Cargando…
Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract
BACKGROUND: Limited information is available about neonates’ critical conditions data quality. The study aim was to measure the agreement regarding presence of neonatal critical conditions between Medicaid Analytic eXtract claims data and Birth Certificate (BC) records. METHODS: Claims data files of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9940322/ https://www.ncbi.nlm.nih.gov/pubmed/36803103 http://dx.doi.org/10.1186/s12874-023-01860-5 |
_version_ | 1784891052804538368 |
---|---|
author | Albogami, Yasser Zhu, Yanmin Wang, Xi Winterstein, Almut G |
author_facet | Albogami, Yasser Zhu, Yanmin Wang, Xi Winterstein, Almut G |
author_sort | Albogami, Yasser |
collection | PubMed |
description | BACKGROUND: Limited information is available about neonates’ critical conditions data quality. The study aim was to measure the agreement regarding presence of neonatal critical conditions between Medicaid Analytic eXtract claims data and Birth Certificate (BC) records. METHODS: Claims data files of neonates born between 1999–2010 and their mothers were linked to birth certificates in the states of Texas and Florida. In claims data, neonatal critical conditions were identified using medical encounter claims records within the first 30 days postpartum, while in birth certificates, the conditions were identified based on predetermined variables. We calculated the prevalence of cases within each data source that were identified by its comparator, in addition to calculating overall agreement and kappa statistics. RESULTS: The sample included 558,224 and 981,120 neonates in Florida and Texas, respectively. Kappa values show poor agreement (< 20%) for all critical conditions except neonatal intensive care unit (NICU) admission, which showed moderate (> 50%) and substantial (> 60%) agreement in Florida and Texas, respectively. claims data resulted in higher prevalences and capture of a larger proportion of cases than the BC, except for assisted ventilation. CONCLUSIONS: Claims data and BC showed low agreement on neonatal critical conditions except for NICU admission. Each data source identified cases most of which the comparator failed to capture, with higher prevalences estimated within claims data except for assisted ventilation. |
format | Online Article Text |
id | pubmed-9940322 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99403222023-02-21 Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract Albogami, Yasser Zhu, Yanmin Wang, Xi Winterstein, Almut G BMC Med Res Methodol Research BACKGROUND: Limited information is available about neonates’ critical conditions data quality. The study aim was to measure the agreement regarding presence of neonatal critical conditions between Medicaid Analytic eXtract claims data and Birth Certificate (BC) records. METHODS: Claims data files of neonates born between 1999–2010 and their mothers were linked to birth certificates in the states of Texas and Florida. In claims data, neonatal critical conditions were identified using medical encounter claims records within the first 30 days postpartum, while in birth certificates, the conditions were identified based on predetermined variables. We calculated the prevalence of cases within each data source that were identified by its comparator, in addition to calculating overall agreement and kappa statistics. RESULTS: The sample included 558,224 and 981,120 neonates in Florida and Texas, respectively. Kappa values show poor agreement (< 20%) for all critical conditions except neonatal intensive care unit (NICU) admission, which showed moderate (> 50%) and substantial (> 60%) agreement in Florida and Texas, respectively. claims data resulted in higher prevalences and capture of a larger proportion of cases than the BC, except for assisted ventilation. CONCLUSIONS: Claims data and BC showed low agreement on neonatal critical conditions except for NICU admission. Each data source identified cases most of which the comparator failed to capture, with higher prevalences estimated within claims data except for assisted ventilation. BioMed Central 2023-02-20 /pmc/articles/PMC9940322/ /pubmed/36803103 http://dx.doi.org/10.1186/s12874-023-01860-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Albogami, Yasser Zhu, Yanmin Wang, Xi Winterstein, Almut G Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract |
title | Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract |
title_full | Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract |
title_fullStr | Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract |
title_full_unstemmed | Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract |
title_short | Concordance of neonatal critical condition data between secondary databases: Florida and Texas birth certificate Linkage with medicaid analytic extract |
title_sort | concordance of neonatal critical condition data between secondary databases: florida and texas birth certificate linkage with medicaid analytic extract |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9940322/ https://www.ncbi.nlm.nih.gov/pubmed/36803103 http://dx.doi.org/10.1186/s12874-023-01860-5 |
work_keys_str_mv | AT albogamiyasser concordanceofneonatalcriticalconditiondatabetweensecondarydatabasesfloridaandtexasbirthcertificatelinkagewithmedicaidanalyticextract AT zhuyanmin concordanceofneonatalcriticalconditiondatabetweensecondarydatabasesfloridaandtexasbirthcertificatelinkagewithmedicaidanalyticextract AT wangxi concordanceofneonatalcriticalconditiondatabetweensecondarydatabasesfloridaandtexasbirthcertificatelinkagewithmedicaidanalyticextract AT wintersteinalmutg concordanceofneonatalcriticalconditiondatabetweensecondarydatabasesfloridaandtexasbirthcertificatelinkagewithmedicaidanalyticextract |