Cargando…
A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note
There are various techniques used for tendon lengthening, of which Z-lengthening and sliding-lengthening are the most frequently performed. In patients with cerebral palsy, tendon lengthening may often be necessary at multiple sites. However, they can cause various complications, such as inaccurate...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer India
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9941377/ https://www.ncbi.nlm.nih.gov/pubmed/36825275 http://dx.doi.org/10.1007/s43465-023-00829-2 |
_version_ | 1784891273589555200 |
---|---|
author | Iwase, Dai Metoki, Yukie Aikawa, Jun Uchida, Kentaro Fukushima, Kensuke Matsuo, Takashi Matsuo, Atsushi Inoue, Gen Takaso, Masashi |
author_facet | Iwase, Dai Metoki, Yukie Aikawa, Jun Uchida, Kentaro Fukushima, Kensuke Matsuo, Takashi Matsuo, Atsushi Inoue, Gen Takaso, Masashi |
author_sort | Iwase, Dai |
collection | PubMed |
description | There are various techniques used for tendon lengthening, of which Z-lengthening and sliding-lengthening are the most frequently performed. In patients with cerebral palsy, tendon lengthening may often be necessary at multiple sites. However, they can cause various complications, such as inaccurate extension, overextension, and a lack of tendon continuity. We modified the sliding-lengthening technique with a locking mechanism to address these issues. This technical note aims to describe the surgical technique and pitfalls associated with the modified sliding-lengthening approach and suture locking mechanism. The tendon was exposed and stabilized using sterilized spitz tubes and was then threaded so that each loop length was equivalent to the amount of tendon extension. Symmetrical hemisection of both ends of the tendon was performed, and the tendon was carefully extended to create a tense loop. The modified sliding-lengthening technique with the locking suture mechanism may be an advantageous method that accurately addresses extension volume, prevents hyperextension, and maintains tendon continuity, even when smaller incisions are used. |
format | Online Article Text |
id | pubmed-9941377 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer India |
record_format | MEDLINE/PubMed |
spelling | pubmed-99413772023-02-22 A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note Iwase, Dai Metoki, Yukie Aikawa, Jun Uchida, Kentaro Fukushima, Kensuke Matsuo, Takashi Matsuo, Atsushi Inoue, Gen Takaso, Masashi Indian J Orthop Surgical Technique There are various techniques used for tendon lengthening, of which Z-lengthening and sliding-lengthening are the most frequently performed. In patients with cerebral palsy, tendon lengthening may often be necessary at multiple sites. However, they can cause various complications, such as inaccurate extension, overextension, and a lack of tendon continuity. We modified the sliding-lengthening technique with a locking mechanism to address these issues. This technical note aims to describe the surgical technique and pitfalls associated with the modified sliding-lengthening approach and suture locking mechanism. The tendon was exposed and stabilized using sterilized spitz tubes and was then threaded so that each loop length was equivalent to the amount of tendon extension. Symmetrical hemisection of both ends of the tendon was performed, and the tendon was carefully extended to create a tense loop. The modified sliding-lengthening technique with the locking suture mechanism may be an advantageous method that accurately addresses extension volume, prevents hyperextension, and maintains tendon continuity, even when smaller incisions are used. Springer India 2023-01-30 /pmc/articles/PMC9941377/ /pubmed/36825275 http://dx.doi.org/10.1007/s43465-023-00829-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Surgical Technique Iwase, Dai Metoki, Yukie Aikawa, Jun Uchida, Kentaro Fukushima, Kensuke Matsuo, Takashi Matsuo, Atsushi Inoue, Gen Takaso, Masashi A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note |
title | A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note |
title_full | A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note |
title_fullStr | A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note |
title_full_unstemmed | A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note |
title_short | A Modified Sliding-Lengthening Approach to Tendon Lengthening with a Locking Mechanism Suture: A Technical Note |
title_sort | modified sliding-lengthening approach to tendon lengthening with a locking mechanism suture: a technical note |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9941377/ https://www.ncbi.nlm.nih.gov/pubmed/36825275 http://dx.doi.org/10.1007/s43465-023-00829-2 |
work_keys_str_mv | AT iwasedai amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT metokiyukie amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT aikawajun amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT uchidakentaro amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT fukushimakensuke amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT matsuotakashi amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT matsuoatsushi amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT inouegen amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT takasomasashi amodifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT iwasedai modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT metokiyukie modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT aikawajun modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT uchidakentaro modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT fukushimakensuke modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT matsuotakashi modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT matsuoatsushi modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT inouegen modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote AT takasomasashi modifiedslidinglengtheningapproachtotendonlengtheningwithalockingmechanismsutureatechnicalnote |