Cargando…

A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note

There are various techniques used for tendon lengthening, of which Z-lengthening and sliding-lengthening are the most frequently performed. In patients with cerebral palsy, tendon lengthening may often be necessary at multiple sites. However, they can cause various complications, such as inaccurate...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwase, Dai, Metoki, Yukie, Aikawa, Jun, Uchida, Kentaro, Fukushima, Kensuke, Matsuo, Takashi, Matsuo, Atsushi, Inoue, Gen, Takaso, Masashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer India 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9941377/
https://www.ncbi.nlm.nih.gov/pubmed/36825275
http://dx.doi.org/10.1007/s43465-023-00829-2
_version_ 1784891273589555200
author Iwase, Dai
Metoki, Yukie
Aikawa, Jun
Uchida, Kentaro
Fukushima, Kensuke
Matsuo, Takashi
Matsuo, Atsushi
Inoue, Gen
Takaso, Masashi
author_facet Iwase, Dai
Metoki, Yukie
Aikawa, Jun
Uchida, Kentaro
Fukushima, Kensuke
Matsuo, Takashi
Matsuo, Atsushi
Inoue, Gen
Takaso, Masashi
author_sort Iwase, Dai
collection PubMed
description There are various techniques used for tendon lengthening, of which Z-lengthening and sliding-lengthening are the most frequently performed. In patients with cerebral palsy, tendon lengthening may often be necessary at multiple sites. However, they can cause various complications, such as inaccurate extension, overextension, and a lack of tendon continuity. We modified the sliding-lengthening technique with a locking mechanism to address these issues. This technical note aims to describe the surgical technique and pitfalls associated with the modified sliding-lengthening approach and suture locking mechanism. The tendon was exposed and stabilized using sterilized spitz tubes and was then threaded so that each loop length was equivalent to the amount of tendon extension. Symmetrical hemisection of both ends of the tendon was performed, and the tendon was carefully extended to create a tense loop. The modified sliding-lengthening technique with the locking suture mechanism may be an advantageous method that accurately addresses extension volume, prevents hyperextension, and maintains tendon continuity, even when smaller incisions are used.
format Online
Article
Text
id pubmed-9941377
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer India
record_format MEDLINE/PubMed
spelling pubmed-99413772023-02-22 A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note Iwase, Dai Metoki, Yukie Aikawa, Jun Uchida, Kentaro Fukushima, Kensuke Matsuo, Takashi Matsuo, Atsushi Inoue, Gen Takaso, Masashi Indian J Orthop Surgical Technique There are various techniques used for tendon lengthening, of which Z-lengthening and sliding-lengthening are the most frequently performed. In patients with cerebral palsy, tendon lengthening may often be necessary at multiple sites. However, they can cause various complications, such as inaccurate extension, overextension, and a lack of tendon continuity. We modified the sliding-lengthening technique with a locking mechanism to address these issues. This technical note aims to describe the surgical technique and pitfalls associated with the modified sliding-lengthening approach and suture locking mechanism. The tendon was exposed and stabilized using sterilized spitz tubes and was then threaded so that each loop length was equivalent to the amount of tendon extension. Symmetrical hemisection of both ends of the tendon was performed, and the tendon was carefully extended to create a tense loop. The modified sliding-lengthening technique with the locking suture mechanism may be an advantageous method that accurately addresses extension volume, prevents hyperextension, and maintains tendon continuity, even when smaller incisions are used. Springer India 2023-01-30 /pmc/articles/PMC9941377/ /pubmed/36825275 http://dx.doi.org/10.1007/s43465-023-00829-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Surgical Technique
Iwase, Dai
Metoki, Yukie
Aikawa, Jun
Uchida, Kentaro
Fukushima, Kensuke
Matsuo, Takashi
Matsuo, Atsushi
Inoue, Gen
Takaso, Masashi
A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
title A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
title_full A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
title_fullStr A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
title_full_unstemmed A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
title_short A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
title_sort modified sliding-lengthening approach to tendon lengthening with a locking mechanism suture: a technical note
topic Surgical Technique
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9941377/
https://www.ncbi.nlm.nih.gov/pubmed/36825275
http://dx.doi.org/10.1007/s43465-023-00829-2
work_keys_str_mv AT iwasedai amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT metokiyukie amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT aikawajun amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT uchidakentaro amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT fukushimakensuke amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT matsuotakashi amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT matsuoatsushi amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT inouegen amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT takasomasashi amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT iwasedai modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT metokiyukie modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT aikawajun modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT uchidakentaro modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT fukushimakensuke modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT matsuotakashi modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT matsuoatsushi modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT inouegen modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote
AT takasomasashi modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote