Adaptive aberration correction using an electrowetting array

We demonstrate a method that permits wavefront aberration correction using an array of electrowetting prisms. A fixed high fill factor microlens array followed by a lower fill factor adaptive electrowetting prism array is used to correct wavefront aberration. The design and simulation of such aberra...

Descripción completa

Detalles Bibliográficos
Autores principales: Zohrabi, Mo, Lim, Wei Yang, Gilinsky, Samuel, Bright, Victor M., Gopinath, Juliet T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AIP Publishing LLC 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9946697/
https://www.ncbi.nlm.nih.gov/pubmed/36846091
http://dx.doi.org/10.1063/5.0133473
Descripción
Sumario:We demonstrate a method that permits wavefront aberration correction using an array of electrowetting prisms. A fixed high fill factor microlens array followed by a lower fill factor adaptive electrowetting prism array is used to correct wavefront aberration. The design and simulation of such aberration correction mechanism is described. Our results show significant improvement to the Strehl ratio by using our aberration correction scheme which results in diffraction limited performance. Compactness and effectiveness of our design can be implemented in many applications that require aberration correction, such as microscopy and consumer electronics.