHCA) of cardiac cause, whether it improves outcomes of OHCA due to non-cardia...

Descripción completa

Detalles Bibliográficos
Autores principales: Komori, Akira, Iriyama, Hiroki, Abe, Toshikazu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9939706/
https://www.ncbi.nlm.nih.gov/pubmed/36814461
http://dx.doi.org/10.1016/j.resplu.2023.100363
_version_ 1784890916784308224
author Komori, Akira
Iriyama, Hiroki
Abe, Toshikazu
author_facet Komori, Akira
Iriyama, Hiroki
Abe, Toshikazu
author_sort Komori, Akira
collection PubMed
description AIM OF THE STUDY: Although defibrillation using automated external defibrillator (AED) by bystander prior to emergency medical system (EMS) arrival was associated with favorable outcomes in out-of-hospital cardiac arrest (OHCA) of cardiac cause, whether it improves outcomes of OHCA due to non-cardiac cause is not clear. We aimed to investigate the impact of defibrillation with AED by bystander before defibrillation by EMS personnel on the outcomes of OHCA of presumed non-cardiac cause. METHODS: This was a retrospective cohort study using the All-Japan Utstein registry (reference period: 2013 to 2017). We included adult patients with OHCA of presumed non-cardiac cause, who had initial shockable rhythm, and who received witnessed arrest bystander cardiopulmonary resuscitation (CPR). Exposure variable was defibrillation with AED by bystander in comparison with initial defibrillation by EMS. Logistic regression analyses were conducted to assess the association between bystander AED shock and favorable neurological outcome (Cerebral Performance Category scale 1 or 2) at one month. RESULTS: Among the 1,053 patients included for analysis, 57 (5.4%) received bystander AED shock. There was no statistically significant difference in the rate of favorable neurological outcome at one month between groups [9 (15.8%) vs 109 (10.9%), p = 0.26]. Logistic regression analysis adjusted for characteristics, intervention, and time course of CPR showed no association between bystander AED shock and favorable neurological outcome [OR (95% CI): 1.63 (0.70–3.77), p = 0.25]. CONCLUSION: In this study, defibrillation with AED by bystander before defibrillation by EMS personnel was not associated with the favorable outcomes of OHCA of presumed non-cardiac cause.
format Online
Article
Text
id pubmed-9939706
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99397062023-02-21 Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology Komori, Akira Iriyama, Hiroki Abe, Toshikazu Resusc Plus Clinical Paper AIM OF THE STUDY: Although defibrillation using automated external defibrillator (AED) by bystander prior to emergency medical system (EMS) arrival was associated with favorable outcomes in out-of-hospital cardiac arrest (OHCA) of cardiac cause, whether it improves outcomes of OHCA due to non-cardiac cause is not clear. We aimed to investigate the impact of defibrillation with AED by bystander before defibrillation by EMS personnel on the outcomes of OHCA of presumed non-cardiac cause. METHODS: This was a retrospective cohort study using the All-Japan Utstein registry (reference period: 2013 to 2017). We included adult patients with OHCA of presumed non-cardiac cause, who had initial shockable rhythm, and who received witnessed arrest bystander cardiopulmonary resuscitation (CPR). Exposure variable was defibrillation with AED by bystander in comparison with initial defibrillation by EMS. Logistic regression analyses were conducted to assess the association between bystander AED shock and favorable neurological outcome (Cerebral Performance Category scale 1 or 2) at one month. RESULTS: Among the 1,053 patients included for analysis, 57 (5.4%) received bystander AED shock. There was no statistically significant difference in the rate of favorable neurological outcome at one month between groups [9 (15.8%) vs 109 (10.9%), p = 0.26]. Logistic regression analysis adjusted for characteristics, intervention, and time course of CPR showed no association between bystander AED shock and favorable neurological outcome [OR (95% CI): 1.63 (0.70–3.77), p = 0.25]. CONCLUSION: In this study, defibrillation with AED by bystander before defibrillation by EMS personnel was not associated with the favorable outcomes of OHCA of presumed non-cardiac cause. Elsevier 2023-02-07 /pmc/articles/PMC9939706/ /pubmed/36814461 http://dx.doi.org/10.1016/j.resplu.2023.100363 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical Paper
Komori, Akira
Iriyama, Hiroki
Abe, Toshikazu
Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
title Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
title_full Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
title_fullStr Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
title_full_unstemmed Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
title_short Impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
title_sort impact of defibrillation with automated external defibrillator by bystander before defibrillation by emergency medical system personnel on neurological outcome of out-of-hospital cardiac arrest with non-cardiac etiology
topic Clinical Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9939706/
https://www.ncbi.nlm.nih.gov/pubmed/36814461
http://dx.doi.org/10.1016/j.resplu.2023.100363
work_keys_str_mv AT komoriakira impactofdefibrillationwithautomatedexternaldefibrillatorbybystanderbeforedefibrillationbyemergencymedicalsystempersonnelonneurologicaloutcomeofoutofhospitalcardiacarrestwithnoncardiacetiology
AT iriyamahiroki impactofdefibrillationwithautomatedexternaldefibrillatorbybystanderbeforedefibrillationbyemergencymedicalsystempersonnelonneurologicaloutcomeofoutofhospitalcardiacarrestwithnoncardiacetiology
AT abetoshikazu impactofdefibrillationwithautomatedexternaldefibrillatorbybystanderbeforedefibrillationbyemergencymedicalsystempersonnelonneurologicaloutcomeofoutofhospitalcardiacarrestwithnoncardiacetiology