Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?

Objective  The immediate referral of patients with risk factors for placenta accreta spectrum (PAS) to specialized centers is recommended, thus favoring an early diagnosis and an interdisciplinary management. However, diagnostic errors are frequent, even in referral centers (RCs). We sought to evalu...

Descripción completa

Detalles Bibliográficos
Autores principales: Nieto-Calvache, Albaro José, Benavides-Calvache, Juan Pablo, Hidalgo, Alejandra, Padilla, Natalia, López-Tenorio, Jaime, Victoria, Alejandro, Rengifo, Martin, Mejía, Mauricio, Vergara-Galliadi, Lina María, Sinisterra-Díaz, Stiven Ernesto, Maya, Juliana, Zambrano, María Andrea, Burgos-Luna, Juan Manuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Revinter Publicações Ltda. 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9948072/
https://www.ncbi.nlm.nih.gov/pubmed/36067797
http://dx.doi.org/10.1055/s-0042-1751061
_version_ 1784892697879773184
author Nieto-Calvache, Albaro José
Benavides-Calvache, Juan Pablo
Hidalgo, Alejandra
Padilla, Natalia
López-Tenorio, Jaime
Victoria, Alejandro
Rengifo, Martin
Mejía, Mauricio
Vergara-Galliadi, Lina María
Sinisterra-Díaz, Stiven Ernesto
Maya, Juliana
Zambrano, María Andrea
Burgos-Luna, Juan Manuel
author_facet Nieto-Calvache, Albaro José
Benavides-Calvache, Juan Pablo
Hidalgo, Alejandra
Padilla, Natalia
López-Tenorio, Jaime
Victoria, Alejandro
Rengifo, Martin
Mejía, Mauricio
Vergara-Galliadi, Lina María
Sinisterra-Díaz, Stiven Ernesto
Maya, Juliana
Zambrano, María Andrea
Burgos-Luna, Juan Manuel
author_sort Nieto-Calvache, Albaro José
collection PubMed
description Objective  The immediate referral of patients with risk factors for placenta accreta spectrum (PAS) to specialized centers is recommended, thus favoring an early diagnosis and an interdisciplinary management. However, diagnostic errors are frequent, even in referral centers (RCs). We sought to evaluate the performance of the prenatal diagnosis for PAS in a Latin American hospital. Methods  A retrospective descriptive study including patients referred due to the suspicion of PAS was conducted. Data from the prenatal imaging studies were compared with the final diagnoses (intraoperative and/or histological). Results  A total of 162 patients were included in the present study. The median gestational age at the time of the first PAS suspicious ultrasound was 29 weeks, but patients arrived at the PAS RC at 34 weeks. The frequency of false-positive results at referring hospitals was 68.5%. Sixty-nine patients underwent surgery based on the suspicion of PAS at 35 weeks, and there was a 28.9% false-positive rate at the RC. In 93 patients, the diagnosis of PAS was ruled out at the RC, with a 2.1% false-negative frequency. Conclusion  The prenatal diagnosis of PAS is better at the RC. However, even in these centers, false-positive results are common; therefore, the intraoperative confirmation of the diagnosis of PAS is essential.
format Online
Article
Text
id pubmed-9948072
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Thieme Revinter Publicações Ltda.
record_format MEDLINE/PubMed
spelling pubmed-99480722023-07-27 Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings? Nieto-Calvache, Albaro José Benavides-Calvache, Juan Pablo Hidalgo, Alejandra Padilla, Natalia López-Tenorio, Jaime Victoria, Alejandro Rengifo, Martin Mejía, Mauricio Vergara-Galliadi, Lina María Sinisterra-Díaz, Stiven Ernesto Maya, Juliana Zambrano, María Andrea Burgos-Luna, Juan Manuel Rev Bras Ginecol Obstet Objective  The immediate referral of patients with risk factors for placenta accreta spectrum (PAS) to specialized centers is recommended, thus favoring an early diagnosis and an interdisciplinary management. However, diagnostic errors are frequent, even in referral centers (RCs). We sought to evaluate the performance of the prenatal diagnosis for PAS in a Latin American hospital. Methods  A retrospective descriptive study including patients referred due to the suspicion of PAS was conducted. Data from the prenatal imaging studies were compared with the final diagnoses (intraoperative and/or histological). Results  A total of 162 patients were included in the present study. The median gestational age at the time of the first PAS suspicious ultrasound was 29 weeks, but patients arrived at the PAS RC at 34 weeks. The frequency of false-positive results at referring hospitals was 68.5%. Sixty-nine patients underwent surgery based on the suspicion of PAS at 35 weeks, and there was a 28.9% false-positive rate at the RC. In 93 patients, the diagnosis of PAS was ruled out at the RC, with a 2.1% false-negative frequency. Conclusion  The prenatal diagnosis of PAS is better at the RC. However, even in these centers, false-positive results are common; therefore, the intraoperative confirmation of the diagnosis of PAS is essential. Thieme Revinter Publicações Ltda. 2022-09-06 /pmc/articles/PMC9948072/ /pubmed/36067797 http://dx.doi.org/10.1055/s-0042-1751061 Text en Federação Brasileira de Ginecologia e Obstetrícia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ) https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Nieto-Calvache, Albaro José
Benavides-Calvache, Juan Pablo
Hidalgo, Alejandra
Padilla, Natalia
López-Tenorio, Jaime
Victoria, Alejandro
Rengifo, Martin
Mejía, Mauricio
Vergara-Galliadi, Lina María
Sinisterra-Díaz, Stiven Ernesto
Maya, Juliana
Zambrano, María Andrea
Burgos-Luna, Juan Manuel
Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
title Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
title_full Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
title_fullStr Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
title_full_unstemmed Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
title_short Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
title_sort placenta accreta spectrum prenatal diagnosis performance: are ultrasound false-positive results acceptable in limited-resources settings?
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9948072/
https://www.ncbi.nlm.nih.gov/pubmed/36067797
http://dx.doi.org/10.1055/s-0042-1751061
work_keys_str_mv AT nietocalvachealbarojose placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT benavidescalvachejuanpablo placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT hidalgoalejandra placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT padillanatalia placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT lopeztenoriojaime placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT victoriaalejandro placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT rengifomartin placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT mejiamauricio placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT vergaragalliadilinamaria placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT sinisterradiazstivenernesto placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT mayajuliana placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT zambranomariaandrea placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings
AT burgoslunajuanmanuel placentaaccretaspectrumprenataldiagnosisperformanceareultrasoundfalsepositiveresultsacceptableinlimitedresourcessettings