Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report

Carbon-ion radiotherapy (CIRT) for prostate cancer is both safe and efficacious; beam range calculations use relative stopping power ratio, which is derived from computed tomography (CT) values. However, hip prostheses are made of high atomic number materials and show severe artifacts on CT images....

Descripción completa

Detalles Bibliográficos
Autores principales: Takakusagi, Yosuke, Takayama, Yoshiki, Kusano, Yohsuke, Koge, Hiroaki, Kano, Kio, Shima, Satoshi, Tsuchida, Keisuke, Mizoguchi, Nobutaka, Yoshida, Daisaku, Kamada, Tadashi, Miyakawa, Shin, Imura, Koh, Katoh, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9941787/
https://www.ncbi.nlm.nih.gov/pubmed/36825095
http://dx.doi.org/10.1159/000526932
_version_ 1784891362456371200
author Takakusagi, Yosuke
Takayama, Yoshiki
Kusano, Yohsuke
Koge, Hiroaki
Kano, Kio
Shima, Satoshi
Tsuchida, Keisuke
Mizoguchi, Nobutaka
Yoshida, Daisaku
Kamada, Tadashi
Miyakawa, Shin
Imura, Koh
Katoh, Hiroyuki
author_facet Takakusagi, Yosuke
Takayama, Yoshiki
Kusano, Yohsuke
Koge, Hiroaki
Kano, Kio
Shima, Satoshi
Tsuchida, Keisuke
Mizoguchi, Nobutaka
Yoshida, Daisaku
Kamada, Tadashi
Miyakawa, Shin
Imura, Koh
Katoh, Hiroyuki
author_sort Takakusagi, Yosuke
collection PubMed
description Carbon-ion radiotherapy (CIRT) for prostate cancer is both safe and efficacious; beam range calculations use relative stopping power ratio, which is derived from computed tomography (CT) values. However, hip prostheses are made of high atomic number materials and show severe artifacts on CT images. Therefore, it is not possible to accurately calculate dose distribution for CIRT in patients with prostate cancer with hip prostheses. Here, we describe the management of a 77-year-old man with prostate cancer who had previously undergone bilateral hip replacement. CIRT, in combination with androgen deprivation therapy, was recommended as definitive treatment for prostate cancer. Planning CT, magnetic resonance (MRI), and CT images with metal artifact reduction (MAR) were acquired for CIRT planning. MRI and MAR images were superimposed on the planning CT to delineate target volume and organs at risk. The radiation treatment plan consisted of a total dose of 51.6 Gy (relative biological effect) to be delivered in 12 fractions over 3 weeks, and the patient was irradiated in the supine and prone positions with a vertical beam, on alternating days. CIRT was completed as scheduled. No adverse events were observed during treatment or at 3 months after treatment initiation. While we show that CIRT may be a treatment option for patients with prostate cancer with bilateral hip prostheses, further studies are needed to evaluate treatment efficacy and late toxicity and to determine how CIRT can be administered to patients with prostate cancer with bilateral hip prostheses.
format Online
Article
Text
id pubmed-9941787
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-99417872023-02-22 Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report Takakusagi, Yosuke Takayama, Yoshiki Kusano, Yohsuke Koge, Hiroaki Kano, Kio Shima, Satoshi Tsuchida, Keisuke Mizoguchi, Nobutaka Yoshida, Daisaku Kamada, Tadashi Miyakawa, Shin Imura, Koh Katoh, Hiroyuki Case Rep Oncol Case Report Carbon-ion radiotherapy (CIRT) for prostate cancer is both safe and efficacious; beam range calculations use relative stopping power ratio, which is derived from computed tomography (CT) values. However, hip prostheses are made of high atomic number materials and show severe artifacts on CT images. Therefore, it is not possible to accurately calculate dose distribution for CIRT in patients with prostate cancer with hip prostheses. Here, we describe the management of a 77-year-old man with prostate cancer who had previously undergone bilateral hip replacement. CIRT, in combination with androgen deprivation therapy, was recommended as definitive treatment for prostate cancer. Planning CT, magnetic resonance (MRI), and CT images with metal artifact reduction (MAR) were acquired for CIRT planning. MRI and MAR images were superimposed on the planning CT to delineate target volume and organs at risk. The radiation treatment plan consisted of a total dose of 51.6 Gy (relative biological effect) to be delivered in 12 fractions over 3 weeks, and the patient was irradiated in the supine and prone positions with a vertical beam, on alternating days. CIRT was completed as scheduled. No adverse events were observed during treatment or at 3 months after treatment initiation. While we show that CIRT may be a treatment option for patients with prostate cancer with bilateral hip prostheses, further studies are needed to evaluate treatment efficacy and late toxicity and to determine how CIRT can be administered to patients with prostate cancer with bilateral hip prostheses. S. Karger AG 2022-10-03 /pmc/articles/PMC9941787/ /pubmed/36825095 http://dx.doi.org/10.1159/000526932 Text en Copyright © 2022 by The Author(s). Published by S. Karger AG, Basel https://creativecommons.org/licenses/by-nc/4.0/This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission.
spellingShingle Case Report
Takakusagi, Yosuke
Takayama, Yoshiki
Kusano, Yohsuke
Koge, Hiroaki
Kano, Kio
Shima, Satoshi
Tsuchida, Keisuke
Mizoguchi, Nobutaka
Yoshida, Daisaku
Kamada, Tadashi
Miyakawa, Shin
Imura, Koh
Katoh, Hiroyuki
Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report
title Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report
title_full Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report
title_fullStr Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report
title_full_unstemmed Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report
title_short Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report
title_sort carbon-ion radiotherapy using metal artifact reduction computed tomography in a patient with prostate cancer with bilateral hip prostheses: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9941787/
https://www.ncbi.nlm.nih.gov/pubmed/36825095
http://dx.doi.org/10.1159/000526932
work_keys_str_mv AT takakusagiyosuke carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT takayamayoshiki carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT kusanoyohsuke carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT kogehiroaki carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT kanokio carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT shimasatoshi carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT tsuchidakeisuke carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT mizoguchinobutaka carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT yoshidadaisaku carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT kamadatadashi carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT miyakawashin carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT imurakoh carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport
AT katohhiroyuki carbonionradiotherapyusingmetalartifactreductioncomputedtomographyinapatientwithprostatecancerwithbilateralhipprosthesesacasereport