Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application

PURPOSE: To develop a model-based reconstruction technique for diffusion quantification based on accelerated two-dimensional echo planar data, obtained with multiple b-weightings. In combination with a dedicated undersampling pattern, acceleration factors above three were proven feasible in a clinic...

Descripción completa

Detalles Bibliográficos
Autores principales: Hüfken, Thomas, Arbogast, Jannik M., Bracher, Anna-Katinka, Beer, Meinrad, Neubauer, Henning, Rasche, Volker
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9948881/
https://www.ncbi.nlm.nih.gov/pubmed/34175164
http://dx.doi.org/10.1016/j.zemedi.2021.04.004
_version_ 1784892873622159360
author Hüfken, Thomas
Arbogast, Jannik M.
Bracher, Anna-Katinka
Beer, Meinrad
Neubauer, Henning
Rasche, Volker
author_facet Hüfken, Thomas
Arbogast, Jannik M.
Bracher, Anna-Katinka
Beer, Meinrad
Neubauer, Henning
Rasche, Volker
author_sort Hüfken, Thomas
collection PubMed
description PURPOSE: To develop a model-based reconstruction technique for diffusion quantification based on accelerated two-dimensional echo planar data, obtained with multiple b-weightings. In combination with a dedicated undersampling pattern, acceleration factors above three were proven feasible in a clinical setting. METHODS: The proposed model-based method minimizes a cost function considering the l(2)-norm of the difference between the Fourier transformation of a synthetic diffusion-model-generated k-space and the measured k-space data. Further regularization is performed by introduction of a total variation (TV) constraint to the cost function. Acceleration is achieved by a non-random undersampling pattern using acceleration factors that correspond to the total number of b-values. A rectangular region of variable size, centered in k-space, remains fully sampled for correction of phase variations, introduced by the different diffusion-encoding strengths. RESULTS: Qualitative analysis of the resulting images (S(0) and ADC) demonstrates the potential of the suggested undersampling pattern in combination with a model-based iterative reconstruction. An edge analysis highlights the preservation of high-frequency information for all investigated undersampling factors. In comparison to a conventional SENSE-accelerated reconstruction, the quantitative analysis of the ADC maps revealed a significantly (P < 0.05) superior performance of the suggested technique, enabling acceleration factors of R = 3.65 without compromising diffusion data fidelity. CONCLUSION: The presented work shows the potential of model-based ADC quantification, which, in combination with a suited undersampling pattern for multiple b-values, enables more than three-fold acceleration using two-dimensional EPI without sacrificing ADC fidelity.
format Online
Article
Text
id pubmed-9948881
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99488812023-02-23 Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application Hüfken, Thomas Arbogast, Jannik M. Bracher, Anna-Katinka Beer, Meinrad Neubauer, Henning Rasche, Volker Z Med Phys Short Communication PURPOSE: To develop a model-based reconstruction technique for diffusion quantification based on accelerated two-dimensional echo planar data, obtained with multiple b-weightings. In combination with a dedicated undersampling pattern, acceleration factors above three were proven feasible in a clinical setting. METHODS: The proposed model-based method minimizes a cost function considering the l(2)-norm of the difference between the Fourier transformation of a synthetic diffusion-model-generated k-space and the measured k-space data. Further regularization is performed by introduction of a total variation (TV) constraint to the cost function. Acceleration is achieved by a non-random undersampling pattern using acceleration factors that correspond to the total number of b-values. A rectangular region of variable size, centered in k-space, remains fully sampled for correction of phase variations, introduced by the different diffusion-encoding strengths. RESULTS: Qualitative analysis of the resulting images (S(0) and ADC) demonstrates the potential of the suggested undersampling pattern in combination with a model-based iterative reconstruction. An edge analysis highlights the preservation of high-frequency information for all investigated undersampling factors. In comparison to a conventional SENSE-accelerated reconstruction, the quantitative analysis of the ADC maps revealed a significantly (P < 0.05) superior performance of the suggested technique, enabling acceleration factors of R = 3.65 without compromising diffusion data fidelity. CONCLUSION: The presented work shows the potential of model-based ADC quantification, which, in combination with a suited undersampling pattern for multiple b-values, enables more than three-fold acceleration using two-dimensional EPI without sacrificing ADC fidelity. Elsevier 2021-06-24 /pmc/articles/PMC9948881/ /pubmed/34175164 http://dx.doi.org/10.1016/j.zemedi.2021.04.004 Text en © 2021 The Author(s). Published by Elsevier GmbH on behalf of DGMP, ÖGMP and SSRMP. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Short Communication
Hüfken, Thomas
Arbogast, Jannik M.
Bracher, Anna-Katinka
Beer, Meinrad
Neubauer, Henning
Rasche, Volker
Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application
title Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application
title_full Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application
title_fullStr Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application
title_full_unstemmed Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application
title_short Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application
title_sort accelerated model-based quantitative diffusion mri: a feasibility study for musculoskeletal application
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9948881/
https://www.ncbi.nlm.nih.gov/pubmed/34175164
http://dx.doi.org/10.1016/j.zemedi.2021.04.004
work_keys_str_mv AT hufkenthomas acceleratedmodelbasedquantitativediffusionmriafeasibilitystudyformusculoskeletalapplication
AT arbogastjannikm acceleratedmodelbasedquantitativediffusionmriafeasibilitystudyformusculoskeletalapplication
AT bracherannakatinka acceleratedmodelbasedquantitativediffusionmriafeasibilitystudyformusculoskeletalapplication
AT beermeinrad acceleratedmodelbasedquantitativediffusionmriafeasibilitystudyformusculoskeletalapplication
AT neubauerhenning acceleratedmodelbasedquantitativediffusionmriafeasibilitystudyformusculoskeletalapplication
AT raschevolker acceleratedmodelbasedquantitativediffusionmriafeasibilitystudyformusculoskeletalapplication