Cargando…

Experimental environment improves the reliability of short-latency afferent inhibition

Evidence indicates attention can alter afferent inhibition, a Transcranial Magnetic Stimulation (TMS) evoked measure of cortical inhibition following somatosensory input. When peripheral nerve stimulation is delivered prior to TMS, a phenomenon known as afferent inhibition occurs. The latency betwee...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramdeo, Karishma R., Rehsi, Ravjot S., Foglia, Stevie D., Turco, Claudia V., Toepp, Stephen L., Nelson, Aimee J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9946256/
https://www.ncbi.nlm.nih.gov/pubmed/36812217
http://dx.doi.org/10.1371/journal.pone.0281867
_version_ 1784892295401701376
author Ramdeo, Karishma R.
Rehsi, Ravjot S.
Foglia, Stevie D.
Turco, Claudia V.
Toepp, Stephen L.
Nelson, Aimee J.
author_facet Ramdeo, Karishma R.
Rehsi, Ravjot S.
Foglia, Stevie D.
Turco, Claudia V.
Toepp, Stephen L.
Nelson, Aimee J.
author_sort Ramdeo, Karishma R.
collection PubMed
description Evidence indicates attention can alter afferent inhibition, a Transcranial Magnetic Stimulation (TMS) evoked measure of cortical inhibition following somatosensory input. When peripheral nerve stimulation is delivered prior to TMS, a phenomenon known as afferent inhibition occurs. The latency between the peripheral nerve stimulation dictates the subtype of afferent inhibition evoked, either short latency afferent inhibition (SAI) or long latency afferent inhibition (LAI). While afferent inhibition is emerging as a valuable tool for clinical assessment of sensorimotor function, the reliability of the measure remains relatively low. Therefore, to improve the translation of afferent inhibition within and beyond the research lab, the reliability of the measure must be improved. Previous literature suggests that the focus of attention can modify the magnitude of afferent inhibition. As such, controlling the focus of attention may be one method to improve the reliability of afferent inhibition. In the present study, the magnitude and reliability of SAI and LAI was assessed under four conditions with varying attentional demands focused on the somatosensory input that evokes SAI and LAI circuits. Thirty individuals participated in four conditions; three conditions were identical in their physical parameters and varied only in the focus of directed attention (visual attend, tactile attend, non- directed attend) and one condition consisted of no external physical parameters (no stimulation). Reliability was measured by repeating conditions at three time points to assess intrasession and intersession reliability. Results indicate that the magnitude of SAI and LAI were not modulated by attention. However, the reliability of SAI demonstrated increased intrasession and intersession reliability compared to the no stimulation condition. The reliability of LAI was unaffected by the attention conditions. This research demonstrates the impact of attention/arousal on the reliability of afferent inhibition and has identified new parameters to inform the design of TMS research to improve reliability.
format Online
Article
Text
id pubmed-9946256
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-99462562023-02-23 Experimental environment improves the reliability of short-latency afferent inhibition Ramdeo, Karishma R. Rehsi, Ravjot S. Foglia, Stevie D. Turco, Claudia V. Toepp, Stephen L. Nelson, Aimee J. PLoS One Research Article Evidence indicates attention can alter afferent inhibition, a Transcranial Magnetic Stimulation (TMS) evoked measure of cortical inhibition following somatosensory input. When peripheral nerve stimulation is delivered prior to TMS, a phenomenon known as afferent inhibition occurs. The latency between the peripheral nerve stimulation dictates the subtype of afferent inhibition evoked, either short latency afferent inhibition (SAI) or long latency afferent inhibition (LAI). While afferent inhibition is emerging as a valuable tool for clinical assessment of sensorimotor function, the reliability of the measure remains relatively low. Therefore, to improve the translation of afferent inhibition within and beyond the research lab, the reliability of the measure must be improved. Previous literature suggests that the focus of attention can modify the magnitude of afferent inhibition. As such, controlling the focus of attention may be one method to improve the reliability of afferent inhibition. In the present study, the magnitude and reliability of SAI and LAI was assessed under four conditions with varying attentional demands focused on the somatosensory input that evokes SAI and LAI circuits. Thirty individuals participated in four conditions; three conditions were identical in their physical parameters and varied only in the focus of directed attention (visual attend, tactile attend, non- directed attend) and one condition consisted of no external physical parameters (no stimulation). Reliability was measured by repeating conditions at three time points to assess intrasession and intersession reliability. Results indicate that the magnitude of SAI and LAI were not modulated by attention. However, the reliability of SAI demonstrated increased intrasession and intersession reliability compared to the no stimulation condition. The reliability of LAI was unaffected by the attention conditions. This research demonstrates the impact of attention/arousal on the reliability of afferent inhibition and has identified new parameters to inform the design of TMS research to improve reliability. Public Library of Science 2023-02-22 /pmc/articles/PMC9946256/ /pubmed/36812217 http://dx.doi.org/10.1371/journal.pone.0281867 Text en © 2023 Ramdeo et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ramdeo, Karishma R.
Rehsi, Ravjot S.
Foglia, Stevie D.
Turco, Claudia V.
Toepp, Stephen L.
Nelson, Aimee J.
Experimental environment improves the reliability of short-latency afferent inhibition
title Experimental environment improves the reliability of short-latency afferent inhibition
title_full Experimental environment improves the reliability of short-latency afferent inhibition
title_fullStr Experimental environment improves the reliability of short-latency afferent inhibition
title_full_unstemmed Experimental environment improves the reliability of short-latency afferent inhibition
title_short Experimental environment improves the reliability of short-latency afferent inhibition
title_sort experimental environment improves the reliability of short-latency afferent inhibition
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9946256/
https://www.ncbi.nlm.nih.gov/pubmed/36812217
http://dx.doi.org/10.1371/journal.pone.0281867
work_keys_str_mv AT ramdeokarishmar experimentalenvironmentimprovesthereliabilityofshortlatencyafferentinhibition
AT rehsiravjots experimentalenvironmentimprovesthereliabilityofshortlatencyafferentinhibition
AT fogliastevied experimentalenvironmentimprovesthereliabilityofshortlatencyafferentinhibition
AT turcoclaudiav experimentalenvironmentimprovesthereliabilityofshortlatencyafferentinhibition
AT toeppstephenl experimentalenvironmentimprovesthereliabilityofshortlatencyafferentinhibition
AT nelsonaimeej experimentalenvironmentimprovesthereliabilityofshortlatencyafferentinhibition