Cargando…

The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS

Methods for determination of elements in various types of samples are generally considered to be very precise and highly accurate. For reliable analysis of elements Na, Mg and Ni in food samples is it worthwhile to perform an extensive method validation of high-resolution continuum source flame atom...

Descripción completa

Detalles Bibliográficos
Autores principales: Andersen, Jens E.T., Moemedi, Keaboletse, Katse, Kebabonye
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9947278/
https://www.ncbi.nlm.nih.gov/pubmed/36846684
http://dx.doi.org/10.1016/j.heliyon.2023.e13562
_version_ 1784892516703666176
author Andersen, Jens E.T.
Moemedi, Keaboletse
Katse, Kebabonye
author_facet Andersen, Jens E.T.
Moemedi, Keaboletse
Katse, Kebabonye
author_sort Andersen, Jens E.T.
collection PubMed
description Methods for determination of elements in various types of samples are generally considered to be very precise and highly accurate. For reliable analysis of elements Na, Mg and Ni in food samples is it worthwhile to perform an extensive method validation of high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) according to the principle of pooled calibrations (PoPC). Under routine laboratory conditions of analysis, elevated levels of relative uncertainty of measurement reaching values of more than 50% were detected, which jeopardized the validity of results, even when the measurements in the present study were performed with samples of tap water and borehole water. Comparison of relative uncertainties with corresponding literature results indicates that sample-signal differences may be due to detector noise rather than specimen variations.
format Online
Article
Text
id pubmed-9947278
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99472782023-02-24 The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS Andersen, Jens E.T. Moemedi, Keaboletse Katse, Kebabonye Heliyon Research Article Methods for determination of elements in various types of samples are generally considered to be very precise and highly accurate. For reliable analysis of elements Na, Mg and Ni in food samples is it worthwhile to perform an extensive method validation of high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) according to the principle of pooled calibrations (PoPC). Under routine laboratory conditions of analysis, elevated levels of relative uncertainty of measurement reaching values of more than 50% were detected, which jeopardized the validity of results, even when the measurements in the present study were performed with samples of tap water and borehole water. Comparison of relative uncertainties with corresponding literature results indicates that sample-signal differences may be due to detector noise rather than specimen variations. Elsevier 2023-02-08 /pmc/articles/PMC9947278/ /pubmed/36846684 http://dx.doi.org/10.1016/j.heliyon.2023.e13562 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Andersen, Jens E.T.
Moemedi, Keaboletse
Katse, Kebabonye
The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS
title The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS
title_full The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS
title_fullStr The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS
title_full_unstemmed The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS
title_short The principle of pooled calibrations delivers full correspondence between uncertainties of measurements of Na, Mg and Ni when determined using HR-CS FAAS
title_sort principle of pooled calibrations delivers full correspondence between uncertainties of measurements of na, mg and ni when determined using hr-cs faas
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9947278/
https://www.ncbi.nlm.nih.gov/pubmed/36846684
http://dx.doi.org/10.1016/j.heliyon.2023.e13562
work_keys_str_mv AT andersenjenset theprincipleofpooledcalibrationsdeliversfullcorrespondencebetweenuncertaintiesofmeasurementsofnamgandniwhendeterminedusinghrcsfaas
AT moemedikeaboletse theprincipleofpooledcalibrationsdeliversfullcorrespondencebetweenuncertaintiesofmeasurementsofnamgandniwhendeterminedusinghrcsfaas
AT katsekebabonye theprincipleofpooledcalibrationsdeliversfullcorrespondencebetweenuncertaintiesofmeasurementsofnamgandniwhendeterminedusinghrcsfaas
AT andersenjenset principleofpooledcalibrationsdeliversfullcorrespondencebetweenuncertaintiesofmeasurementsofnamgandniwhendeterminedusinghrcsfaas
AT moemedikeaboletse principleofpooledcalibrationsdeliversfullcorrespondencebetweenuncertaintiesofmeasurementsofnamgandniwhendeterminedusinghrcsfaas
AT katsekebabonye principleofpooledcalibrationsdeliversfullcorrespondencebetweenuncertaintiesofmeasurementsofnamgandniwhendeterminedusinghrcsfaas