Cargando…

Glycaemic Control in People with Type 2 Diabetes Mellitus Switching from Basal Insulin to Insulin Glargine 300 U/ml (Gla-300): Results from the REALI Pooled Database

INTRODUCTION: Using pooled data from the REALI European database, we evaluated the impact of previous basal insulin (BI) type on real-life effectiveness and safety of switching to insulin glargine 300 U/ml (Gla-300) in people with suboptimally controlled type 2 diabetes. METHODS: Patient-level data...

Descripción completa

Detalles Bibliográficos
Autores principales: Müller-Wieland, Dirk, Freemantle, Nick, Bonadonna, Riccardo C., Mauquoi, Celine, Bigot, Gregory, Bonnemaire, Mireille, Gourdy, Pierre, Mauricio, Didac
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9943923/
https://www.ncbi.nlm.nih.gov/pubmed/36596946
http://dx.doi.org/10.1007/s13300-022-01356-3
Descripción
Sumario:INTRODUCTION: Using pooled data from the REALI European database, we evaluated the impact of previous basal insulin (BI) type on real-life effectiveness and safety of switching to insulin glargine 300 U/ml (Gla-300) in people with suboptimally controlled type 2 diabetes. METHODS: Patient-level data were pooled from 11 prospective, open-label, 24-week studies. Participants were classified according to the type of prior BI. Of the 4463 participants, 1282 (28.7%) were pre-treated with neutral protamine Hagedorn (NPH) insulin and 2899 (65.0%) with BI analogues (BIAs), and 282 (6.3%) had undetermined prior BI. RESULTS: There were no meaningful differences in baseline characteristics between subgroups, except for a higher prevalence of diabetic neuropathy in the NPH subgroup (21.6% versus 7.8% with BIAs). Mean ± standard deviation haemoglobin A1c (HbA1c) decreased from 8.73 ± 1.15% and 8.35 ± 0.95% at baseline to 7.71 ± 1.09% and 7.82 ± 1.06% at week 24 in the NPH and BIA subgroups, respectively. Least squares (LS) mean change in HbA1c was − 0.85% (95% confidence interval − 0.94 to − 0.77) in NPH subgroup and − 0.70% (− 0.77 to − 0.64) in BIA subgroup, with a LS mean absolute difference between subgroups of 0.16 (0.06–0.26; p = 0.002). Gla-300 mean daily dose was slightly increased at week 24 by 0.07 U/kg/day (approximately 6 U/day) in both subgroups. Incidences of symptomatic and severe hypoglycaemia were low, without body weight change. CONCLUSIONS: Irrespective of previous BI therapy (NPH insulin or BIAs), switching to Gla-300 improved glycaemic control without weight gain and with low symptomatic and severe hypoglycaemia incidences. However, a slightly greater glucose-lowering effectiveness was observed in people pre-treated with NPH insulin.