NiFe-based Prussian blue analogue nanopolygons hybridized with functionalized glyoxal polymer as a voltammetric platform for the determination of amisulpride in biological samples
A novel voltammetric platform based on pencil graphite electrode (PGE) modification has been proposed, containing bimetallic (NiFe) Prussian blue analogue nanopolygons decorated with electro-polymerized glyoxal polymer nanocomposites (p-DPG NCs@NiFe PBA Ns/PGE). Cyclic voltammetry (CV), electrochemi...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9942618/ https://www.ncbi.nlm.nih.gov/pubmed/36807994 http://dx.doi.org/10.1007/s00216-023-04559-0 |
Sumario: | A novel voltammetric platform based on pencil graphite electrode (PGE) modification has been proposed, containing bimetallic (NiFe) Prussian blue analogue nanopolygons decorated with electro-polymerized glyoxal polymer nanocomposites (p-DPG NCs@NiFe PBA Ns/PGE). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV) were utilized to investigate the electrochemical performance of the proposed sensor. The analytical response of p-DPG NCs@NiFe PBA Ns/PGE was evaluated through the quantity of amisulpride (AMS), one of the most common antipsychotic drugs. Under the optimized experimental and instrumental conditions, the method showed linearity over the range from 0.5 to 15 × 10(−8) mol L(−1) with a good correlation coefficient (R = 0.9995) and a low detection limit (LOD) reached, 1.5 nmol L(−1), with excellent relative standard deviation for human plasma and urine samples. The interference effect of some potentially interfering substances was negligible, and the sensing platform demonstrated an outstanding reproducibility, stability, and reusability. As a first trial, the proposed electrode aimed to shed light on the AMS oxidation mechanism, where the oxidation mechanism was monitored and elucidated using the FTIR technique. It was also found that the prepared p-DPG NCs@NiFe PBA Ns/PGE platform had promising applications for the simultaneous determination of AMS in the presence of some co-administered COVID-19 drugs, which could be attributed to the large active surface area, and high conductivity of bimetallic nanopolygons. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04559-0. |
---|